Page 171

NDA-24306 CHAPTER 3
Page 143
Revision 1.0
Figure 010-20  Inter-frame Alarm Bus Cable Connection for IMG0-IMG1
NAP-200-010
Sheet 39/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the inter-frame alarm bus cables between
IMG0 and IMG1 as shown below.
IMG 1
IMG 0
TOPU
TSWM0
Note
LPM
REAR VIEWFRONT VIEW
TOPU
(1)
(2)
PIM 0PIM 1
(3)
PIM 2
FA N U
PIM 3
PIM 0
DSPPZ-DK223
EMAFHLED1
MUSIC
ALM1
EMA
Note:Also to EMA connector in TSWM1 of IMG2. 

Page 172

CHAPTER 3 NDA-24306
Page 144
Revision 1.0
NAP-200-010
Sheet 40/73
Cable Connections
Table 010-12  Inter-frame Alarm Bus Cable Connection for IMG0-IMG1
No.FROM TO
CABLE NAME REMARKS
UNIT/
MODULECONNECTOR 
NAMEUNIT/
MODULECONNECTOR 
NAME
(1) LPM LED1TOPU
(IMG1)DSPM 16PH LED CA-A
(2) LPM ALM1 TSWM0 EMA SP ALM CA
(3) LPM MUSIC TSWM0 EMAFH 16PH STD CA-F
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required 

Page 173

NDA-24306 CHAPTER 3
Page 145
Revision 1.0
Figure 010-21  Inter-frame ISA Bus Cable Connection for IMG0-IMG2
NAP-200-010
Sheet 41/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
TOPU
LPM
BASEU
00 01 02 03 04 05 06 00 01 02 03 04 05 06PZ-GT20
CN
PZ-GT20
CN
FRONT VIEW
(GT1)
(GT0)
IOP1 IOP0
REAR VIEWIMG0 IMG2
TSWM1TOPU
BASEU
CPU0 CPU1
34PH 50AL CA-B
34PH 50AL CA-B
Connect the inter-frame ISA bus cables between IMG0 and IMG2 as shown below. Note that the dotted...

Page 174

CHAPTER 3 NDA-24306
Page 146
Revision 1.0
Figure 010-22  Inter-frame Alarm Bus Cable Connection for IMG0-IMG2
NAP-200-010
Sheet 42/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the inter-frame Alarm bus cables between IMG0 and IMG2 as shown below.
Note:Also to EMA connector in TSWM0 of IMG1.
REAR VIEWREAR VIEW TSWM1
LPM
TOPU
LED2
ALM2
DSPM   PZ-DK223IMG2 IMG0
16PH LED CA-B
EMA
SP ALM CATO P U
Note 

Page 175

NDA-24306 CHAPTER 3
Page 147
Revision 1.0
Figure 010-23  Inter-frame Alarm Bus Cable Connection for IMG0-IMG3
NAP-200-010
Sheet 43/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the inter-frame Alarm bus cables between IMG0 and IMG3 of LN as shown below.
REAR VIEWREAR VIEW DUMMYLPM TOPU
LED3
ALM3
IMG3IMG0
PZ-DK223
16PH LED CA-B
16PH ALM CA-B
PIM0
TOPUDSPM
ALMA 

Page 176

CHAPTER 3 NDA-24306
Page 148
Revision 1.0
Figure 010-24  Inter-frame Bus Cable Connection for IMG1-IMG2
NAP-200-010
Sheet 44/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Note:Also to ALM2 connector in LPM of IMG0. Connect the inter-frame bus cables between IMG1 and IMG2 of LN as shown below. The dotted line indicates
the bus cable connection for a dual-system.
REAR VIEW TSWM1
Note
PLOCLK0 TO P U
21 23IMG2
REAR VIEWTSWM0
PLOCLK0TOPU
21 23IMG1
PLO-CLK CA-A...

Page 177

NDA-24306 CHAPTER 3
Page 149
Revision 1.0
Figure 010-25  Inter-frame Bus Cable Connection for IMG2-IMG3
NAP-200-010
Sheet 45/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the inter-frame bus cables between IMG2 and IMG3 of LN as shown below. Note that the dotted lines
indicate the bus cable connection for a dual-system.
MUX010 IMG2
IMG3
MUX011 MUX012 MUX013
MUX113(TSW11) (TSW01)
MUX112
MUX111
MUX110
TSWM1PIM0 PIM1 PIM2 PIM3
BASEUDUMMY PIM0 PIM1 PIM2...

Page 178

CHAPTER 3 NDA-24306
Page 150
Revision 1.0
NAP-200-010
Sheet 46/73
Cable Connections
Table 010-13  Inter-frame Bus Cable Connection for IMG2-IMG3
No.FROM TO
CABLE NAME REMARKS
UNIT/
MODULECONNECTOR 
NAMEUNIT/
MODULECONNECTOR 
NAME
(1) TSWM MUX010PIM0 
(IMG3)MUX (slot 13) 34PH MT24 TSW CA-FWhen IMG3 exists in 
LNn
(2) TSWM MUX011PIM1 
(IMG3)MUX (slot 13) 34PH MT24 TSW CA-FWhen PIM1 exists in 
IMG3 of LNn
(3) TSWM MUX012PIM2 
(IMG3)MUX (slot 13) 34PH MT24 TSW CA-GWhen PIM2 exists in 
IMG3 of LNn
(4) TSWM...

Page 179

NDA-24306 CHAPTER 3
Page 151
Revision 1.0
3. PCM AND ALARM CABLE CONNECTIONS BETWEEN ISW AND EACH LN
This section explains how to run the frame-to-frame PCM and alarm bus cables between ISW and LN. 
According to your system configuration, connect all the necessary cables as shown below:
NAP-200-010
Sheet 47/73
Cable Connections
START
Confirm connector locations Referring to Figures 010-2 and 010-4, confirm the 
locations of the connectors into which the cables are 
inserted.
Connection of Inter-frame...

Page 180

CHAPTER 3 NDA-24306
Page 152
Revision 1.0
Figure 010-26  Inter-frame Cable Connection for ISW-LN0, IMG0
NAP-200-010
Sheet 48/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the inter-frame alarm bus cable between ISW and IMG0 of LN0 as shown below. 
FRONT VIEWFRONT VIEW
LN0/IMG0
PZ-PW92
PZ-PW92
CPU0
CPU1
00
0000
CN0CN0
ISW
LPM PIM0
LPM
BASEUTO P U
TOPU
ISWM
00
MT24 MISC CA-C
BASEU
PH-M22(MMC) PH-M22(MMC) 
Start reading NEC Neax 2400 Ipx Installation Manual

Related Manuals for NEC Neax 2400 Ipx Installation Manual

All NEC manuals