NDA-24306 CHAPTER 3 Page 183 Revision 1.0 Figure 012-2 Cable Routing of Circuit Card Front Cable NAP-200-012 Sheet 5/13 Cable Running from the PBX to MDF, ATTCON, MAT and SMDR Cable Duct SIDE VIEW FRONT VIEWCable Cable HoleCircuit Card Front Connector Circuit Card Up to three circuit card front cables can be run through the cable hole.Six circuit card front cables can be accommodated; three on the left side, and three on the right side.
Page 212
CHAPTER 3 NDA-24306 Page 184 Revision 1.0 2. CABLE RUNNING FROM THE PBX TO THE MAT AND SMDR NAP-200-012 Sheet 6/13 Cable Running from the PBX to MDF, ATTCON, MAT and SMDR START MAT (Refer to NAP-200-016) Referring to NAP-200-016, connect 68PH S 2 PORTS CA-A and the installation cable (25P). At the PBX side, confirm the connector name on the LPM backplane, then run 68PH S 2 PORTS CA-A up to the connector position. At the MAT side, run RS-232-CA “0” up to the MAT. SMDR (Refer to NAP-200-017) Referring...
Page 213
NDA-24306 CHAPTER 3 Page 185 Revision 1.0 3. CONNECTIONS AT THE PBX SIDE 4. CABLE TYING AT THE PBX NAP-200-012 Sheet 7/13 Cable Running from the PBX to MDF, ATTCON, MAT and SMDR START LT Connectors Confirm each connector name on the backplane and the corresponding LT connector, then connect the two. MISC0A Connector Connect the 68PH EXMISC CA cable to the MISC0A rear connector on the LPM backplane. NCU Connectors Connect the NCU cable to the connector on the front of the PFT card. IOC Connectors...
Page 214
CHAPTER 3 NDA-24306 Page 186 Revision 1.0 Figure 012-3 Example of Cable Tying Using Tie-Wrap NAP-200-012 Sheet 8/13 Cable Running from the PBX to MDF, ATTCON, MAT and SMDR Backplane LT 6 PL O LT3 LT 2 L T5L T4 LT 0 LT 1 REAR SIDETIE-WRAP
Page 215
NDA-24306 CHAPTER 3 Page 187 Revision 1.0 5. TERMINATION OF THE CABLES BETWEEN THE PBX AND THE MDF OR ATTCON ONTO THE CABLE SUPPORT ASSEMBLY NAP-200-012 Sheet 9/13 Cable Running from the PBX to MDF, ATTCON, MAT and SMDR START Remove of the Cable Support Assembly.Remove the Cable Support Assembly from the BASEU. (See Figure 012-4.) Peel the cable cover Referring to Table 012-1, confirm the cable terminating locations on the Cable Support Assembly. Per the cable terminating locations, peel the cable...
Page 216
CHAPTER 3 NDA-24306 Page 188 Revision 1.0 Figure 012-4 Cable Support Assembly NAP-200-012 Sheet 10/13 Cable Running from the PBX to MDF, ATTCON, MAT and SMDR AB C D (LPM, TSWM or APM) REAR VIEW(BASEU) CABLE SUPPORT ASSEMBLY FRONT SIDE VIEW (LPM, TSWM or APM)
Page 217
NDA-24306 CHAPTER 3 Page 189 Revision 1.0 Note:For LPM only. NAP-200-012 Sheet 11/13 Cable Running from the PBX to MDF, ATTCON, MAT and SMDR Table 012-1 Cable Support Assembly BACKPLANE CABLE SUPPORT No.USE REMARKS MODULE CONNECTOR NAME LPM/ TSWMMISCnA, MISCnB Afor I/O Equipment (MAT, Printer, etc.)Spare cable (15 cables) are to be used as Cable Support Assembly extra cables. The number of cables for the whole system is limited to maximum 100. MISC0A Note Afor Alarm Indicating Panel, etc. A...
Page 218
CHAPTER 3 NDA-24306 Page 190 Revision 1.0 Figure 012-5 Clamp Winding NAP-200-012 Sheet 12/13 Cable Running from the PBX to MDF, ATTCON, MAT and SMDR Shield cableApprox. 18 mm (0.72 inch)CLAMP (M-398902)
Page 219
NDA-24306 CHAPTER 3 Page 191 Revision 1.0 Figure 012-6 Termination of Installation Cables NAP-200-012 Sheet 13/13 Cable Running from the PBX to MDF, ATTCON, MAT and SMDR (FRONT) CABLE CABLE SUPPORT ASSEMBLY CABLE SUPPORT ASSEMBLY CLAMP CABLEPANHEAD SCREW (PL-C, P, B, MS 4X8X3 GF)
Page 220
CHAPTE R 3 NDA-2 4306 P ag e 192 R evis io n 1.0 T his NA P exp la ins the p roc edur es f or t e rm in ating ca bles at t h e M DF. CAUTION : When t erm ina ti n g Ca ble s to the MD F, t h e line /trunk c ir c uit c a rd sh ould e x te nd about 50 mm (2 in ch es) from the module, and must not contact the backplane connector. NAP-200-013 Sheet 1/1 Termination of Cables on MDF (Wire Accommodation of Each Cable) START Cable trying at the MDF Secure the CHAMP Connector cables,...