Figure 010-27  Inter-frame Cable Connection for ISW-LN1, IMG0
NAP-200-010
Sheet 49/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the inter-frame alarm bus cable between ISW and IMG0 of LN1 as shown below. 
FRONT VIEWFRONT VIEW
LN1/IMG0
00
CN1CN0
ISW
LPM LPM
BASEUTO P U
TOPU
ISWM
00
MT24 MISC CA-D
BASEU
PIM0
PZ-PW92
PZ-PW92
CPU1
CPU000
00
PH-M22 (MMC) PH-M22 (MMC) 

Page 182

CHAPTER 3 NDA-24306
Page 154
Revision 1.0
Figure 010-28  Inter-frame Cable Connection for ISW-LN2, IMG0
NAP-200-010
Sheet 50/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the inter-frame alarm bus cable between ISW and IMG0 of LN2 as shown below. 
Note:This cable connection is required if LN2 exists in your system.
FRONT VIEWFRONT VIEW
LN2/IMG0
00
ISW
LPM LPM
BASEUTOPU
TO P U
ISWM
00
MT24 MISC CA-D
BASEU
PH-M22 (MMC)PH-M22 (MMC)PZ-PW92 PZ-PW92
CPU1...

Page 183

NDA-24306 CHAPTER 3
Page 155
Revision 1.0
Figure 010-29  Inter-frame Cable Connection for ISW-LN3, IMG0
NAP-200-010
Sheet 51/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the inter-frame alarm bus cable between ISW and IMG0 of LN3 as shown below. 
Note:This cable connection is required if LN3 exists in your system.
FRONT VIEWFRONT VIEW
LN3/IMG0
PZ-PW92
PZ-PW92
CPU1
CPU0
00
ISW
LPM PIM0
LPM
BASEUTO P U
TO P U
ISWM
00
MT24 MISC CA-F
BASEU
PH-M22(MMC)...

Page 184

CHAPTER 3 NDA-24306
Page 156
Revision 1.0
Figure 010-30  Inter-frame Bus Cable Connection for ISW-LN0, IMG1
NAP-200-010
Sheet 52/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the inter-frame bus cables between ISW and IMG1 of LN0 as shown below. Note that the dotted lines
indicate the bus cable connection for a dual-system.
TOPU
ISWM
LPM
BASEU
REAR VIEW
ISW
REAR VIEW TSWM0
LN0/IMG1
EXCLK0
EXCLK1
TSW000 TSW001
TSW002
TSW003 TSW004 TSW005
TSW006...

Page 185

NDA-24306 CHAPTER 3
Page 157
Revision 1.0
NAP-200-010
Sheet 53/73
Cable Connections
Table 010-14  Inter-frame Bus Cable Connection for ISW-LN0, IMG1
No.FROM TO
CABLE NAME REMARKS
UNIT/
MODULECONNECTOR 
NAMEUNIT/
MODULECONNECTOR 
NAME
(1)ISWM 
(slot 04)TSW000TSWM0
(slot 14)MUX020 ISW-LN TSW-CA-A
(2)ISWM 
(slot 04)TSW001TSWM0
(slot 14)MUX021 ISW-LN TSW-CA-A
(3)ISWM 
(slot 04)TSW002TSWM0
(slot 14)MUX022 ISW-LN TSW-CA-A
(4)ISWM 
(slot 04)TSW003TSWM0
(slot 14)MUX023 ISW-LN TSW-CA-A
(5)ISWM 
(slot...

Page 186

CHAPTER 3 NDA-24306
Page 158
Revision 1.0
Figure 010-31  Inter-frame Bus Cable Connection for ISW-LN0, IMG2
NAP-200-010
Sheet 54/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the inter-frame bus cables between ISW and IMG2 of LN0 as shown below. Note that the dotted lines
indicate the bus cable connection for a dual-system.
TOPU
ISWM
LPM
BASEU
REAR VIEW
ISW
REAR VIEW TSWM1
LN0/IMG2
TSW008 TSW009 TSW00A TSW00B TSW00C TSW00D TSW00E
TSW00F
TSW108 TSW109...

Page 187

NDA-24306 CHAPTER 3
Page 159
Revision 1.0
NAP-200-010
Sheet 55/73
Cable Connections
Table 010-15  Inter-frame Bus Cable Connection for ISW-LN0, IMG2
No.FROM TO
CABLE NAME REMARKS
UNIT/
MODULECONNECTOR 
NAMEUNIT/
MODULECONNECTOR 
NAME
(1)ISWM 
(slot 04)TSW008TSWM1
(slot 14)MUX020 ISW-LN TSW-CA-BWhen IMG2 exists in 
LN0
(2)ISWM 
(slot 04)TSW009TSWM1
(slot 14)MUX021 ISW-LN TSW-CA-BWhen PIM1 exists in 
IMG2 of LN0
(3)ISWM 
(slot 04)TSW00ATSWM1
(slot 14)MUX022 ISW-LN TSW-CA-BWhen PIM2 exists in 
IMG2 of LN0...

Page 188

CHAPTER 3 NDA-24306
Page 160
Revision 1.0
Figure 010-32  Inter-frame Bus Cable Connection for ISW-LN1, IMG1
NAP-200-010
Sheet 56/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
TO P U
ISWM
LPM
BASEU
REAR VIEW
ISW
REAR VIEW TSWM0
LN1/IMG1
EXCLK0
EXCLK1
TSW010 TSW011
TSW012
TSW013 TSW014 TSW015
TSW016
TSW017
TSW110 TSW111
TSW112
TSW113 TSW114 TSW115
TSW116
TSW117
MUX020 MUX033
MUX132 MUX133CLK01 CLK11
15
14 15 18 19
1208 05
MUX030MUX031
MUX130MUX131
MUX021...

Page 189

NDA-24306 CHAPTER 3
Page 161
Revision 1.0
NAP-200-010
Sheet 57/73
Cable Connections
Table 010-16  Inter-frame Bus Cable Connection for ISW-LN1, IMG1
No.FROM TO
CABLE NAME REMARKS
UNIT/
MODULECONNECTOR 
NAMEUNIT/
MODULECONNECTOR 
NAME
(1)ISWM 
(slot 05)TSW010TSWM0
(slot 14)MUX020 ISW-LN TSW-CA-G
(2)ISWM 
(slot 05)TSW011TSWM0
(slot 14)MUX021 ISW-LN TSW-CA-G
(3)ISWM 
(slot 05)TSW012TSWM0
(slot 14)MUX022 ISW-LN TSW-CA-G
(4)ISWM 
(slot 05)TSW013TSWM0
(slot 14)MUX023 ISW-LN TSW-CA-G
(5)ISWM 
(slot...

Page 190

CHAPTER 3 NDA-24306
Page 162
Revision 1.0
Figure 010-33  Inter-frame Bus Cable Connection for ISW-LN1, IMG2
NAP-200-010
Sheet 58/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the inter-frame bus cables between ISW and IMG2 of LN1 as shown below. Note that the dotted lines
indicate the bus cable connection for a dual-system.
TO P U
ISWM
LPM
BASEU
REAR VIEW
ISW
REAR VIEW SWM1
LN1/IMG2
MUX020 MUX132 MUX133TSW118 TSW119
TSW11A
TSW11B TSW11C TSW11D...
Start reading NEC Neax 2400 Ipx Installation Manual

Related Manuals for NEC Neax 2400 Ipx Installation Manual

All NEC manuals