Home > NEC > Communications System > NEC Neax 2400 Ipx Installation Manual

NEC Neax 2400 Ipx Installation Manual

Here you can view all the pages of manual NEC Neax 2400 Ipx Installation Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 151

NDA-24306 CHAPTER 3
Page 123
Revision 1.0
NAP-200-010
Sheet 19/73
Cable Connections
Table 010-2  Internal Power Cable Connection for ISW
No.TO FROM
CABLE NAME REMARKS
UNIT/
MODULECONNECTOR 
NAMEUNIT/
MODULECONNECTOR 
NAME
(1)BASEU
(PZ-M371)PA0 LPM PWR0 IN PWR 4P-2P PWR CA-A
(2)BASEU
(PZ-M371)PB0 LPM PWR1 IN PWR 4P-2P PWR CA-BFor dual
configuration
(3)BASEU
(PZ-M371)PA1 ISWM PWRA 4P PWR CA-C
(4)BASEU
(PZ-M371)PB1 ISWM PWRB 4P PWR CA-DFor dual
configuration
(5) LPM PWR0 OUT PWR LPM PWRA0/B0 6P-(4P-3P) PWR...

Page 152

CHAPTER 3 NDA-24306
Page 124
Revision 1.0
Figure 010-10  Internal Power Cable Connection for IMG0
NAP-200-010
Sheet 20/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the internal power cables for IMG0 of each LN as shown below. Note that the dotted lines indicate power
cables for a dual-system.
FRONT VIEW REAR VIEW
PIM 1PIM 1 FA N UFA N U PIM 2
PIM 2 PIM 3TOPU
LPMLPM TOPU
PIM 3
PIM 0
BASEU
(1)(2)(3)(4)(5)
(6)(7)(8)(9)(10)(12)(14) (15)(16) (18)
00
01...

Page 153

NDA-24306 CHAPTER 3
Page 125
Revision 1.0
NAP-200-010
Sheet 21/73
Cable Connections
Table 010-3  Internal Power Cable Connection for IMG0
No.TO FROM
CABLE NAME REMARKS
UNIT/
MODULECONNECTOR 
NAMEUNIT/
MODULECONNECTOR
NAME
(1) LPM INPWR BASEU PA0 4P-2P PWR CA-AFor LN0/1 and if LN2/3 exist
(2) LPM INPWR BASEU PB0 4P-2P PWR CA-BFor dual configuration
For LN0/1 and if LN2/3 exist
(3) BASEU PA1 PIM0 PWRA 4P PWR CA-CFor LN0/1 and if LN2/3 exist
(4) BASEU PB1 PIM0 PWRB 4P PWR CA-DFor dual configuration
For...

Page 154

CHAPTER 3 NDA-24306
Page 126
Revision 1.0
Figure 010-11  Internal Power Cable Connection for IMG1/2
NAP-200-010
Sheet 22/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the internal power cables for IMG1 and IMG2 of each LN as shown below. Note that the dotted lines
indicate power cables for a dual-system.
00
01
 PWR
00
01
 PWR
00
01
 PWR
00 01
 PWR
0203
 PWR
0203
 PWR
02
03
 PWR
02
03
 PWR
PZ-M371
 (1) (9)  (11)
 (2) (8) (10)
 (12) (14)
 (16)
 (18)...

Page 155

NDA-24306 CHAPTER 3
Page 127
Revision 1.0
NAP-200-010
Sheet 23/73
Cable Connections
Table 010-4  Internal Power Cable Connection for IMG1/2
No.TO FROM
CABLE NAME REMARKS
UNIT/
MODULECONNECTOR
NAMEUNIT/
MODULECONNECTOR
NAME
(1) BASEU PA0 TSWM0/1 PWR A 4P PWR CA-AWhen IMG1/2 exists in LNn
(2) BASEU PB0 TSWM0/1 PWR B 4P PWR CA-BFor dual configuration
When IMG1/2 exists in LNn
(3) BASEU PA1 PIM0 PWR A 4P PWR CA-CWhen IMG1/2 exists in LNn
(4) BASEU PB1 PIM0 PWR B 4P PWR CA-DFor dual configuration
When IMG1/2...

Page 156

CHAPTER 3 NDA-24306
Page 128
Revision 1.0
Figure 010-12  Internal Power Cable Connection for IMG3
NAP-200-010
Sheet 24/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the internal power cables for IMG3 of each LN as shown below. Note that the dotted lines indicate power
cables for a dual-system.
PWR
PWR
PWR
00 01
PWR
PWR
PWR
PWR
02 03
00 01 02 03
00 01 02 03
00 01 02 03
PWR
PZ-M371
 (1) (3)
 (5) (7)  (9)
 (2) (4) (6) (8)
 (10)  (12)
 (14)
PIM 1PIM 1 FA...

Page 157

NDA-24306 CHAPTER 3
Page 129
Revision 1.0
NAP-200-010
Sheet 25/73
Cable Connections
Table 010-5  Internal Power Cable Connection for IMG3
No.TO FROM
CABLE NAME REMARKS
UNIT/
MODULECONNECTOR 
NAMEUNIT/
MODULECONNECTOR 
NAME
(1) BASEU PA1 PIM0 PWR A 4P PWR CA-CWhen IMG3 exists in LNn
(2) BASEU PB1 PIM0 PWR B 4P PWR CA-DFor dual configuration
When IMG3 exists in LNn
(3) BASEU PA2 PIM1 PWR A 4P PWR CA-EWhen PIM1 exists in IMG3 
of LNn
(4) BASEU PB2 PIM1 PWR B 4P PWR CA-F
For dual configuration
When PIM1...

Page 158

CHAPTER 3 NDA-24306
Page 130
Revision 1.0
Run the internal bus cables for ISW and each IMG of LN, referring to Figures 010-13 through 010-17.
Figure 010-13  Internal Bus Cable Connection for ISW
NAP-200-010
Sheet 26/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
REAR VIEW FRONT VIEW
TO P U
ISWM
TIORES1TIORES0
EMAFHALMA
LPM
BASEUTOPU
ISWM
LPM
BASEU (5)(9)(10)
(3)
(4)
(8)
(11)(1)
(2)
(6)
(7)
KEY PZ-DK227
PZ-PW92
CPU 1
CPU 0
M  T
PZ-GT13
PALM
PZ-PW92PALM
KEY
CN...

Page 159

NDA-24306 CHAPTER 3
Page 131
Revision 1.0
NAP-200-010
Sheet 27/73
Cable Connections
Table 010-6  Internal Bus Cable Connection for ISW
No.TO FROM
CABLE NAME REMARKS
UNIT/
MODULECONNECTOR 
NAMEUNIT/
MODULECONNECTOR 
NAME
(1) LPM PALM LPM PALM0 10AL-(110) FLT CA
(2) LPM PALM LPM PALM1 10AL-(130) FLT CA
For dual configuration
(3) LPM KEY TOPUKEY 
(PZ-DK227)10AL-(400) FLT CA
(4) LPM ALM1 ISWM ALMA 16PH ALM CA-A
(5) LPM DSP TOPUDSPL 
(PZ-DK223)20AL-(270) FLT CA
(6)LPM
(ISAGT0)CN-M LPM BUS0 EXGT BUS CA-A...

Page 160

CHAPTER 3 NDA-24306
Page 132
Revision 1.0
Figure 010-14  Internal Bus Cable Connection for IMG0
NAP-200-010
Sheet 28/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the internal bus cables for IMG0 of all the LN as shown below. Note that the dotted line indicates the
bus cable for a dual-system.
(5)
(4)
(1)(3)(2)
TO PU
PIM3
PIM2
FA N U
PIM1
PIM0
LPM
BASEU
REAR VIEW
TO PU
PIM3
PIM2
FA N U
PIM1
PIM0
LPM
BASEU
FRONTVIEW
ALMA
(8)ALMB
ALMA
ALMB
ALMA
ALMA...
Start reading NEC Neax 2400 Ipx Installation Manual

Related Manuals for NEC Neax 2400 Ipx Installation Manual

All NEC manuals