This NAP explains the following work items:
 Extraction of Mounted Circuit Cards
 Mounting of Circuit Cards
 Setting of Switch Positions on Circuit Cards
 Installation of CPR
1. PRECAUTIONS
1.1 Protection Against Static Electricity
When setting switches on circuit cards, use a Portable Field Service Grounding Kit to prevent damage to static-
sensitive components.
Example:    3M Model 8012, consists of:
2 × 2 VELOSTAT 
® Wo r k  M a t
 15 ft. Ground Cord
...

Page 122

CHAPTER 3 NDA-24306
Pag e 9 4
Revision 1.0
2. EXTRACTION OF MOUNTED CIRCUIT CARDS
NAP-200-009
Sheet 2/12
Setting of Switch Positions and Mounting 
of the Circuit Cards
START
Remove the Card Stopper Referring to Figure 009-1, remove the card stopper from 
the module.
Extract Circuit Cards Referring to Figure 009-2, pull the card puller tabs in the 
direction indicated by the arrow. The card will release 
from the connector and can then be removed.
Pull the card out about 50 mm (2 inches) from the edge 
of...

Page 123

NDA-24306 CHAPTER 3
Page 95
Revision 1.0
Figure 009-1  Removal of Card Stopper
NAP-200-009
Sheet 3/12
Setting of Switch Positions and Mounting 
of the Circuit Cards
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
CARD STOPPER
PAN HEAD SCREW (M3,8mm length)
SPRING WASHER (M3)
PLAIN WASHER (M3)
Remove the card stopper from the 
module using a Phillips-head screwdriver. (PL-C.P.l. MSx3x8x15BF) 

Page 124

CHAPTER 3 NDA-24306
Pag e 9 6
Revision 1.0
3. MOUNTING OF CIRCUIT CARDS
NAP-200-009
Sheet 4/12
Setting of Switch Positions and Mounting 
of the Circuit Cards
START
Unpacking the Circuit Cards Unpack each circuit card and remove it from its 
polyethylene bag.
Clean the connector portion of the 
Circuit CardsWipe the connector portion clean using a soft cloth 
moistened with pure trichloroethylene or methanol 
(medical alcohol). Make sure that no lint or dust 
remains on the connector after cleaning....

Page 125

NDA-24306 CHAPTER 3
Page 97
Revision 1.0
4. SETTING OF SWITCH POSITIONS ON CIRCUIT CARDS
NAP-200-009
Sheet 5/12
Setting of Switch Positions and Mounting 
of the Circuit Cards
START
Extracting the Circuit Cards from the 
ModuleExtract one circuit card requiring switch setting from 
the module.
Place the extracted card onto the anti-static sheet.
Perform switch setting Set the required switches according to the Switch 
Setting Sheets in the Circuit Card Manual.
Mounting of Circuit Cards After the switches...

Page 126

CHAPTER 3 NDA-24306
Pag e 9 8
Revision 1.0
NAP-200-009
Sheet 6/12
Setting of Switch Positions and Mounting 
of the Circuit Cards
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
About 50 mm 
(2 inches)
About 50 mm 
(2 inches)
CIRCUIT 
CARDS
CARD 
PULLER 
TAB
Figure 009-2  Extraction of Circuit CardsFigure 009-3  Circuit Card Mounting (Partial Insertion) 

Page 127

NDA-24306 CHAPTER 3
Page 99
Revision 1.0
5. INSTALLATION OF CPR
This section explains the procedure to install the CPR into the LPM of each Local Node (LN) and ISW. Perform
the following for all the CPR (CPR0/1) of each LN and ISW.
1. Using the Phillips Screwdriver, remove the four + eight screws. Then, detach the front panel and top cover
from the CPR. (Refer to Figure 009-4.)
Figure 009-4  Removing Front Panel and Top Cover from CPR
NAP-200-009
Sheet 7/12
Setting of Switch Positions and Mounting 
of...

Page 128

CHAPTER 3 NDA-24306
Page 100
Revision 1.0
2. Depending on the system configuration, insert the ISAGT (PZ-GT13/PZ-GT20) and LANI (PZ-PC19)
cards into the following slots of the CPR (refer to Figure 009-5):
ISAGT (PZ-GT13)→slot 6 (ISA) (Fixed)
ISAGT (PZ-GT20)→slot 5 (ISA) (When the LN has 3 or 4 IMGs) 
Note
LANI →Slot 0 (PCI) (For Fusion link)
LANI →Slot 1 (PCI) (When connecting MAT via 10-BASE T and PCI buses)
LANI →Slot 3 (PCI) (When LANI for Fusion link is in dual configuration)
Note:This card is...

Page 129

NDA-24306 CHAPTER 3
Page 101
Revision 1.0
3. Attach the top cover and front panel again by fastening the removed screws. (Refer to Figure 009-6.)
Figure 009-6  Reattaching CPR Top Cover and Front Panel
NAP-200-009
Sheet 9/12
Setting of Switch Positions and Mounting 
of the Circuit Cards
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
Top Cover
CPRFront Panel
After mounting the ISAGT/LANI cards, reattach the top cover by tightening the eight screws.
Then, also attach the Front Panel by...

Page 130

CHAPTER 3 NDA-24306
Page 102
Revision 1.0
4. After turning “ON” the MBR key on the DSP of the new CPR, insert the new CPR into the LPM. Then,
fasten the four screws. (Refer to Figure 009-7.)
Figure 009-7  Accommodating New CPR into LPM
NAP-200-009
Sheet 10/12
Setting of Switch Positions and Mounting 
of the Circuit Cards
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
As shown in the figure below, insert the new CPR into the LPM. Then, fasten the four screws. 
LPM
CPR 