Page 161

NDA-24306 CHAPTER 3
Page 133
Revision 1.0
NAP-200-010
Sheet 29/73
Cable Connections
Table 010-7  Internal Bus Cable Connection for IMG0
No.TO FROM
CABLE NAME REMARKS
UNIT/
MODULECONNECTOR 
NAMEUNIT/
MODULECONNECTOR 
NAME
(1)LPM
(ISAGT0)CN-M LPM BUS0 EXGT BUS CA-AFor LN0/1 and if LN2/3 
exist
(2)LPM 
(ISAGT1)CN-M LPM BUS1 EXGT BUS CA-A
For dual configuration
For LN0/1 and if LN2/3 
exist
(3) MMC KEY TOPU KEY 10AL-(400) FLT CAFor LN0/1 and if LN2/3 
exist
(4) LPM MISC0B/KEY LPM EXALM 68PH KEY CAFor LN0/1...

Page 162

CHAPTER 3 NDA-24306
Page 134
Revision 1.0
Figure 010-15  Internal Bus Cable Connection for IMG1
NAP-200-010
Sheet 30/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the internal bus cables for IMG1 of each LN as shown below. Note that the dotted lines indicate bus
cables for a dual-system.
 MUX MUX
 MUX  MUX
 MUX  MUX
 MUX
 MUX
 ALMB  ALMA
 ALMA
 ALMA
 ALMA
 ALMB
BASEUPIM 0 PIM 1 PIM 2
FA N U PIM 3
PIM 1 TOPU
TOPU FRONT VIEW
REAR VIEW
13 13
1414
BASEU...

Page 163

NDA-24306 CHAPTER 3
Page 135
Revision 1.0
NAP-200-010
Sheet 31/73
Cable Connections
Table 010-8  Internal Bus Cable Connection for IMG1
No.TO FROM
CABLE NAME REMARKS
UNIT/
MODULECONNECTOR 
NAMEUNIT/
MODULECONNECTOR 
NAME
(1) TSWM0 ALM PIM0 ALMA 20AL-(60) FLT CAFor LN0/1 and if LN2/3 
exist.
(2) TSWM0 MUX010 PIM0 MUX (slot 13) 34PH MT24 TSW CA-DFor LN0/1 and if LN2/3 
exist.
(3) TSWM0 MUX110 PIM0 MUX (slot 14) 34PH MT24 TSW CA-D
For dual configuration
For LN0/1 and if LN2/3 
exist.
(4) TSWM0 MUX011 PIM1...

Page 164

CHAPTER 3 NDA-24306
Page 136
Revision 1.0
Figure 010-16  Internal Bus Cable Connection for IMG2
NAP-200-010
Sheet 32/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
MUX000
MUX001 MUX002 MUX003
MUX103(TSW10) (TSW00)
MUX102
MUX101
MUX100
TSWM1PIM0 PIM1 PIM2 PIM3
BASEUTSWM1 PIM0 PIM1 PIM2 PIM3
BASEU TOPUTOPU
FA N UFA N U
ALMA
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(11) (12)
(10)REAR VIEW FRONT VIEW
13 14
13 14
13 14
13 14
Connect the internal bus cables for IMG2 of...

Page 165

NDA-24306 CHAPTER 3
Page 137
Revision 1.0
NAP-200-010
Sheet 33/73
Cable Connections
Table 010-9  Internal Bus Cables for IMG2
No.TO FROM
CABLE NAME REMARKS
UNIT/
MODULECONNECTOR 
NAMEUNIT/
MODULECONNECTOR 
NAME
(1) TSWM1 MUX000 PIM0 MUX (slot 13) 34PH MT24 TSW CA-DWhen IMG2 exists in 
LNn
(2) TSWM1 MUX001 PIM1 MUX (slot 13) 34PH MT24 TSW CA-EWhen PIM1 exists in 
IMG2 of LNn
(3) TSWM1 MUX002 PIM2 MUX (slot 13) 34PH MT24 TSW CA-FWhen PIM2 exists in 
IMG2 of LNn
(4) TSWM1 MUX003 PIM3 MUX (slot 13) 34PH MT24...

Page 166

CHAPTER 3 NDA-24306
Page 138
Revision 1.0
Figure 010-17  Internal Bus Cable Connection for IMG3
NAP-200-010
Sheet 34/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the internal bus cables for IMG3 of all LN as shown below.
Note:For these cable runnings, refer to Section 2: “Inter-frame Cable Connections.”
 MUX  MUX
 MUX  MUX
 MUX
 MUX
 MUX
 MUX
 ALMB  ALMA
 ALMA
 ALMA
 ALMB
 ALMA
 ALMB
BASEU PIM 0 PIM 1 PIM 2
FA N U PIM 3
PIM 1 TO P U
TOPU FRONT VIEW...

Page 167

NDA-24306 CHAPTER 3
Page 139
Revision 1.0
2. INTER-FRAME CABLE CONNECTION FOR LN
This section explains how to run the frame-to-frame cables for LN. Perform this procedure for all the LNs.
NAP-200-010
Sheet 35/73
Cable Connections
START
Confirm connector locations Referring to Figure 010-4,  Figure 010-5 and 010-7, 
confirm the locations of the connectors into which 
the cables are inserted.
Connection of inter-frame bus cables for 
LNReferring to Figure 010-18 through 010-25, 
connect the inter-frame Bus...

Page 168

CHAPTER 3 NDA-24306
Page 140
Revision 1.0
Figure 010-18  Inter-frame ISA Bus Cable Connection for IMG0-IMG1
NAP-200-010
Sheet 36/73
Cable Connections
Table 010-10  Inter-frame ISA Bus Cable Connection for IMG0-IMG1
No.FROM TO
CABLE NAME REMARKS
UNIT/
MODULECONNECTOR 
NAMEUNIT/
MODULECONNECTOR 
NAME
(1)LPM 
(ISAGT0)CN-T TSWM0 IOP0 (slot 11) 34PH 50AL CA-A GT1
(2)LPM 
(ISAGT1)CN-T TSWM0 IOP1 (slot 10) 34PH 50AL CA-A GT0
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the...

Page 169

NDA-24306 CHAPTER 3
Page 141
Revision 1.0
Figure 010-19  Inter-frame Bus Cable Connection for IMG0-IMG1
NAP-200-010
Sheet 37/73
Cable Connections
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Connect the inter-frame bus cables between IMG0 and IMG1 as shown below. Note that the dotted lines indicate
bus cables for a dual-system.
BASEU
BASEUTSWMPIM 0 PIM 1 FA N UPIM 2
FRONT VIEW
REAR VIEWLPM PIM 3 TOPU
13
MUX
14
MUX
1314
1314
1314
TOPU
(4)(6) (5)(8) (7)
(3)
(2)
(1)
IMG 1IMG 0...

Page 170

CHAPTER 3 NDA-24306
Page 142
Revision 1.0
NAP-200-010
Sheet 38/73
Cable Connections
Table 010-11  Inter-frame Bus Cable Connection for IMG0-IMG1
No.TO FROM
CABLE NAME REMARKS
UNIT/
MODULECONNECTOR 
NAMEUNIT/
MODULECONNECTOR 
NAME
(1) TSWM0 MUX000PIM0 
(IMG0)MUX (slot 13) 34PH MT24 TSW CA-F
(2) TSWM0 MUX100PIM0 
(IMG0)MUX (slot 14) 34PH MT24 TSW CA-F
For dual configuration
(3) TSWM0 MUX001PIM1 
(IMG0)MUX (slot 13) 34PH MT24 TSW CA-E
(4) TSWM0 MUX101PIM1 
(IMG0)MUX (slot 14) 34PH MT24 TSW CA-E
For dual...