NDA-24306 CHAPTER 5
Page 313
Revision 1.0
INSTALLATION TEST PROCEDURE
Figure 025-4  LEDs and Switches for PLO Changeover
NAP-200-025
Sheet 8/13
System Changeover Test
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
Legend
Lamp is ON:Lamp is OFF:
 PLO: ST-BY
MB
OPE
 PLO: Active
MB
OPE
green
PH-CK16-A
 PLO: ST-BY
MB
OPE
 PLO: Active
MB
OPE
green
PH-CK16-A / PH-CK17-A
 CLK: ST-BY
MB
OPE
 CLK: Active
MB
OPE
green
PH-CK18
[ISW]
[Local Nodes] 

Page 342

CHAPTER 5 NDA-24306
Page 314
Revision 1.0
INSTALLATION TEST PROCEDURE
Figure 025-5  General Block Diagram of the Whole System (1/2)
NAP-200-025
Sheet 9/13
System Changeover Test
HSW
TSWM0TSWM1
TSWM0TSWM1
This figure roughly shows the general block diagram of the whole system.
MISCIOCEMA
MISCIOCEMA
TSW00TSW01TSW02TSW03
TSW00TSW01TSW02TSW03
FCCS Link
ISWLN0LN1
To PLO of
  LN2/3
GT
ISAGT-A
DLKCPLO
To MUX
(IMG0)To MUX
(IMG1)
To MUX
(IMG0)To MUX
(IMG1)To MUX
(IMG2)To MUX
(IMG3)
To MUX
(IMG2)To MUX
(IMG3)
Note...

Page 343

NDA-24306 CHAPTER 5
Page 315
Revision 1.0
INSTALLATION TEST PROCEDURE
Figure 025-5  General Block Diagram of the Whole System (2/2)
NAP-200-025
Sheet 10/13
System Changeover Test
HSW
TSWM0TSWM1
TSWM0TSWM1
MI S CIOCEMA
MISCIOCEMA
MISCIOCEMA
IOGT
ISAGT
FCCS LinkISWLN0
LN1
To PLO of
  LN1
To MUX(IMG0)To MUX(IMG1)
To MUX
(IMG0)To MUX
(IMG1)To MUX
(IMG2)To MUX
(IMG3)
To MUX
(IMG2)To MUX
(IMG3)
Note 1
Note 3
Note 4
Note 4
Circuit Card 
(No. 0 System) 
Circuit Card 
(No. 1 System)
Note 1HSW00, 01 for No. 0...

Page 344

CHAPTER 5 NDA-24306
Page 316
Revision 1.0
INSTALLATION TEST PROCEDURE
Figure 025-6  System Block Diagram for ISW Switching Network
NAP-200-025
Sheet 11/13
System Changeover Test
This figure shows a system block diagram of ISW, which adopts a dual configuration. As seen in the figure, ISW
has the following terminals for the ACT/ST-BY changeover of dual system equipment:
CPU:If the ACT/ST-BY of CPU (ISW) is once changed over, the whole controlling block (including CPU, IS-
AGT, LANI in ISW) are also...

Page 345

NDA-24306 CHAPTER 5
Page 317
Revision 1.0
INSTALLATION TEST PROCEDURE
Figure 025-7  System Block Diagram for LN Switching Network (1/2)
NAP-200-025
Sheet 12/13
System Changeover Test
This figure shows a system block diagram of LN, which adopts a dual configuration. As seen in the figure, each
LN has following terminals for the ACT/ST-BY changeover of dual system equipment:
CPU:If the ACT/ST-BY of CPU is once changed over, the whole controlling block in the same node (in-
cluding CPU, ISAGT, LANI) and GT...

Page 346

CHAPTER 5 NDA-24306
Page 318
Revision 1.0
INSTALLATION TEST PROCEDURE
Figure 025-7  System Block Diagram for LN Switching Network (2/2)
NAP-200-025
Sheet 13/13
System Changeover Test
ISAGT-A:  PZ-GT13
MUX:  PH-PC36
LANI
GT 0
TSW 00TSW 10TSW 01TSW 11
GT 1
EMA
CLK 0
CLK 1
CPR 0LANICPR 1
MISC BUS
TSW I/O BUS
TSW I/O BUS
Line/Trunk PMIMG 2PCM HW
PCM HW
PCM HW
PCM HW PM BUS PCM HW
PCM HW
PCM HW
PCM HW PM BUS
ISAGT-BISAGT-B
To  T S W M 0
Line/Trunk PMIMG 3
TSWM1
To  T S W M 0
Fr o m  P L O
of ISWM
CPU 0...

Page 347

NDA-24306 CHAPTER 5
Page 319
Revision 1.0
Test Outline
Tests are to be performed to see if the system initialization can be executed on the following basis:
1. System Initialization on a Local Node basis (in each Local Node individually)
2. System Initialization in ISW only
3. System Initialization on a system basis (in ISW and all Local Nodes simultaneously)
NAP-200-026
Sheet 1/5
System Initialization Test
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required 

Page 348

CHAPTER 5 NDA-24306
Page 320
Revision 1.0
1. System Initialization on a Local Node basis
Perform the system initialization test in each Local Node (LN), using the keys on the TOPU (refer to Figure 026-
1):
Figure 026-1  Keys on the TOPU (Local Node)
NAP-200-026
Sheet 2/5
System Initialization Test
START
On the TOPU of the LN to be tested, set the EFFECT key to “ON” side.
On the TOPU, set the SYSTEM DATA key to “NON LOAD” side, and PROGRAM key to “NON LOAD” 
side.
Perform the system initialization by...

Page 349

NDA-24306 CHAPTER 5
Page 321
Revision 1.0
2. System Initialization in ISW
Perform the system initialization test in ISW, by using the keys on the TOPU (refer to Figure 026-2):
Figure 026-2  Keys on the TOPU (ISW)
NAP-200-026
Sheet 3/5
System Initialization Test
START
On the TOPU of ISW, set the INITIAL SELECT key to “SELF” side.
On the TOPU of ISW, set the EFFECT key to “ON” side.
On the TOPU of ISW, set the SYSTEM DATA key to “NON LOAD” side and PROGRAM key to “NON 
LOAD” side.
Perform the system...

Page 350

CHAPTER 5 NDA-24306
Page 322
Revision 1.0
3. System Initialization on a system basis
Perform the system initialization tests in ISW and all Local Nodes simultaneously, per the flowchart cited be-
low. As in the flowchart, there are two kinds of method here; test via the keys on the TOPU of ISW, and test by
turning the power ON and OFF.
NAP-200-026
Sheet 4/5
System Initialization Test
START
Perform the total system initialization via the keys on the TOPU (ISW)
Note:For key allocations, refer to Figure...