CHAPTER 3 NDA-24238
Page 104
Revision 3.0
SYSTEM MESSAGES
➄ Called Party Information
Station to Station Call
OG Call to outside (IC Call from outside)
b4-b7 b0-b3
(a)
Te n a n t  N o .
Te n a n t  N o .
DC0 DC1
DC2 DC3
DC4 DC5(a) Type of called party
00 = Station
01 = Attendant Console
b7 b6 b5 b4 b3 b2 b1 b0
b0-b7
Route No. (Hex)
Route No. (Hex)
Trunk No. (Hex)
Trunk No. (Hex)b4-b7 b0-b3
Route No. (Hex)
Route No. (Hex)
Trunk No. (Hex)
Trunk No. (Hex)
DC0 DC1
DC2 DC3
DC4 DC5
DC6 DC7
DC8 DC9
DC10 DC11...

Page 132

NDA-24238 CHAPTER 3
Page 105
Revision 3.0
SYSTEM MESSAGES
This message displays when the SMDR output buffer usage rate has exceeded the value assigned to ASYD,
SYS1, Index 249.
➀ Detail Information
(a) FS = 0, FE = 0/1
➁
1: XXXX XXXX 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂ ➃
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
b7 b0
Default Alarm:
SUP6-OSMDR Output Buffer...

Page 133

CHAPTER 3 NDA-24238
Page 106
Revision 3.0
SYSTEM MESSAGES
➂ Buffer Usage Rate Assigned by 
ASYD, SYS1, Index 249
➃ Buffer Usage Rate Assigned by 
ASYD, SYS1, Index 250
(b) FS = 1, FE = 0
➁
➂ 
Overflow Rate
➃ Overflow Rate b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b2 b1 b0
b7 b0
b7 b6 b5 b4 b0
b0-b3: Units
b4-b7: Tens
b0-b3: Units
b4-b7: Tens
b0: Fault Grade by ALMG command
00 = NON CONT 01 = SUP
10 = MN 11 = MJ
b0: 0/1 = -/100% Overflow
b4-b7: 1-9 = 10%-90% Overflow 

Page 134

NDA-24238 CHAPTER 3
Page 107
Revision 3.0
SYSTEM MESSAGES
(c) FS = 2, FE = 0
➁ SMDR Group No.
➂ Port No.
➃ Not used
(d) FS = 3, FE = 0
➁
b7 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b3 b2 b1 b0
b0-b3: SMDR Group No. to which failure occurred
b0-b7: Port No. allocated for SMDR Group to which failure occurred (0-7)
b0-b3: SMDR Group No. to which failure occurred 

Page 135

CHAPTER 3 NDA-24238
Page 108
Revision 3.0
SYSTEM MESSAGES
This message displays when the SMDR output buffer usage rate has been lowered to less than the value as-
signed in the ASYD, SYS1, Index 250 after the rate exceeds the value assigned by Index 249.
➀ Detail Information
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1...

Page 136

NDA-24238 CHAPTER 3
Page 109
Revision 3.0
SYSTEM MESSAGES
This message displays after the office data is loaded and system initialization has executed.
➀ 
➁ 
Load Status
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b15 b11 b9 b8
Default Alarm:
NON7-ASystem Initialize With Data LoadDefault Grade:...

Page 137

CHAPTER 3 NDA-24238
Page 110
Revision 3.0
SYSTEM MESSAGES
Note 1:
Phase1 Restart is executed when initializing the system without disrupting the following two-way con-
nections that have already been established:
 Basic two-way connections (STN-STN, STN-TRK, TRK-TRK)
 Fixed connections
 Two-way connections established on a Fusion link
For more details, see Section Chapter 6, Section 12.2.3.
Note 2:Number Sharing data load also affects the data load of Dual Station Calling Over-FCCS. 

Page 138

NDA-24238 CHAPTER 3
Page 111
Revision 3.0
SYSTEM MESSAGES
This message displays when system initialization is activated.
➀
Note:Phase1 Restart is executed when initializing the system without disrupting the following two-way
connections that have already been established:
 Basic two-way connections (STN-STN, STN-TRK, TRK-TRK)
 Fixed connections
 Two-way connections established on a Fusion link
For more details, see Chapter 6, Section 12.2.3.
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000...

Page 139

CHAPTER 3 NDA-24238
Page 112
Revision 3.0
SYSTEM MESSAGES
This message displays when the MBR switch on the GATE card is turned ON at the time of CPU changeover
or speech path changeover.
➀ Self-CPU Restart information
➁ Mate-CPU Restart information
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b5 b4 b3 b0
b7 b5 b4 b3 b0
Default Alarm:...

Page 140

NDA-24238 CHAPTER 3
Page 113
Revision 3.0
SYSTEM MESSAGES
This message displays when the MBR switch on the GATE card is turned OFF at the time of CPU changeover
or speech path changeover.
➀ Self-CPU Restart information
➁ Mate-CPU Restart information
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b5 b4 b3 b0
b7 b5 b4 b3 b0
Default Alarm:...