CHAPTER 3 NDA-24238 Page 104 Revision 3.0 SYSTEM MESSAGES ➄ Called Party Information Station to Station Call OG Call to outside (IC Call from outside) b4-b7 b0-b3 (a) Te n a n t N o . Te n a n t N o . DC0 DC1 DC2 DC3 DC4 DC5(a) Type of called party 00 = Station 01 = Attendant Console b7 b6 b5 b4 b3 b2 b1 b0 b0-b7 Route No. (Hex) Route No. (Hex) Trunk No. (Hex) Trunk No. (Hex)b4-b7 b0-b3 Route No. (Hex) Route No. (Hex) Trunk No. (Hex) Trunk No. (Hex) DC0 DC1 DC2 DC3 DC4 DC5 DC6 DC7 DC8 DC9 DC10 DC11...
Page 132
NDA-24238 CHAPTER 3 Page 105 Revision 3.0 SYSTEM MESSAGES This message displays when the SMDR output buffer usage rate has exceeded the value assigned to ASYD, SYS1, Index 249. ➀ Detail Information (a) FS = 0, FE = 0/1 ➁ 1: XXXX XXXX 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b0 Default Alarm: SUP6-OSMDR Output Buffer...
Page 133
CHAPTER 3 NDA-24238 Page 106 Revision 3.0 SYSTEM MESSAGES ➂ Buffer Usage Rate Assigned by ASYD, SYS1, Index 249 ➃ Buffer Usage Rate Assigned by ASYD, SYS1, Index 250 (b) FS = 1, FE = 0 ➁ ➂ Overflow Rate ➃ Overflow Rate b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b2 b1 b0 b7 b0 b7 b6 b5 b4 b0 b0-b3: Units b4-b7: Tens b0-b3: Units b4-b7: Tens b0: Fault Grade by ALMG command 00 = NON CONT 01 = SUP 10 = MN 11 = MJ b0: 0/1 = -/100% Overflow b4-b7: 1-9 = 10%-90% Overflow
Page 134
NDA-24238 CHAPTER 3 Page 107 Revision 3.0 SYSTEM MESSAGES (c) FS = 2, FE = 0 ➁ SMDR Group No. ➂ Port No. ➃ Not used (d) FS = 3, FE = 0 ➁ b7 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b3 b2 b1 b0 b0-b3: SMDR Group No. to which failure occurred b0-b7: Port No. allocated for SMDR Group to which failure occurred (0-7) b0-b3: SMDR Group No. to which failure occurred
Page 135
CHAPTER 3 NDA-24238 Page 108 Revision 3.0 SYSTEM MESSAGES This message displays when the SMDR output buffer usage rate has been lowered to less than the value as- signed in the ASYD, SYS1, Index 250 after the rate exceeds the value assigned by Index 249. ➀ Detail Information 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1...
Page 136
NDA-24238 CHAPTER 3 Page 109 Revision 3.0 SYSTEM MESSAGES This message displays after the office data is loaded and system initialization has executed. ➀ ➁ Load Status 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b15 b11 b9 b8 Default Alarm: NON7-ASystem Initialize With Data LoadDefault Grade:...
Page 137
CHAPTER 3 NDA-24238 Page 110 Revision 3.0 SYSTEM MESSAGES Note 1: Phase1 Restart is executed when initializing the system without disrupting the following two-way con- nections that have already been established: Basic two-way connections (STN-STN, STN-TRK, TRK-TRK) Fixed connections Two-way connections established on a Fusion link For more details, see Section Chapter 6, Section 12.2.3. Note 2:Number Sharing data load also affects the data load of Dual Station Calling Over-FCCS.
Page 138
NDA-24238 CHAPTER 3 Page 111 Revision 3.0 SYSTEM MESSAGES This message displays when system initialization is activated. ➀ Note:Phase1 Restart is executed when initializing the system without disrupting the following two-way connections that have already been established: Basic two-way connections (STN-STN, STN-TRK, TRK-TRK) Fixed connections Two-way connections established on a Fusion link For more details, see Chapter 6, Section 12.2.3. 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000...
Page 139
CHAPTER 3 NDA-24238 Page 112 Revision 3.0 SYSTEM MESSAGES This message displays when the MBR switch on the GATE card is turned ON at the time of CPU changeover or speech path changeover. ➀ Self-CPU Restart information ➁ Mate-CPU Restart information 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 Default Alarm:...
Page 140
NDA-24238 CHAPTER 3 Page 113 Revision 3.0 SYSTEM MESSAGES This message displays when the MBR switch on the GATE card is turned OFF at the time of CPU changeover or speech path changeover. ➀ Self-CPU Restart information ➁ Mate-CPU Restart information 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 Default Alarm:...