Page 171

CHAPTER 3 NDA-24238
Page 144
Revision 3.0
SYSTEM MESSAGES
➆-➉ MUX card (STBY) linkage 
condition
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
➆Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
0: -
1: MUX connection error 
(functional fault/not 
mounted) MG1
MG0
➇Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
MG3
MG2
➈Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
MG5
MG4
➉Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
MG7
MG6
As shown in the...

Page 172

NDA-24238 CHAPTER 3
Page 145
Revision 3.0
SYSTEM MESSAGES
[41H] CPU ACT/STBY Changeover Failure
➀ Error detection by Routine 
Diagnosis
➁ ACT system after changeover
1: 41XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b1 b0
[41H] CPU ACT/STBY Changeover Failure
b0: CPU
0/1 = #0 is ACT/#1 is ACT
b1: TSW
0/1 = #0 is ACT/#1 is ACT 

Page 173

CHAPTER 3 NDA-24238
Page 146
Revision 3.0
SYSTEM MESSAGES
[42H] CPU ACT/STBY Changeover Failure (DM Verification NG or PM Verification NG)
➀ Error detection by Routine 
Diagnosis
➁ ACT system after changeover
1: 42XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b1 b0
[42H] CPU ACT/STBY Changeover Failure
(DM Verification NG)
b0: CPU
0/1 = #0 is...

Page 174

NDA-24238 CHAPTER 3
Page 147
Revision 3.0
SYSTEM MESSAGES
[43H] CPU ACT/STBY Changeover Failure (PCI Fault)
➀ Error detection by Routine 
Diagnosis
➁ ACT system after changeover
1: 43XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b1 b0
[43H] CPU ACT/STBY Changeover Failure (PCI Fault)
b0: CPU
0/1 = #0 is ACT/#1 is ACT
b1: TSW
0/1 = #0 is ACT/#1...

Page 175

CHAPTER 3 NDA-24238
Page 148
Revision 3.0
SYSTEM MESSAGES
[44H] CPU ACT/STBY Changeover Failure (Changeover NG or CPU RAM Copy NG)
➀ Error detection by Routine 
Diagnosis
➁ ACT system after changeover
1: 44XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b1 b0
[44H] CPU ACT/STBY Changeover Failure
Changeover NG or CPU RAM Copy NG)
b0: CPU
0/1 = #0...

Page 176

NDA-24238 CHAPTER 3
Page 149
Revision 3.0
SYSTEM MESSAGES
[50H] Trunk Ineffective Hold Detected 
➀ Error detection by Routine 
Diagnosis
➁ LENS of Trunk Ineffective Hold 
(MG, U)
➂ LENS of Ineffective Hold Trunk (G, LV)
1: 50XX 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
➀ ➁ ➂ ➂
4: XXXX XXXX XXXX XXXX 5: XXXX XX00 0000 0000 6: 0000 0000 0000 0000
➂➂
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b2 b1 b0
Group No.
1: 500X 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3:...

Page 177

CHAPTER 3 NDA-24238
Page 150
Revision 3.0
SYSTEM MESSAGES
[51H] Trunk Ineffective Hold Detected and Released 
➀ Error detection by Routine 
Diagnosis
➁ LENS of Trunk Ineffective Hold 
Detected and Released (MG, U)
➂ LENS of Ineffective Hold Trunk (G, LV)
1: 50XX 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
➀ ➁ ➂ ➂ ➂
4: XXXX XXXX XXXX XXXX 5: XXXX XX00 0000 0000 6: 0000 0000 0000 0000
➂➃
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b2 b1 b0
Group No.
1: 500X 00XX...

Page 178

NDA-24238 CHAPTER 3
Page 151
Revision 3.0
SYSTEM MESSAGES
[52H] Trunk Ineffective Hold Detected Impossible 
➀ Error detection by Routine 
Diagnosis
➁ Cause for suspended detection of 
Trunk Ineffective Hold
1: XX00 XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀  ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b1 b0
[52H] Trunk Ineffective Hold Detected Impossible
b1
b0
0 1 = CPU to detect is...

Page 179

CHAPTER 3 NDA-24238
Page 152
Revision 3.0
SYSTEM MESSAGES
[70H] Call Forwarding Memory Clear NG 
➀ Error detection by Routine 
Diagnosis
➁ Cause for which Transfer Memory 
was stopped
1: 7000 XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀  ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b1 b0
[70H] Call Forwarding Memory Clear NG
b1
b0
0 1 = CPU is abnormal
1 0 = Data Transfer error 

Page 180

NDA-24238 CHAPTER 3
Page 153
Revision 3.0
SYSTEM MESSAGES
[A0H] Periodic Backup Abnormal End
➀ Error detection by Routine 
Diagnosis
➁ Information of Periodic Backup 
Abnormal End
➂ Backup Data to No. 0 system
➃ Error Code of No. 0 system HD
Note:Number Sharing data load also affects the data load of Dual Station Calling Over-FCCS.
1: A0XX XX00 XXXX XX00 2: XXXX XXXX XXXX XX00 3: 0000 0000 0000 0000
➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉
4: 0000 0000 0000 0000 5: 0000 0000 0000 00006: 0000 0000 0000 0000
7: 0000 0000 0000...