Page 171
CHAPTER 3 NDA-24238 Page 144 Revision 3.0 SYSTEM MESSAGES ➆-➉ MUX card (STBY) linkage condition b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 ➆Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 0: - 1: MUX connection error (functional fault/not mounted) MG1 MG0 ➇Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 MG3 MG2 ➈Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 MG5 MG4 ➉Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 MG7 MG6 As shown in the...
Page 172
NDA-24238 CHAPTER 3 Page 145 Revision 3.0 SYSTEM MESSAGES [41H] CPU ACT/STBY Changeover Failure ➀ Error detection by Routine Diagnosis ➁ ACT system after changeover 1: 41XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b1 b0 [41H] CPU ACT/STBY Changeover Failure b0: CPU 0/1 = #0 is ACT/#1 is ACT b1: TSW 0/1 = #0 is ACT/#1 is ACT
Page 173
CHAPTER 3 NDA-24238 Page 146 Revision 3.0 SYSTEM MESSAGES [42H] CPU ACT/STBY Changeover Failure (DM Verification NG or PM Verification NG) ➀ Error detection by Routine Diagnosis ➁ ACT system after changeover 1: 42XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b1 b0 [42H] CPU ACT/STBY Changeover Failure (DM Verification NG) b0: CPU 0/1 = #0 is...
Page 174
NDA-24238 CHAPTER 3 Page 147 Revision 3.0 SYSTEM MESSAGES [43H] CPU ACT/STBY Changeover Failure (PCI Fault) ➀ Error detection by Routine Diagnosis ➁ ACT system after changeover 1: 43XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b1 b0 [43H] CPU ACT/STBY Changeover Failure (PCI Fault) b0: CPU 0/1 = #0 is ACT/#1 is ACT b1: TSW 0/1 = #0 is ACT/#1...
Page 175
CHAPTER 3 NDA-24238 Page 148 Revision 3.0 SYSTEM MESSAGES [44H] CPU ACT/STBY Changeover Failure (Changeover NG or CPU RAM Copy NG) ➀ Error detection by Routine Diagnosis ➁ ACT system after changeover 1: 44XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b1 b0 [44H] CPU ACT/STBY Changeover Failure Changeover NG or CPU RAM Copy NG) b0: CPU 0/1 = #0...
Page 176
NDA-24238 CHAPTER 3 Page 149 Revision 3.0 SYSTEM MESSAGES [50H] Trunk Ineffective Hold Detected ➀ Error detection by Routine Diagnosis ➁ LENS of Trunk Ineffective Hold (MG, U) ➂ LENS of Ineffective Hold Trunk (G, LV) 1: 50XX 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX ➀ ➁ ➂ ➂ 4: XXXX XXXX XXXX XXXX 5: XXXX XX00 0000 0000 6: 0000 0000 0000 0000 ➂➂ 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b2 b1 b0 Group No. 1: 500X 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3:...
Page 177
CHAPTER 3 NDA-24238 Page 150 Revision 3.0 SYSTEM MESSAGES [51H] Trunk Ineffective Hold Detected and Released ➀ Error detection by Routine Diagnosis ➁ LENS of Trunk Ineffective Hold Detected and Released (MG, U) ➂ LENS of Ineffective Hold Trunk (G, LV) 1: 50XX 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX ➀ ➁ ➂ ➂ ➂ 4: XXXX XXXX XXXX XXXX 5: XXXX XX00 0000 0000 6: 0000 0000 0000 0000 ➂➃ 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b2 b1 b0 Group No. 1: 500X 00XX...
Page 178
NDA-24238 CHAPTER 3 Page 151 Revision 3.0 SYSTEM MESSAGES [52H] Trunk Ineffective Hold Detected Impossible ➀ Error detection by Routine Diagnosis ➁ Cause for suspended detection of Trunk Ineffective Hold 1: XX00 XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b1 b0 [52H] Trunk Ineffective Hold Detected Impossible b1 b0 0 1 = CPU to detect is...
Page 179
CHAPTER 3 NDA-24238 Page 152 Revision 3.0 SYSTEM MESSAGES [70H] Call Forwarding Memory Clear NG ➀ Error detection by Routine Diagnosis ➁ Cause for which Transfer Memory was stopped 1: 7000 XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b1 b0 [70H] Call Forwarding Memory Clear NG b1 b0 0 1 = CPU is abnormal 1 0 = Data Transfer error
Page 180
NDA-24238 CHAPTER 3 Page 153 Revision 3.0 SYSTEM MESSAGES [A0H] Periodic Backup Abnormal End ➀ Error detection by Routine Diagnosis ➁ Information of Periodic Backup Abnormal End ➂ Backup Data to No. 0 system ➃ Error Code of No. 0 system HD Note:Number Sharing data load also affects the data load of Dual Station Calling Over-FCCS. 1: A0XX XX00 XXXX XX00 2: XXXX XXXX XXXX XX00 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉ 4: 0000 0000 0000 0000 5: 0000 0000 0000 00006: 0000 0000 0000 0000 7: 0000 0000 0000...