NEC Neax 2400 Imx System Operations And Maintenance Manual

Here you can view all the pages of manual NEC Neax 2400 Imx System Operations And Maintenance Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 191

CHAPTER 3 NDA-24238
Page 164
Revision 3.0
SYSTEM MESSAGES
This message displays when B-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit
card has occurred
.
➀ Location of faulty CCH/DCH card
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
Default Alarm:
SUP13-GCCH B-Level Infinite Loop Failure...

Page 192

NDA-24238 CHAPTER 3
Page 165
Revision 3.0
SYSTEM MESSAGES
This message displays when a failure has occurred numerous times to a common channel signaling link and
the link has been placed into make-busy state
.
➀ Location of faulty CCH/DCH card
➁ Data Analyzed by NEC Engineers
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2...

Page 193

CHAPTER 3 NDA-24238
Page 166
Revision 3.0
SYSTEM MESSAGES
➂ Probable cause for failure
b7 b3 b2 b1 b0b0-b3: See Table.
FLT IDCCITT 
ERROR FA C TO R
00 A S (F = 1) frame is received.
01 B DM (F = 1) response is received.
02 C UA (F = 1) response is received.
03 D UA (F = 0) response is received.
04 E DM (F = 0) response is received.
05 F SABME command is received.
06 G N200 Timeout (Link is set)
07 H N200 Timeout (Link is disconnected)
08 I N200 Timeout (Link failure is restored 
to normal)
09 J N (R)...

Page 194

NDA-24238 CHAPTER 3
Page 167
Revision 3.0
SYSTEM MESSAGES
This message displays when a failure has occurred numerous times to a common channel signaling link and
the link has been placed into make-busy state. When this fault lasts over three minutes, the system message
changes to [13-H] CCS Link Failure (Permanent)
.
➀ Location of faulty CCH/DCH card
➁ Data Analyzed by NEC Engineers
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6:...

Page 195

CHAPTER 3 NDA-24238
Page 168
Revision 3.0
SYSTEM MESSAGES
➂ Probable cause for the failure
b7 b3 b2 b1 b0b0-b3: See Table.
FLT IDCCITT 
ERROR FAC TO R
00 A S (F = 1) frame is received.
01 B DM (F = 1) response is received.
02 C UA (F = 1) response is received.
03 D UA (F = 0) response is received.
04 E DM (F = 0) response is received.
05 F SABME command is received.
06 G N200 Timeout (Link is set)
07 H N200 Timeout (Link is disconnected)
08 I N200 Timeout (Link failure is restored 
to normal)
09 J N (R)...

Page 196

NDA-24238 CHAPTER 3
Page 169
Revision 3.0
SYSTEM MESSAGES
This message displays when the faults pertaining to CCIS/ISDN Link are restored to normal.
➀ Location of faulty CCH/DCH card
➁ CKT No. of faulty circuit
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
Default Alarm:
NON13-JRestoration From...

Page 197

CHAPTER 3 NDA-24238
Page 170
Revision 3.0
SYSTEM MESSAGES
This message displays when a fault occurred to the Port Microprocessor (PM) within the CCH/DCH circuit
card and the restart processing is executed
.
➀ Location of faulty CCH/DCH card
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
Default Alarm:
SUP13-KCCH Reset...

Page 198

NDA-24238 CHAPTER 3
Page 171
Revision 3.0
SYSTEM MESSAGES
This message displays when a digital line failure occurs.
➀ Accommodated location
➁ Kind of Fault
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
b7 b4 b3 b2 b1 b0
Default Alarm:
SUP13-NDigital Line WarningDefault Grade:
1Grade Modified: Lamp Modified:
b0-b4:...

Page 199

CHAPTER 3 NDA-24238
Page 172
Revision 3.0
SYSTEM MESSAGES
This message displays when a digital line failure occurs.
➀ Accommodated location
➁ Kind of Fault
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
b7 b4 b3 b2 b1 b0
Default Alarm:
SUP13-ODigital Line FailureDefault Grade:
2Grade Modified: Lamp Modified:
b0-b4:...

Page 200

NDA-24238 CHAPTER 3
Page 173
Revision 3.0
SYSTEM MESSAGES
This message displays when a digital line failure is restored to normal.
➀ Accommodated location
➁ Kind of Fault
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
b7 b4 b3 b2 b1 b0
Default Alarm:
NON13-PDigital Line RestoreDefault Grade:
0Grade Modified: Lamp...