Page 191
CHAPTER 3 NDA-24238 Page 164 Revision 3.0 SYSTEM MESSAGES This message displays when B-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit card has occurred . ➀ Location of faulty CCH/DCH card 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP13-GCCH B-Level Infinite Loop Failure...
Page 192
NDA-24238 CHAPTER 3 Page 165 Revision 3.0 SYSTEM MESSAGES This message displays when a failure has occurred numerous times to a common channel signaling link and the link has been placed into make-busy state . ➀ Location of faulty CCH/DCH card ➁ Data Analyzed by NEC Engineers 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2...
Page 193
CHAPTER 3 NDA-24238 Page 166 Revision 3.0 SYSTEM MESSAGES ➂ Probable cause for failure b7 b3 b2 b1 b0b0-b3: See Table. FLT IDCCITT ERROR FA C TO R 00 A S (F = 1) frame is received. 01 B DM (F = 1) response is received. 02 C UA (F = 1) response is received. 03 D UA (F = 0) response is received. 04 E DM (F = 0) response is received. 05 F SABME command is received. 06 G N200 Timeout (Link is set) 07 H N200 Timeout (Link is disconnected) 08 I N200 Timeout (Link failure is restored to normal) 09 J N (R)...
Page 194
NDA-24238 CHAPTER 3 Page 167 Revision 3.0 SYSTEM MESSAGES This message displays when a failure has occurred numerous times to a common channel signaling link and the link has been placed into make-busy state. When this fault lasts over three minutes, the system message changes to [13-H] CCS Link Failure (Permanent) . ➀ Location of faulty CCH/DCH card ➁ Data Analyzed by NEC Engineers 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6:...
Page 195
CHAPTER 3 NDA-24238 Page 168 Revision 3.0 SYSTEM MESSAGES ➂ Probable cause for the failure b7 b3 b2 b1 b0b0-b3: See Table. FLT IDCCITT ERROR FAC TO R 00 A S (F = 1) frame is received. 01 B DM (F = 1) response is received. 02 C UA (F = 1) response is received. 03 D UA (F = 0) response is received. 04 E DM (F = 0) response is received. 05 F SABME command is received. 06 G N200 Timeout (Link is set) 07 H N200 Timeout (Link is disconnected) 08 I N200 Timeout (Link failure is restored to normal) 09 J N (R)...
Page 196
NDA-24238 CHAPTER 3 Page 169 Revision 3.0 SYSTEM MESSAGES This message displays when the faults pertaining to CCIS/ISDN Link are restored to normal. ➀ Location of faulty CCH/DCH card ➁ CKT No. of faulty circuit 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON13-JRestoration From...
Page 197
CHAPTER 3 NDA-24238 Page 170 Revision 3.0 SYSTEM MESSAGES This message displays when a fault occurred to the Port Microprocessor (PM) within the CCH/DCH circuit card and the restart processing is executed . ➀ Location of faulty CCH/DCH card 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP13-KCCH Reset...
Page 198
NDA-24238 CHAPTER 3 Page 171 Revision 3.0 SYSTEM MESSAGES This message displays when a digital line failure occurs. ➀ Accommodated location ➁ Kind of Fault 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b4 b3 b2 b1 b0 Default Alarm: SUP13-NDigital Line WarningDefault Grade: 1Grade Modified: Lamp Modified: b0-b4:...
Page 199
CHAPTER 3 NDA-24238 Page 172 Revision 3.0 SYSTEM MESSAGES This message displays when a digital line failure occurs. ➀ Accommodated location ➁ Kind of Fault 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b4 b3 b2 b1 b0 Default Alarm: SUP13-ODigital Line FailureDefault Grade: 2Grade Modified: Lamp Modified: b0-b4:...
Page 200
NDA-24238 CHAPTER 3 Page 173 Revision 3.0 SYSTEM MESSAGES This message displays when a digital line failure is restored to normal. ➀ Accommodated location ➁ Kind of Fault 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b4 b3 b2 b1 b0 Default Alarm: NON13-PDigital Line RestoreDefault Grade: 0Grade Modified: Lamp...