Page 201
CHAPTER 3 NDA-24238 Page 174 Revision 3.0 SYSTEM MESSAGES This message displays when the battery is operated in the DRU system. ➀ Accommodated location 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP13-QDRU Battery OperationDefault Grade: 1Grade Modified: Lamp Modified: b0-b4: Group No. b5, b6: Unit No....
Page 202
NDA-24238 CHAPTER 3 Page 175 Revision 3.0 SYSTEM MESSAGES This message displays when the main power of the DRU system is restored to normal. ➀ Accommodated location 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON13-RDRU Line OperationDefault Grade: 0Grade Modified: Lamp Modified: b0-b4: Group No. b5,...
Page 203
CHAPTER 3 NDA-24238 Page 176 Revision 3.0 SYSTEM MESSAGES This message displays when a PWR circuit card failure is detected. ➀ MG No. and Unit No. of fault detection ➁ Kind of Power ➂ Location of faulty circuit card Reference: See Chapter 4, Section 3.3.3, for the circuit card replacement procedure. 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000...
Page 204
NDA-24238 CHAPTER 3 Page 177 Revision 3.0 SYSTEM MESSAGES This message displays when a VPS failure is detected. ➀ Probable cause for failure ➁ LENS of VPS with the failure ➂ LENS of VPS with the failure 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm:...
Page 205
CHAPTER 3 NDA-24238 Page 178 Revision 3.0 SYSTEM MESSAGES This message displays when a VPS failure is detected. ➀ Probable cause for failure ➁ LENS of VPS with the failure ➂ LENS of VPS with the failure 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm:...
Page 206
NDA-24238 CHAPTER 3 Page 179 Revision 3.0 SYSTEM MESSAGES This message displays when a VPS failure is restored to normal. ➀ LENS of VPS with the failure ➁ LENS of VPS with the failure 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON15-CVPS RestoreDefault Grade: 2Grade Modified:...
Page 207
CHAPTER 3 NDA-24238 Page 180 Revision 3.0 SYSTEM MESSAGES This message displays when Intra-Office Trunks (ATI, RST, etc.) have all become busy. ➀ Intra-Office trunks that have become all busy 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP16-AInside Trunk All BusyDefault Grade: 3Grade Modified: Lamp...
Page 208
NDA-24238 CHAPTER 3 Page 181 Revision 3.0 SYSTEM MESSAGES ROUTE NO.DATA (HEX.)TRUNK NAMEROUTE NO.DATA (HEX.)TRUNK NAME 901 01 Attendant Console 917 11 MFC Sender 902 02 Originating Register Trunk 918 12 Not used 903 03 Incoming Register Trunk 919 13 MODEM 904 04 MF Receiver 920 14 MODEM 905 05 Sender Trunk DP/PB 921 15 MODEM 906 06 PB Receiver for Automated Attendant Service922 16 MODEM 907 07 AMP 923 17 MODEM 908 08 Not used 924 18 MODEM 909 09 Three-Way Conference Trunk 925 19 MODEM 910 0A Not...
Page 209
CHAPTER 3 NDA-24238 Page 182 Revision 3.0 SYSTEM MESSAGES This message displays when virtual tie line setup has completed. ➀ Counter ➁ Virtual Tie Line Call Header Accommodated Location ➂ Virtual Tie Line Call Header Accommodated Location 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b0 b7 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 Default...
Page 210
NDA-24238 CHAPTER 3 Page 183 Revision 3.0 SYSTEM MESSAGES This message displays when virtual tie line cancel has completed. ➀ Counter ➁ Virtual Tie Line Call Header Accommodated Location ➂ Virtual Tie Line Call Header Accommodated Location 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b0 b7 b2 b1 b0 b7 b2 b1 b0 Default Alarm:...