Page 251

CHAPTER 3 NDA-24238
Page 224
Revision 3.0
SYSTEM MESSAGES
This message is issued when the connection error related to external LAN Interface equipment occurs in the
system.
➀~➃ IP Address for external equipment in which error has been detected. (Hex.)
➄, ➅ Port No. (Client Port No.) (Hex.)
➆ Socket No. (Used Socket No.) (Hex.)
➇ Error Code (TCP/IP Error Code) (Hex.) See Ta b l e  3 - 2. TCP/IP Part Application Part
1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉...

Page 252

NDA-24238 CHAPTER 3
Page 225
Revision 3.0
SYSTEM MESSAGES
Table 3-2  Error Code
Output Data 
(Hex.)DefinitionOutput Data 
(Hex.)Definition
BSD SOCKET ERROR 58 Address family not supported
10 User parameter error PROTOCOL FAMILY
11 Host not reachable 59 Address already in use
12 Timeout 60 Can’t assign requested address
14 Protocol error 61 Network is down
15 No buffer space *//62 Network is unreachable
16 Connection block invalid 63 Network dropped connection
17 Invalid pointer argument RESET
18...

Page 253

CHAPTER 3 NDA-24238
Page 226
Revision 3.0
SYSTEM MESSAGES
➈ Application Type
[When  =03 (SMDR) / 04 (MCI) ]
➉ Device Number of Error detected client PC
 Kind of Error
 Details on Detected Error 
~ Not used
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b0-b7 : (Hex)
01=SUPER SERVER
02=MAT
03=SMDR
04=MCI
05=OAI
06=PMS
07=MIS
9
b0-b7: (Hex)
Device Number of error detected Client PC. 
If the Machine Number is not determined, “FF”
is output.
b0-b7: (Hex)...

Page 254

NDA-24238 CHAPTER 3
Page 227
Revision 3.0
SYSTEM MESSAGES
[When =05 (OAI) / 07 (MIS) ]
➉ Faulty Logical Port No. (Hex)
 Error Kind (ERRK)
~ Not used b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
Table 3-3  Error Kind (ERRK)
Output Data Error Situation Required Check
01H SEND Execution Error
TCP/IP connection is down because the text is not transmit-
ted continuously.[1] Check the TCP/IP Transmission 
capacity on the UAP side is proper 
or not.
[2] Check the operation status on the UAP 
side is normal....

Page 255

CHAPTER 3 NDA-24238
Page 228
Revision 3.0
SYSTEM MESSAGES
This message displays when the LAN Interface Connection Failure, detected in Message [26-V], recovers. The
message displays when the LAN Interface Connection Failure is restored. The first data is normally sent/re-
ceived by the recovered application equipment.
➀-➃ IP Address for external equipment in which error has been detected. (Hex.)
➄, ➅ Port No. (Client Port No.) (Hex.)
➆ Socket No. (Used Socket No.) (Hex.)
➇ Error Code (TCP/IP Error Code)...

Page 256

NDA-24238 CHAPTER 3
Page 229
Revision 3.0
SYSTEM MESSAGES
➈ Application Type
 
[When ➈
➈➈ ➈=03 (SMDR) / 04 (MCI) ]
➉ Device Number of recovered client PC
 Recovery Information
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b0-b7: (Hex)
01=SUPER SERVER
02=MAT
03=SMDR
04=MCI
05=OAI
06=PMS
07=MIS
b0-b7: (Hex)
Device Number of recovered Client PC 
for external LAN Interface.
b0-b7: (Hex)
01=Recovered
02~FF=Not defined
11 

Page 257

CHAPTER 3 NDA-24238
Page 230
Revision 3.0
SYSTEM MESSAGES
This message displays when the MUX (PH-PC36) card, whose clock function was detected as faulty, is recov-
ered.
➀ Unit, MG number for MUX card, 
which recovered from a clock 
failure
➁ RLS Data
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b4 b3 b2 b1 b0
b7 b3 b2 b1 b0
Default...

Page 258

NDA-24238 CHAPTER 3
Page 231
Revision 3.0
SYSTEM MESSAGES
This message displays when an abnormal state is detected temporarily on the SDT (PA-SDTA/B) card.
➀ MG (Module Group)
➁ Details on alarm
Note:Alarm-detected HW is specified in ➂ (next page).
1: X0XX 00XX XXXX XX00 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b0
b7 b4 b3 b2 b1 b0
Default Alarm:...

Page 259

CHAPTER 3 NDA-24238
Page 232
Revision 3.0
SYSTEM MESSAGES
➂ Alarm-detected HW
Note:This data displays only when b4 is “1” and b3 is “0” in data ➁.
Repair Procedure
Basically, fault repair work is not required by the display of this message. However, if the message is created
frequently, it is recommended that the repair work be performed as shown in the message [33-C] SDT Alarm
Trouble. b7 b6 b5 b4 b3 b2 b1 b0
The data here specifies the HW, on which any of the VC-11 Path 
Trouble was detected in data 
➁...

Page 260

NDA-24238 CHAPTER 3
Page 233
Revision 3.0
SYSTEM MESSAGES
This message displays when a grave failure occurs on the SDT (PA-SDTA/B) card. If this is issued, remember
the ACT/STBY change of the SDT card may be followed, as a result of fault detection in the optical fiber line
(see [33-E] message).
➀ MG (Module Group)
➁ Details on alarm
Note:Fault repair procedure on each alarm is shown on the next page.
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000...