CHAPTER 3 NDA-24238 Page 224 Revision 3.0 SYSTEM MESSAGES This message is issued when the connection error related to external LAN Interface equipment occurs in the system. ➀~➃ IP Address for external equipment in which error has been detected. (Hex.) ➄, ➅ Port No. (Client Port No.) (Hex.) ➆ Socket No. (Used Socket No.) (Hex.) ➇ Error Code (TCP/IP Error Code) (Hex.) See Ta b l e 3 - 2. TCP/IP Part Application Part 1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉...
Page 252
NDA-24238 CHAPTER 3 Page 225 Revision 3.0 SYSTEM MESSAGES Table 3-2 Error Code Output Data (Hex.)DefinitionOutput Data (Hex.)Definition BSD SOCKET ERROR 58 Address family not supported 10 User parameter error PROTOCOL FAMILY 11 Host not reachable 59 Address already in use 12 Timeout 60 Can’t assign requested address 14 Protocol error 61 Network is down 15 No buffer space *//62 Network is unreachable 16 Connection block invalid 63 Network dropped connection 17 Invalid pointer argument RESET 18...
Page 253
CHAPTER 3 NDA-24238 Page 226 Revision 3.0 SYSTEM MESSAGES ➈ Application Type [When =03 (SMDR) / 04 (MCI) ] ➉ Device Number of Error detected client PC Kind of Error Details on Detected Error ~ Not used b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b0-b7 : (Hex) 01=SUPER SERVER 02=MAT 03=SMDR 04=MCI 05=OAI 06=PMS 07=MIS 9 b0-b7: (Hex) Device Number of error detected Client PC. If the Machine Number is not determined, “FF” is output. b0-b7: (Hex)...
Page 254
NDA-24238 CHAPTER 3 Page 227 Revision 3.0 SYSTEM MESSAGES [When =05 (OAI) / 07 (MIS) ] ➉ Faulty Logical Port No. (Hex) Error Kind (ERRK) ~ Not used b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 Table 3-3 Error Kind (ERRK) Output Data Error Situation Required Check 01H SEND Execution Error TCP/IP connection is down because the text is not transmit- ted continuously.[1] Check the TCP/IP Transmission capacity on the UAP side is proper or not. [2] Check the operation status on the UAP side is normal....
Page 255
CHAPTER 3 NDA-24238 Page 228 Revision 3.0 SYSTEM MESSAGES This message displays when the LAN Interface Connection Failure, detected in Message [26-V], recovers. The message displays when the LAN Interface Connection Failure is restored. The first data is normally sent/re- ceived by the recovered application equipment. ➀-➃ IP Address for external equipment in which error has been detected. (Hex.) ➄, ➅ Port No. (Client Port No.) (Hex.) ➆ Socket No. (Used Socket No.) (Hex.) ➇ Error Code (TCP/IP Error Code)...
Page 256
NDA-24238 CHAPTER 3 Page 229 Revision 3.0 SYSTEM MESSAGES ➈ Application Type [When ➈ ➈➈ ➈=03 (SMDR) / 04 (MCI) ] ➉ Device Number of recovered client PC Recovery Information b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b0-b7: (Hex) 01=SUPER SERVER 02=MAT 03=SMDR 04=MCI 05=OAI 06=PMS 07=MIS b0-b7: (Hex) Device Number of recovered Client PC for external LAN Interface. b0-b7: (Hex) 01=Recovered 02~FF=Not defined 11
Page 257
CHAPTER 3 NDA-24238 Page 230 Revision 3.0 SYSTEM MESSAGES This message displays when the MUX (PH-PC36) card, whose clock function was detected as faulty, is recov- ered. ➀ Unit, MG number for MUX card, which recovered from a clock failure ➁ RLS Data 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b4 b3 b2 b1 b0 b7 b3 b2 b1 b0 Default...
Page 258
NDA-24238 CHAPTER 3 Page 231 Revision 3.0 SYSTEM MESSAGES This message displays when an abnormal state is detected temporarily on the SDT (PA-SDTA/B) card. ➀ MG (Module Group) ➁ Details on alarm Note:Alarm-detected HW is specified in ➂ (next page). 1: X0XX 00XX XXXX XX00 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b0 b7 b4 b3 b2 b1 b0 Default Alarm:...
Page 259
CHAPTER 3 NDA-24238 Page 232 Revision 3.0 SYSTEM MESSAGES ➂ Alarm-detected HW Note:This data displays only when b4 is “1” and b3 is “0” in data ➁. Repair Procedure Basically, fault repair work is not required by the display of this message. However, if the message is created frequently, it is recommended that the repair work be performed as shown in the message [33-C] SDT Alarm Trouble. b7 b6 b5 b4 b3 b2 b1 b0 The data here specifies the HW, on which any of the VC-11 Path Trouble was detected in data ➁...
Page 260
NDA-24238 CHAPTER 3 Page 233 Revision 3.0 SYSTEM MESSAGES This message displays when a grave failure occurs on the SDT (PA-SDTA/B) card. If this is issued, remember the ACT/STBY change of the SDT card may be followed, as a result of fault detection in the optical fiber line (see [33-E] message). ➀ MG (Module Group) ➁ Details on alarm Note:Fault repair procedure on each alarm is shown on the next page. 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000...