CHAPTER 3 NDA-24238
Page 234
Revision 3.0
SYSTEM MESSAGES
Repair Procedure
Depending on the fault status shown in data 
➁, perform necessary repair work:
(1) Hardware Failure/Onboard Power Alarm
SDT (PA-SDTA/B) card is faulty. Replace the card with a spare by referring to Chapter 4, Section 3.3.3,
SDT Card Replacement Procedure.
(2) Optical Line Failure
Diagnosis: In addition to this alarm, is the “PCM Loss” alarm also indicated?
YES→Optical line side is faulty.
Verify that the SDT card in the distant...

Page 262

NDA-24238 CHAPTER 3
Page 235
Revision 3.0
SYSTEM MESSAGES
(6) Receiving Path Failure/Receiving Path Error
Abnormal state is detected in the process of multiplexing the “Receive” signals. To restore this, perform
the following:
STEP 1 Initialization of SDT card (distant node)
Initialize the SDT card in the distant node, and observe the situation. If the fault is not restored,
proceed with STEP 2.
STEP 2 Initialization of SDT card (self-node)
Initialize the SDT card in the self-node, and observe the...

Page 263

CHAPTER 3 NDA-24238
Page 236
Revision 3.0
SYSTEM MESSAGES
This message displays when the SDT (PA-SDTA/B) card or optical fiber line, which was once detected as
faulty, recovers.
➀ MG (Module Group)
➁ Details on the fault
1: X0XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b0
b7 b4 b3 b2 b1 b0
Default Alarm:
NON33-DSDT Alarm RestoreDefault...

Page 264

NDA-24238 CHAPTER 3
Page 237
Revision 3.0
SYSTEM MESSAGES
This message displays when the ACT/STBY of the SDT (PA-SDTA) card is changed over as a result of fault
detection in the optical fiber line. When the ACT/STBY change cannot be performed, this message also indi-
cates the cause for the changeover execution failure.
➀ MG (Module Group)
➁ Detailed information
➂ Cause for changeover execution failure
Repair Procedure
Once this message displays, be sure to check other messages, such as [33-C] SDT Alarm...

Page 265

CHAPTER 3 NDA-24238
Page 238
Revision 3.0
This page is for your notes. 

Page 266

NDA-24238 CHAPTER 4
Page 239
Revision 3.0
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
CHAPTER 4 Unit/Circuit Card Replacement Procedure
1. LPM Accommodating Unit/Circuit Card Replacement Procedure
This section explains how to replace unit/circuit cards mounted in the LPM.
1.1 Precaution
 Use this procedure to replace a faulty unit/circuit card with a spare or to check a spare card.
 There are functional switches (having set the default switch) on some of the circuit cards to be re-
placed. As for switch...

Page 267

CHAPTER 4 NDA-24238
Page 240
Revision 3.0
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
Figure 4-1   Circuit Card Mounting Face Layout of LPM Note:
In place of PZ-IO27, the CPR may be equipped with PZ-IO28, which does not have the MB
(Make-busy) key.
12
34
567
8
OFF
12
34
567
8
OFF
12
34
OFF
MBR
FDD ON
OFF
PALM
ON
OFF OUT PWR
IN PWR5AHDD SW
MB
SYSTEM SELECT0
SENSE SYSTEM SELECT1
SYSTEM SELECT2
CPURST
SLOT No.    0 1 2 3 4 5 6 STATUS IMG1 IMG2 IMG3 CPUOPE
WDTIMG0
ON
ON
ON4C026AE
12
34
567
8
OFF
12
34
567
8
OFF...

Page 268

NDA-24238 CHAPTER 4
Page 241
Revision 3.0
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
1.3 Operating Procedures
The following paragraphs provide operating procedures to replace unit/circuit cards of the LPM. Perform
the operations that correspond to each Reference Item specified in Table 4-1.
Table 4-1  LPM Unit/Circuit Cards and Reference Items
UNIT/CIRCUIT CARD REFERENCE ITEM REMARKS
CPRSection 1.3.1, CPR Replacement ProcedureCPU, ISAGT, 
LANI
EMA CardSection 1.3.2, EMA Card Replacement Procedure
IOC...

Page 269

CHAPTER 4 NDA-24238
Page 242
Revision 3.0
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
1.3.1 CPR Replacement Procedure
This section explains how to replace the Control Processor Rack (CPR). Before
starting the procedures, make a backup copy of the main data, such as office data,
Call Forwarding (CF) data and Speed Calling (SPD) data, on to the hard disk of the
HFC. Figure 4-2 shows the front view of the CPR. Operate the related keys and con-
nectors to replace the CPU with a new one. Using a Phillips...

Page 270

NDA-24238 CHAPTER 4
Page 243
Revision 3.0
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
Figure 4-3   How to Replace the CPU
..... .....
12
34
567
812
34
567
812
345A
SLOT No.    0 1 2 3
45 6
26E
..... .....
12
34
567
812
34
567
8
12
345A
SLOT No.   
0
1
2
3
4
5
6
26E
CPR
LPM
PBX 