CHAPTER 3 NDA-24238
Pag e 6 4
Revision 3.0
SYSTEM MESSAGES
This message displays when the changeover of the TSW system is executed.
➀ACT side Speech Path (TSW) after 
changeover
➁ Reason for changeover
1: XXXX 0000 XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 XXXX XXXX
➀  ➁ ➂  ➃ ➄  ➅ ➆  ➇ ➈  ➉
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b0
b7 b6 b5 b4 b3 b2 b1 b0
Default Alarm:
NON1-TTSW ACT Change...

Page 92

NDA-24238 CHAPTER 3
Page 65
Revision 3.0
SYSTEM MESSAGES
➂~➅ Status of ACT side TSW card
➆~➉ Status of ST-BY side TSW card
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b0-b3, b4-b7: The status of TSW card in each MG (00~07)
0000 = Normal
0001 = Abnormal (Impossible to make links)
➂MG00 MG01
➃MG02 MG03
➄MG04 MG05
➅MG06 MG07
b7-b4 b3-b0
b0-b3, b4-b7: The status of TSW card in each MG (00~07)
0000 = Normal
0001 = Abnormal (Impossible to make links)
➆MG00 MG01
➇MG02 MG03
➈MG04 MG05
➉MG06 MG07
b7-b4 b3-b0 

Page 93

CHAPTER 3 NDA-24238
Pag e 6 6
Revision 3.0
SYSTEM MESSAGES
This message displays when DLKC data transfer failure (temporary), shown in message [1-V], occurs more
than 16 times an hour. At this time, the faulty DLKC card is down and its switching network automatically
changes over.
➀ System status of faulty DLKC card
➁ Error Code
➂ Details on Switching Network
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7:...

Page 94

NDA-24238 CHAPTER 3
Page 67
Revision 3.0
SYSTEM MESSAGES
This message displays when a data sending error or no answer error occurs at the time of data transfer from
CPU to DLKC card.
➀ System status of faulty DLKC card
➁ Error Code
➂ Details on Switching Network
Note:This data displays when the STBY DLKC card is detected as faulty.
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000...

Page 95

CHAPTER 3 NDA-24238
Pag e 6 8
Revision 3.0
SYSTEM MESSAGES
This message displays when a failure such as internal clock down occurred to PLO is restored.
➀ Restoration of PLO fault
➁ Current Status of PLO card
➂ Current Status of PLO card
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b4 b1 b0
Default Alarm:...

Page 96

NDA-24238 CHAPTER 3
Page 69
Revision 3.0
SYSTEM MESSAGES
This message displays when a C-level program abnormal state is detected as permanent. When the Port Mi-
croprocessor (PM) on an LC/TRK card detects the abnormal state, the PM places the card into make-busy sta-
tus. If the failure occurs more than 15 times an hour, the system judges the failure as permanent and issues the
this system message.
➀Faulty Circuit Card Mounting 
Location
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000...

Page 97

CHAPTER 3 NDA-24238
Pag e 7 0
Revision 3.0
SYSTEM MESSAGES
This message displays when C-level program is detected as abnormal by the Port Microprocessor (PM) mount-
ed on an LC/TRK card. If the failure occurs less than 15 times/hour, and a B-monitor/Initial restart executes
as the result, the failure is judged as temporary and this message is created.
➀Faulty Circuit Card Mounting 
Location
➁ PM Restart Type
Note:B-monitor Restart: Ports whose link has already been established remain connected. Ports...

Page 98

NDA-24238 CHAPTER 3
Page 71
Revision 3.0
SYSTEM MESSAGES
At the periodic interval, the CPU sends diagnosis data to the Port Microprocessor (PM) on LC/TRK cards in
order to monitor the PM. If the CPU cannot receive the return data within a predetermined period of time, the
system displays this data. When the failure is detected more than 15 times per hour, the failure is judged as
permanent.
➀ Faulty Circuit Card Location
Reference: See Chapter 5, Section 6.2, for the repair procedure.
1: XX00 0000 0000...

Page 99

CHAPTER 3 NDA-24238
Pag e 7 2
Revision 3.0
SYSTEM MESSAGES
At the periodic interval, the CPU sends diagnosis data to the Port Microprocessor (PM) on LC/TRK cards in
order to monitor the PM. If the CPU cannot receive the return data within a predetermined period of time, the
system displays this data. When the failure is detected less than 15 times per hour, the failure is judged as tem-
porary.
➀ Faulty Circuit Card Location
➁ PM Restart Type
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000...

Page 100

NDA-24238 CHAPTER 3
Page 73
Revision 3.0
SYSTEM MESSAGES
This message displays when over current of the operating power (DC-48V) is supplied from the ATI/ELC cir-
cuit card to the Attendant Console/Dterm. When this fault occurs, the related circuit card is placed into make-
busy state and stops supplying power.
➀ Location of faulty PM
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000...