Page 101

CHAPTER 3 NDA-24238
Pag e 7 4
Revision 3.0
SYSTEM MESSAGES
This message displays when a wire of the line between the LC circuit card and the telephone set is short-
circuited with ground.
➀ Location of faulty circuit card
➁ Location of faulty circuit card
Note:This message displays when the specific LC card providing the above function is used.
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000...

Page 102

NDA-24238 CHAPTER 3
Page 75
Revision 3.0
SYSTEM MESSAGES
This message displays when the DTI card detects an abnormal state of a digital line but this failure has no in-
fluence on the speech path. When the status worsens, the system issues [3-I] Digital Line Failure message.
➀ Location of PM (LENS) with a 
fault
➁ Kind of fault
➂ Time Slot No. of fault (This data is 
valid only when the kind of fault is 
08H.)
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂ 
4: 0000 0000 0000...

Page 103

CHAPTER 3 NDA-24238
Pag e 7 6
Revision 3.0
SYSTEM MESSAGES
This message displays after [3-H] Digital Line Warning lasts in the DTI card over the particular time. This
failure may cause a speech path fault to the DTI card.
➀ Location of faulty PM
➁ Kind of fault
➂ Location of faulty circuit card (This 
data is valid when 
➁ is 0FH)
➃ Location of faulty circuit card (This 
data is valid when 
➁ is 0FH)
1: XXXX 0000 XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
➀ ➁ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃ ➂ ➃...

Page 104

NDA-24238 CHAPTER 3
Page 77
Revision 3.0
SYSTEM MESSAGES
This message displays when a digital line fault is restored.
➀ Location of faulty line
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
Default Alarm:
NON3-JDigital Line RestoreDefault Grade:
0Grade Modified: Lamp Modified:
b0-b4: Group No. 
b5, b6: Unit No. (0-3)...

Page 105

CHAPTER 3 NDA-24238
Pag e 7 8
Revision 3.0
SYSTEM MESSAGES
This message displays when a Ready Failure occurs in both systems as a result of the TSW card having a failure
or the card is not mounted properly.
➀Unit and MG number of fault 
detection
Reference: See Chapter 5, Section 5.3, for the repair procedure.
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000...

Page 106

NDA-24238 CHAPTER 3
Page 79
Revision 3.0
SYSTEM MESSAGES
This message displays when a Ready Failure occurs in one of the dual systems because the TSW card fails or
the card is not mounted properly.
➀Unit and MG number of fault 
detection
Reference: See Chapter 5, Section 5.4, for the repair procedure.
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000...

Page 107

CHAPTER 3 NDA-24238
Pag e 8 0
Revision 3.0
SYSTEM MESSAGES
This message displays when I/O Ready Failure occurs on a DLKC card.
➀Details on faulty DLKC card
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b0
Default Alarm:
MN4-QDLKC Ready FailureDefault Grade:
3Grade Modified: Lamp Modified:
b0: 0/1 = No. 0 system/No. 1 system
b7: 0/1 = ACT/STBY 

Page 108

NDA-24238 CHAPTER 3
Page 81
Revision 3.0
SYSTEM MESSAGES
This message displays when the MUX (PH-PC36) card has a Ready Failure in one of the dual systems. When
the card is not ready for service function because of the failure or because the card is not mounted properly,
the system creates this message.
➀Unit and MG number for MUX 
card with ready fault
➁MG and system number for faulty 
MUX card
Reference: See Chapter 5, Section 4.3 and Section 4.4, for the repair procedure.
1: XXXX 0000 0000 0000 2: 0000...

Page 109

CHAPTER 3 NDA-24238
Pag e 8 2
Revision 3.0
SYSTEM MESSAGES
This message displays when the MUX (PH-PC36) card has a Ready Failure in both of the dual systems. When
the card is not ready for service function because of the failure or because the card is not mounted properly,
the system creates this system message.
➀Unit and MG number for MUX 
card with the ready fault
➁MG and system number for faulty 
MUX card
Note 1:Though this message indicates the Ready Failure in both systems, the information displayed...

Page 110

NDA-24238 CHAPTER 3
Page 83
Revision 3.0
SYSTEM MESSAGES
This message displays when a PCI card failure occurs.
➀ Fault detection on PCI card
➁ Error status on PCI slot 0
➂ Error status on PCI slot 1
➃ Not used
1: 0X0X 0X0X 0X00 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂ ➃ ➄
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b3 b2 b1 b0
b7 b1 b0
b7 b1 b0
Default Alarm:
MN4-UPCI Card FailureDefault...