Home > NEC > Communications System > NEC Neax 2400 Imx System Operations And Maintenance Manual

NEC Neax 2400 Imx System Operations And Maintenance Manual

Here you can view all the pages of manual NEC Neax 2400 Imx System Operations And Maintenance Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 71

CHAPTER 3 NDA-24238
Pag e 4 4
Revision 3.0
SYSTEM MESSAGES
This message displays when a fault has occurred to the clock oscillator in the CPU.
➀ Self-CPU Restart Information
➁ Male-CPU Restart Information (FF 
H: not mounted)
➂ Related Call Information
Reference: See Chapter 5, Section 6.2, for the repair procedure.
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9:...

Page 72

NDA-24238 CHAPTER 3
Page 45
Revision 3.0
SYSTEM MESSAGES
C-level infinite loop is a state where a clock-level program, running under clock interrupt disable state, is in
an infinite loop. This message displays when the counter value to check the normality of the processing has
become abnormal.
➀ Self-CPU Restart Information after 
clock fault occurrence
➁ Mate-CPU Restart Information
➂ NMI Factor
Reference: See Chapter 5, Section 6.2, for the repair procedure.
0-E C-level Infinite Loop
1: XXXX XXXX XXXX...

Page 73

CHAPTER 3 NDA-24238
Pag e 4 6
Revision 3.0
SYSTEM MESSAGES
➃ System Controlling Port B
➄ CPU Alarm
➅ CPU Changeover Factors
➆ System ALM
➇ Data Analyzed by NEC Engineers b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b0: 0/1 = Timer 2 Gate ON/OFF
b1: 0/1 = Speaker Gate ON/OFF
b2: 0/1 = Parity Check Enable/MASK
b3: 0/1 = Channel Check Enable/MASK
b4: 0/1 = -/RAM Refresh Pulse Output State
b5: 0/1 = -/Timer 2 Output State
b6: 0/1 = -/Channel Check Error...

Page 74

NDA-24238 CHAPTER 3
Page 47
Revision 3.0
SYSTEM MESSAGES
This message displays when a CPU memory read/write error occurs.
➀Information on Self-CPU Restart 
after detection of a clock fault
➁ Mate-CPU Restart Information
➂ NMI Factor
Reference: See Chapter 5, Section 6.2, for the repair procedure.
0-F Memory Failure
1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
 
➀ ➁ ➂ ➃ ➄ ➅ ➆
➇
4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX
➇
7: XXXX XXXX XXXX XXXX 8: XX00...

Page 75

CHAPTER 3 NDA-24238
Pag e 4 8
Revision 3.0
SYSTEM MESSAGES
➃ System Controlling Port B
➄ CPU Alarm
➅ CPU Changeover Factors
➆ System ALM
➇ Data Analyzed by NEC Engineers b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b0: 0/1 = Timer 2 Gate ON/OFF
b1: 0/1 = Speaker Gate ON/OFF
b2: 0/1 = Parity Check Enable/MASK
b3: 0/1 = Channel Check Enable/MASK
b4: 0/1 = -/RAM Refresh Pulse Output State
b5: 0/1 = -/Timer 2 Output State
b6: 0/1 = -/Channel Check Error...

Page 76

NDA-24238 CHAPTER 3
Page 49
Revision 3.0
SYSTEM MESSAGES
This message displays when a B-level infinite loop failure occurs.
➀Information on Self-CPU Restart 
after detection of a clock fault
➁ Mate-CPU Restart Information
➂ B-level Infinite Loop
➃ Data Analyzed by NEC Engineers
Reference: See Chapter 5, Section 6.2, for the repair procedure.
0-F Memory Failure
1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
➀ ➁➂ 
➃
4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX...

Page 77

CHAPTER 3 NDA-24238
Pag e 5 0
Revision 3.0
SYSTEM MESSAGES
This message displays when, in the CPU program processing, the counter value to check the normality of the
processing has become abnormal.
➀ Self-CPU Restart Information
➁ Mate-CPU Restart Information (FF 
H: not mounted)
➂
➃
 Data Analyzed by NEC Engineers
Reference: See Chapter 5, Section 6.2 and Section 6.3, for the repair procedure.
1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
➀ ➁ ➂ ➃ ➃ ➃
4: XXXX XXXX XXXX XXXX 5: XXXX...

Page 78

NDA-24238 CHAPTER 3
Page 51
Revision 3.0
SYSTEM MESSAGES
This message displays when a fault, such as the Clock down or C-level infinite loop error, has occurred.
➀ Mate-CPU Restart Information
Reference: See Chapter 5, Section 6.2 and Section 6.3, for the repair procedure.
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b3 b2 b1 b0
Default...

Page 79

CHAPTER 3 NDA-24238
Pag e 5 2
Revision 3.0
SYSTEM MESSAGES
This message displays when the system is interrupting abnormally in the processing.
➀ Self-CPU Restart Information
➁ Mate-CPU Restart Information (FF 
H: not mounted)
➂
➃
 Data Analyzed by NEC Engineers
Reference: See Chapter 5, Section 6.2 and Section 6.3, for the repair procedure.
1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
➀ ➁ ➂ ➃ ➃ ➃ ➃
4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX
➃➃➃
7: XXXX...

Page 80

NDA-24238 CHAPTER 3
Page 53
Revision 3.0
SYSTEM MESSAGES
This message displays when link information cannot be written into the switch memory of the TSW in both
systems.
➀TSW system in which a fault is 
detected
➁ Status at the time of fault detection
➂ Data Analyzed by NEC Engineers
Reference: See Chapter 5, Section 5.3, for the repair procedure.
1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000...
Start reading NEC Neax 2400 Imx System Operations And Maintenance Manual