CHAPTER 3 NDA-24238
Pag e 8 4
Revision 3.0
SYSTEM MESSAGES
➄ Error status on PCI slot 3
Note 1:Physical Connection Error
 Ethernet cable is disconnected.
 Ethernet cable has short-circuited.
 Ethernet straight/cross cable selection error
Note 2:Hardware Fault
 Transmitter failure
 Controller lock-up b7 b1 b0
b0: 0/1 = -/Physical connection error Note 1
b1: 0/1 = -/Hardware Fault Note 2 

Page 112

NDA-24238 CHAPTER 3
Page 85
Revision 3.0
SYSTEM MESSAGES
This message displays when the PCI card, which was detected as faulty, is recovered.
➀ Detection of PCI restoration
➁Details on error restoration (PCI 
slot 0)
➂Details on error restoration (PCI 
slot 1)
➃Not used
1: 0X0X 0X0X 0X00 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂ ➃ ➄
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b3 b2 b1 b0
b7 b0...

Page 113

CHAPTER 3 NDA-24238
Pag e 8 6
Revision 3.0
SYSTEM MESSAGES
➄Details on error restoration (PCI 
slot 3)
Note:Physical Connection Error
 Ethernet cable is disconnected.
 Ethernet cable has short-circuited.
 Ethernet straight/cross cable selection error b7 b0
b0: 0/1 = -/Physical connection error restoration Note 

Page 114

NDA-24238 CHAPTER 3
Page 87
Revision 3.0
SYSTEM MESSAGES
This message displays when any of the following faults are detected:
 Power failure
 Fuse blowing
 In-Frame abnormal temperature
➀ Probable cause for failure
➁Frame in which a fault is detected
➂ Factor of failure
Reference: See Chapter 5, Section 8, for the repair procedure.
1: XX00 XXXX 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀  ➁ ➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8:...

Page 115

CHAPTER 3 NDA-24238
Pag e 8 8
Revision 3.0
SYSTEM MESSAGES
This message displays when a fault in either the ringer or howler tone occurs in the PWR card.
➀Unit and MG number of fault 
detection
➁ Kind of fault
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b2 b1 b0
b7 b1 b0
Default Alarm:
MN6-BRGU & Howler FailureDefault Grade:
3Grade...

Page 116

NDA-24238 CHAPTER 3
Page 89
Revision 3.0
SYSTEM MESSAGES
This message displays when the CPU usage (occupancy) rate exceeds the value assigned to ASYD, SYS1, In-
dex 56, and the call origination from the pre-selected group of stations is restricted (i.e., Line Load Control is
set). This system message is always indicated as 0.
1: 0000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000...

Page 117

CHAPTER 3 NDA-24238
Pag e 9 0
Revision 3.0
SYSTEM MESSAGES
This message displays when the CPU usage (occupancy) rate becomes lower than the value assigned to ASYD,
SYS1, Index 57, and Line Load Control is cancelled. This system message is always indicated as 0.
1: 0000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
Default Alarm:
NON6-DLine Load Control...

Page 118

NDA-24238 CHAPTER 3
Page 91
Revision 3.0
SYSTEM MESSAGES
This message displays to indicate the result of Bad Call Notification.
➀ 
When type of connection is Station connection
➁ - ➃ Station number (see table)
➄ The called station number
1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: 0000 0000 0000 0000
➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉11
12
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3...

Page 119

CHAPTER 3 NDA-24238
Pag e 9 2
Revision 3.0
SYSTEM MESSAGES
➅ - ➇ Called station number (See 
table)
➈ Time Slot Number of Link 1 
➉ Not used
 Time Slot Number of Link 2 
 Not used
When type of connection is Trunk connection
➁ - ➃ Station number (See table)
➄ Remote Route No.
➅ Remote Route No. b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b3 b2 b1 b0
b4-b7b0-b3
➅DC0 DC1
➆DC2 DC3
➇DC4 DC5
11
12
b4-b7 b0-b3
➁DC0 DC1
➂DC2 DC3
➃DC4 DC5
b0-b5: Route No. (1-63)
b6: OP
0/1 = Data in...

Page 120

NDA-24238 CHAPTER 3
Page 93
Revision 3.0
SYSTEM MESSAGES
➆ Called Trunk No.
➇ Not used
➈ Time Slot Number of Link 1 
➉ Not used
 Time Slot Number of Link 2 
 Not used b7 b6 b5 b4 b3 b2 b1 b0
b0-b7: Trunk No. 
11
12 