NEAX2400 IMX Hotel Feature Programming Manual ND-70284 (E), Issue 2 Page 7 NUMBERING PLAN 19 Call Back (Cancel) Entry Number is “11” 2000 – 2018 4-digit Administration Station Number 3000 – 3011 4-digit Guest Station Number 4 Vacant Numbers 5 6 7 80 Vacant Numbers 81 Access to Area A Route Number: 2 82 Access to Area B Route Number: 3 83 Access to Area C Route Number: 4 84 Access to Area D Route Number: 5 85 Access to Area E Route Number: 6 86 Vacant Numbers 87 88 Access to Paging Equipment Route Number:...
Page 22
NEAX2400 IMX Hotel Feature Programming Manual Page 8ND-70284 (E), Issue 2 NUMBERING PLAN Commands Related to the Numbering Plan This section explains the commands related to the Numbering Plan and also explains command assignment procedure. For details of command, refer to the NEAX2400 IMX Office Data Specification Manual. 1. ASYD (Assignment of System Data) The system data pertaining to the Numbering Plan is as follows: SYS1 INDEX 160 b6 This data is for determining whether the Numbering Plan...
Page 23
NEAX2400 IMX Hotel Feature Programming Manual ND-70284 (E), Issue 2 Page 9 NUMBERING PLAN Commands Related to the Numbering Plan (cont’d) b.) When the Table is to be provided separately for Administration and Guest stations. (b 6 = 0) Note: Administration stations can call Guest stations, but calls from Guest stations to Administration stations are restricted. A call from a Guest Station to a predetermined Administration Station is allowed via Same Number Access (Split Access) service. SYS1 INDEX 161...
Page 24
NEAX2400 IMX Hotel Feature Programming Manual Page 10ND-70284 (E), Issue 2 NUMBERING PLAN Commands Related to the Numbering Plan (cont’d) 5. ASPS (Assignment of Special Access Code for Same Number Access) When Split Access (Same Number Access) is required, these commands are used to specify the kind of service to be executed or the route to be accessed when a Special Access Code or Trunk Access Code is dialed. 6. ASPF (Assignment of Special Access Code for Floor Service) This command is used to assign...
Page 25
NEAX2400 IMX Hotel Feature Programming Manual ND-70284 (E), Issue 2 Page 11 NUMBERING PLAN Examples of Numbering Plan Data Assignments (cont’d) Entry Procedure: START ASYD AANP SYS1INDEX 160, b6 = 0 Numbering Plan Development Table is provided separately for Administration and Guest. INDEX 161, b 6 = 0 Use of “#” code in the Timing Start Service is made effective. INDEX 165, b 7 = 1 Floor Service is provided. With respect to the 1st digit code (1ST DC), assign Number of Necessary Digits (NND) as...
Page 26
NEAX2400 IMX Hotel Feature Programming Manual Page 12ND-70284 (E), Issue 2 NUMBERING PLAN Examples of Numbering Plan Data Assignments (cont’d) AGSP ASPS With respect to the Access Code (ACC) assign service features as follows: ACC SRVSIDNo.KIND 0SSC57 0 0 8SSC56 0 – ACC SRV RT 9OGC1 With respect to the data assigned by AASP and AGSP, assign service features as follows: No. FSRVSIDSTN 00SSC 2 – 0 1 STN – 4000 Assign the station data of Administration stations. Also, assign the data for floor service...
Page 27
NEAX2400 IMX Hotel Feature Programming Manual ND-70284 (E), Issue 2 Page 13 DESCRIPTION OF SERVICE FEATURES CHAPTER 3 DESCRIPTION OF SERVICE FEATURES Hotel Service Features This section explains each Hotel service feature by the following items: General Description Operating Procedure Service Conditions Assignment Procedure General Description This item explains a general description of the service feature. Operating Procedure This item explains the procedure to be followed for receiving a...
Page 28
NEAX2400 IMX Hotel Feature Programming Manual Page 14ND-70284 (E), Issue 2 This page is for your notes.
Page 29
NEAX2400 IMX Hotel Feature Programming Manual ND-70284 (E), Issue 2 Page 15 Automatic Wake-Up A-10 A-10 Automatic Wake-Up General Description This service feature allows the system to be programmed to automatically call guest rooms at specified times. Upon answering, the guest is connected to a recorded announcement or music source. A printout of unanswered or blocked wake-up attempts for guest rooms is provided at the Hotel printer. This feature can be activated from the guest room stations,...
Page 30
NEAX2400 IMX Hotel Feature Programming Manual Page 16ND-70284 (E), Issue 2 A-10 Automatic Wake-Up Operating Procedure (cont’d) To set AUTOMATIC WAKE-UP from a Regular Administration Station: Only separate set and cancel codes will operate from a regular administration station. To cancel AUTOMATIC WAKE-UP from a Regular Administration Station: Only separate set and cancel codes will operate from a regular administration station. To set AUTOMATIC WAKE-UP from a Special Administration Station: Only...