Page 21

NEAX2400 IMX Hotel Feature Programming Manual
ND-70284 (E), Issue 2
Page 7
NUMBERING PLAN
19 Call Back (Cancel) Entry Number is “11”
2000 – 2018 4-digit Administration Station Number
3000 – 3011 4-digit Guest Station Number
4
Vacant Numbers 5
6
7
80 Vacant Numbers
81 Access to Area A Route Number: 2
82 Access to Area B Route Number: 3
83 Access to Area C Route Number: 4
84 Access to Area D Route Number: 5
85 Access to Area E Route Number: 6
86
Vacant Numbers
87
88 Access to Paging Equipment Route Number:...

Page 22

NEAX2400 IMX Hotel Feature Programming Manual
Page 8ND-70284 (E), Issue 2
NUMBERING PLAN
Commands Related to the Numbering Plan
This section explains the commands related to the Numbering Plan and also explains command assignment
procedure. 
For details of command, refer to the NEAX2400 IMX Office Data Specification Manual.
1. ASYD (Assignment of System Data)
The system data pertaining to the Numbering Plan is as follows:
SYS1 INDEX 160 b6
This data is for determining whether the Numbering Plan...

Page 23

NEAX2400 IMX Hotel Feature Programming Manual
ND-70284 (E), Issue 2
Page 9
NUMBERING PLAN
Commands Related to the Numbering Plan (cont’d)
b.) When the Table is to be provided separately for Administration and Guest stations.
(b
6 = 0)
Note:
Administration stations can call Guest stations, but calls from Guest stations to Administration stations are restricted.
A call from a Guest Station to a predetermined Administration Station is allowed via Same Number Access (Split
Access) service.

SYS1 INDEX 161...

Page 24

NEAX2400 IMX Hotel Feature Programming Manual
Page 10ND-70284 (E), Issue 2
NUMBERING PLAN
Commands Related to the Numbering Plan (cont’d)
5. ASPS (Assignment of Special Access Code for Same Number Access)
When Split Access (Same Number Access) is required, these commands are used to specify the kind of
service to be executed or the route to be accessed when a Special Access Code or Trunk Access Code is
dialed.
6. ASPF (Assignment of Special Access Code for Floor Service)
This command is used to assign...

Page 25

NEAX2400 IMX Hotel Feature Programming Manual
ND-70284 (E), Issue 2
Page 11
NUMBERING PLAN
Examples of Numbering Plan Data Assignments (cont’d)
Entry Procedure:
START
ASYD
AANP
SYS1INDEX 160, b6 = 0
Numbering Plan Development Table is provided separately for 
Administration and Guest.
INDEX 161, b
6 = 0
Use of “#” code in the Timing Start Service is made effective.
INDEX 165, b
7 = 1
Floor Service is provided.
With respect to the 1st digit code (1ST DC), assign Number of 
Necessary Digits (NND) as...

Page 26

NEAX2400 IMX Hotel Feature Programming Manual
Page 12ND-70284 (E), Issue 2
NUMBERING PLAN
Examples of Numbering Plan Data Assignments (cont’d)
AGSP
ASPS
With respect to the Access Code (ACC) assign service features 
as follows:
ACC
SRVSIDNo.KIND
0SSC57 0 0
8SSC56 0 –
ACC
SRV RT
9OGC1
With respect to the data assigned by AASP and AGSP, assign 
service features as follows:
No.
FSRVSIDSTN
 00SSC 2 –
0 1 STN –  4000
Assign the station data of Administration stations. Also, assign 
the data for floor service...

Page 27

NEAX2400 IMX Hotel Feature Programming Manual
ND-70284 (E), Issue 2
Page 13
DESCRIPTION OF SERVICE FEATURES
CHAPTER 3 DESCRIPTION OF SERVICE FEATURES
Hotel Service Features
This section explains each Hotel service feature by the following items:
 General Description
 Operating Procedure
 Service Conditions
 Assignment Procedure
General Description
This item explains a general description of the service feature.
Operating Procedure
This item explains the procedure to be followed for receiving a...

Page 28

NEAX2400 IMX Hotel Feature Programming Manual
Page 14ND-70284 (E), Issue 2
This page is for your notes. 

Page 29

NEAX2400 IMX Hotel Feature Programming Manual
ND-70284 (E), Issue 2
Page 15
Automatic Wake-Up A-10
A-10 Automatic Wake-Up
General Description
This service feature allows the system to be programmed to automatically call guest rooms at specified times. Upon
answering, the guest is connected to a recorded announcement or music source. A printout of unanswered or blocked
wake-up attempts for guest rooms is provided at the Hotel printer. This feature can be activated from the guest room
stations,...

Page 30

NEAX2400 IMX Hotel Feature Programming Manual
Page 16ND-70284 (E), Issue 2
A-10 Automatic Wake-Up
Operating Procedure (cont’d)
To set AUTOMATIC WAKE-UP from a Regular Administration Station:
Only separate set and cancel codes will operate from a regular administration station.
To cancel AUTOMATIC WAKE-UP from a Regular Administration Station:
Only separate set and cancel codes will operate from a regular administration station.
To set AUTOMATIC WAKE-UP from a Special Administration Station:
Only...