CHAPTER 3 NDA-24282 Pag e 3 2 Revision 1.0 INSTALLATION Figure 3-15 shows the cable connection between Host and the PBX. Figure 3-15 Connection of Host Note: When the client MIS and IVR/Host are installed in a system together, LAN network directly connected with these terminals should be separated by the router. LANI LANI 10BASE-T (Straight) 10BASE-T (Straight) 10BASE-T (Straight) HUB PKG PIM LPM BASEU
Page 52
NDA-24282 CHAPTER 3 Page 33 Revision 1.0 INSTALLATION Figure 3-16 shows the cable connection between IVR and the PBX. Figure 3-16 Connection of IVR PIM 16LC A0 B0 A1 B1 ~ A15 B15 NoteL2 L1 L2 L1IVR Rosette MDF Installation cable Note:Connector leads (A0, B0) may be connected differently.
Page 53
CHAPTER 3 NDA-24282 Pag e 3 4 Revision 1.0 INSTALLATION 4. SYSTEM START-UP PROCEDURE FOR ADDING ACD FEATURES 4.1 ACD SOFTWARE INSTALLATION This section explains the installation procedure for adding the Built-in ACDP software to the PBX in on-line operation. For more detailed information about start-up procedures before the ACD application software install, see the “Installation Manual”. [Operation Procedure] a. Basic Operating Procedure STEP 1 : By using MEM_HDD command, save all data to both HDDs. STEP...
Page 54
NDA-24282 CHAPTER 3 Page 35 Revision 1.0 INSTALLATION b. When Installing ACD Trunk into Multiple Fusion Nodes (Software installation when the ACD trunk is in- stalled at Fusion Nodes.) (1) At the node that uses the ACDP, the ACD software (Built-in ACDP software) and ACD Option Soft- ware installation is necessary. (2) At the node that accommodates the ACD trunk, only ACD Option Software installation is necessary. Do not install the ACD software. (3) Initialize the node that uses the ACDP after the...
Page 55
CHAPTER 3 NDA-24282 Pag e 3 6 Revision 1.0 INSTALLATION 4.2 BASIC DATA ASSIGNMENT FOR START-UP STEP 1 : Change the system data written in DM. ASYD SYS1 INDEX2 - b0=1 (ACDP mounted) INDEX31 - b0~b3: CM mounting capacity Assign Normally “06”. Note 1 INDEX79 - b6=0 (ACD service is effective) Note 1 INDEX207 - b0=1 (ACDP in system0 is used) b1: ACDP in system1 0/1=Not used/Used INDEX241 - b2=1 (call event process) Note 1 Note 1: When the ACD service is activated via FCCS, this data must be set to all...
Page 56
NDA-24282 CHAPTER 3 Page 37 Revision 1.0 INSTALLATION 5. UPGRADING ACD SYSTEM FROM NEAX2400 ICS TO NEAX2400 IMX Figure 3-17 and Table 3-1 show the requirements when upgrading the CallCenterWorX-Enerprise (ACD) sys- tem from NEAX2400 ICS to 2400 IMX. 5.1 HARDWARE AND SOFTWARE REQUIREMENTS Figure 3-17 Hardware and Software Upgrading Requirements (See Table 3-1.) PBX MAT Router [9]Server MIS DM CPU ACD DMLAN MIS DBClient MIS [3] [1] [2] [4][5] [6] [7][8] ACDP IVR/Host [10] Note 1:[5], [6], [7], [8] are...
Page 57
CHAPTER 3 NDA-24282 Pag e 3 8 Revision 1.0 INSTALLATION Table 3-1 Hardware and Software Upgrading Requirements No.Upgrading Hardware or SoftwareNEAX2400 ICS (before upgrading)NEAX2400 IMX (after upgrading) [1]Generic Software Basic software Standard Service software Optional softwareAll types of system PBX software Release 3 or later Basic software (#1~#11) Internal MAT software (#1~#2) TCP/IP software [2]ACD software SC-2242 PRG-E or SC-2243 PRG-FBuilt-in ACDP software [3]MAT Hardware and...
Page 58
NDA-24282 CHAPTER 3 Page 39 Revision 1.0 INSTALLATION 5.2 UPGRADING PROCEDURE STEP 1 : Print out the existent data in the MIS terminal or save the data as the text file.Note 4 STEP 2 : List up the office data related to the current ACDP. STEP 3 : Shutdown MIS operation following the appropriate procedure. Note 4 STEP 4 : Make busy the CPU (ACDP) card (CP53/CP54) and disconnect all cables connected to cards related to ACD. STEP 5 : Upgrade the PBX hardware following the Upgrade Manual for the PBX. STEP 6...
Page 60
NDA-24282 CHAPTER 4 Page 41 Revision 1.0 CHAPTER 4 SWITCH SETTING OF ACD CIRCUIT CARDS 1. GENERAL This chapter explains the circuit cards related to the NEAX2400 CallCenterWorX-Enterprise (ACD) System which are shown in Table 4-1. Table 4-1 List of ACD Circuit Cards SYMBOL CIRCUIT CARDMOUNTING MODULEREMARKS CPU PA-CP53 PIMU For circuit card type EAPI PH-PC22/PH-PC27 LPRJ-A ALMC PA-AL16 APM For module type APINT PH-PC21 LPRJ-A COPY PA-PC56-A APM CPU PA-CP54 APM CRAM PA-ME34 APM IOC PA-IO02-A APM PBI...