Page 161

CHAPTER 4 NDA-24282 (E)
Pag e 1 42
Revision 1.0
PA-4DATA (4DAT)
(b) LT Connector Lead Accommodation when this circuit card is mounted in PIMB
Figure 4-13   LT Connector Leads Accommodation of PIMB
LT Connector Accommodation
26 
27 
28 
29 
30 
31 
32 
33 
34 
35 
36 
37 
38 
39 
40 
41 
42 
43 
44 
45 
46 
47 
48 
49 
50LT1, 3, 5, 8, 10 Connector1 
2 
3 
4 
5 
6 
7 
8 
9 
10 
11 
12 
13 
14 
15 
16 
17 
18 
19 
20 
21 
22 
23 
24 
2526 
27 
28 
29 
30 
31 
32 
33 
34 
35 
36 
37 
38 
39 
40 
41 
42 
43...

Page 162

NDA-24282 (E) CHAPTER 4
Page 143
Revision 1.0
PA-4DATA (4DAT)
Switch Setting Sheet 
MODULE SLOT NO.SWITCH 
NAMESWITCH SHAPE REMARKS
PIM SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
SW9
SW10ON
12 3 4
ON
12 3 4
ON
12 3 4
ON
12 3 4
ON
12 3 4
ON
12 3 456 7 8
ON
12 3 4
ON
3
2
1
0
ON 

Page 163

CHAPTER 4 NDA-24282 (E)
Pag e 1 44
Revision 1.0
PA-4DATA (4DAT)
SW12
MB DOWN Circuit card make idle.
Switch Setting Sheet  (Continued)
MODULE SLOT NO.SWITCH 
NAMESWITCH SHAPE REMARKS
ON 

Page 164

NDA-24282 (E) CHAPTER 4
Page 145
Revision 1.0
PA-4DATB (DAT)
PA-4DATB (DAT)
1. General Function
The PA-4DATB (DAT) circuit card is used as a Digital Announcement Trunk supporting service features
related to announcement functions such as Automated Attendant, Delay Announcement Attendant,
Announcement Service (for Hotel System). Depending on the switch setting, this circuit card works in one
of the following three modes.
 64-second mode (maximum 4 CHs/card)
 128-second mode (maximum 2 CHs/card)
...

Page 165

CHAPTER 4 NDA-24282 (E)
Pag e 1 46
Revision 1.0
PA-4DATB (DAT)
2. Mounting Location/Condition
The PA-4DATB (DAT) card can be mounted in any universal slot as shown below.
Mounting Module PIMU-A
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Note:      Indicates universal slots for line/trunk circuit cards.
Mounting Module PIME
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Note:      Indicates universal slots for line/trunk circuit cards. 

Page 166

NDA-24282 (E) CHAPTER 4
Page 147
Revision 1.0
PA-4DATB (DAT)
3. Face Layout of Lamps, Switches, and Connectors
The face layout of lamps, switches, and connectors on this circuit card is shown below.
4. Lamp Indications
The contents of lamp indications of this circuit card are shown in the table below.
LAMP COLOR STATE
OPE Green Remains lit while this circuit card is operating.
N-OPE Red Remains lit while this circuit card is in make-busy state.
BL4
BL7GreenLights when the corresponding circuit (No 0...

Page 167

CHAPTER 4 NDA-24282 (E)
Pag e 1 48
Revision 1.0
PA-4DATB (DAT)
5. Switch Settings
Standard settings of switches on this circuit card are shown in the table below.
SWITCHSWITCH 
NO.SETTINGSTANDARD
SETTINGMEANING
MB UP Circuit card make busy.
DOWN×Circuit card make busy cancel.
MB RQ
1-4ONMake busy request on a channel basis
(Channel Designation for Recording/Playback)
OFF×Make busy request cancel on a channel basis
MRCS 0
1
2
3
4
5
6
7
SW1
SW4Each Switch corresponds to each chan-
nel of
DAT: channel
SW1:...

Page 168

NDA-24282 (E) CHAPTER 4
Page 149
Revision 1.0
PA-4DATB (DAT)
SWITCHSWITCH 
NO.SETTINGSTANDARD
SETTINGMEANING
SW5
1
2
3ON Compression Law: µ-law
OFF Compression Law: A-law
4ON To be used as external hold tone source
OFF To be used as announcement equipment
SW6
1ON Single playback of No. 0 channel 
Note 2
OFF Multiple playback of No. 0 channel
2ON Single playback of No. 1 channel 
Note 2
OFF Multiple playback of No. 1 channel
3ON Single playback of No. 2 channel 
Note 2
OFF Multiple playback of No. 2...

Page 169

CHAPTER 4 NDA-24282 (E)
Pag e 1 50
Revision 1.0
PA-4DATB (DAT)
SWITCHSWITCH 
NO.SETTINGSTANDARD
SETTINGMEANING
SW7
1ON Activation of RAM Test
OFF×Normal setting
2ON Port Microprocessor is reset when MBR key is ON.
OFF×Port Microprocessor is not reset when MBR key is ON.
3OFF×Not used
4OFF×Not used
WR UP For recording from the phone jack
DOWN×Normal setting
START
UPWhen starting recording from the phone jack or play-
back.
DOWN×Normal setting
Jumper Setting
SWITCHSWITCH
SHAPESETTING DESCRIPTION
JP0LEFT...

Page 170

NDA-24282 (E) CHAPTER 4
Page 151
Revision 1.0
PA-4DATB (DAT)
6. External Interface
When this card is used as an external music-on-hold source, the following cable connection is required.
Figure 4-15   LT Connector Lead Accommodation (PIMU-A)
EFM
EFM26 
27 
28 
29 
30 
31 
32 
33 
34 
35 
36 
37 
38 
39 
40 
41 
42 
43 
44 
45 
46 
47 
48 
49 
50
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
LT0
PIMC LT Connector Name
Slot No.
 1 
2 
3 
4 
5 
6 
7 
8 
9 
10 
11 
12 
13 
14 
15...