Home > NEC > Communications System > NEC Neax 2400 Imx Callcenterworx Enterprise Acd System Manual

NEC Neax 2400 Imx Callcenterworx Enterprise Acd System Manual

Here you can view all the pages of manual NEC Neax 2400 Imx Callcenterworx Enterprise Acd System Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 131

CHAPTER 4 NDA-24282
Pag e 1 12
Revision 1.0
PA-16ELCH (16ELC)
2. Mounting Location/Condition
The mounting locations of this circuit card and the conditions related to mounting are shown below.
(a) When this circuit card is mounted in PIMA
(b) When this circuit card is mounted in PIMB
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Mounting Module PIMU-A
00
Note:      Indicates that the slots are a universal slot for line/trunk circuit cards. 
 
Mounting Module PIMB
01 02 03 04 05 06...

Page 132

NDA-24282 CHAPTER 4
Page 113
Revision 1.0
PA-16ELCH (16ELC)
3. Face Layout of Lamps, Switches, and Connectors
The face layout of lamps, switches, and connectors of this circuit card is shown below.
4. Lamp Indications
The contents of lamp indications of this circuit card are shown in the table below.
LAMP NAME COLOR STATE
OPEGreen Remains lit while on-line operations are normal.
OFF Off when on-line operations are abnormal.
PWR ALMRed Lights when more than one power supply circuit are abnormal.
OFF Off...

Page 133

CHAPTER 4 NDA-24282
Pag e 1 14
Revision 1.0
PA-16ELCH (16ELC)
5. Switch Settings
Standard settings of various switches on this circuit card are shown in the table below.
Note 1:APR-J/APA-J is an optional device to be connected to Dterm and provides interface for analog terminal.
Note 2:By setting SWO-1 and SWO-7  as explained in the above table, eith e r APR-J /A PA-J or Dat a Adapt er can be used. SWITCH 
NAMESWITCH NO. SETTINGSTANDARD 
SETTINGMEANING
SW0
1
Note 1
Note 2
ONWhen APR-J/APA-J is not...

Page 134

NDA-24282 CHAPTER 4
Page 115
Revision 1.0
PA-16ELCH (16ELC)
SW0-7
SW0-7
ON OFF
ONUp to 16 circuits can be connected. 
Only voice is used.Up to 8 circuits can be connected.
Simultaneous communications of voice and 
data (use of Data Adapter) can be utilized.
Make this setting when using Data Adapter.
OFFUp to 16 circuits can be connected.
Simultaneous communications of voice and 
data (use of APR-J/APA-J) cannot be serviced.
When either data or voice is used by changing 
over with APR-J/APA-J.Up to 8...

Page 135

CHAPTER 4 NDA-24282
Pag e 1 16
Revision 1.0
PA-16ELCH (16ELC)
6. External Interface
Accommodation of the LT connector leads of this circuit card and connecting route diagram are shown be-
low.
(a) LT Connector Lead Accommodation when this circuit card is mounted in PIMA
 When the mode is 16ELC Mode/Single Port Mode.
Figure 4-7   LT Connector Leads Accommodation of PIMU-A (1 of 3)
LT Connector Accommodation
26 
27 
28 
29 
30 
31 
32 
33 
34 
35 
36 
37 
38 
39 
40 
41 
42 
43 
44 
45 
46 
47 
48 
49...

Page 136

NDA-24282 CHAPTER 4
Page 117
Revision 1.0
PA-16ELCH (16ELC)
Figure 4-7  LT Connector Leads Accommodation of PIMU-A (2 of 3)
LT Connector Accommodation
26 
27 
28 
29 
30 
31 
32 
33 
34 
35 
36 
37 
38 
39 
40 
41 
42 
43 
44 
45 
46 
47 
48 
49 
50
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
LT0
PIMA LT Connector Name
Slot No.
LT1, 3, 5, 7, 9, 11 Connector
B8 
B9 
B10 
B11 
B12 
B13 
B14
B15
 
 1 
2 
3 
4 
5 
6 
7 
8 
9 
10 
11 
12 
13 
14 
15 
16 
17 
18 
19 
20 
21 
22 
23...

Page 137

CHAPTER 4 NDA-24282
Pag e 1 18
Revision 1.0
PA-16ELCH (16ELC)
 When the mode is 8DLC Mode/Dual Port Mode.
Figure 4-7  LT Connector Leads Accommodation of PIMU-A (3 of 3)
LT Connector Accommodation
26 
27 
28 
29 
30 
31 
32 
33 
34 
35 
36 
37 
38 
39 
40 
41 
42 
43 
44 
45 
46 
47 
48 
49 
50
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
LT0
PWR
PIMA LT Connector Name
Slot No.
LT1, 3, 5, 7, 9, 11 Connector
Accommodated in *2
1 
2 
3 
4 
5 
6 
7 
8 
9 
10 
11 
12 
13 
14 
15...

Page 138

NDA-24282 CHAPTER 4
Page 119
Revision 1.0
PA-16ELCH (16ELC)
(b) LT Connector Lead Accommodation when this circuit card is mounted in PIMB
 When the mode is 16ELC Mode and the APR-J/APA-J is used.
Figure 4-8   LT Connector Leads Accommodation of PIMB (1 of 3)
LT Connector Accommodation
26 
27 
28 
29 
30 
31 
32 
33 
34 
35 
36 
37 
38 
39 
40 
41 
42 
43 
44 
45 
46 
47 
48 
49 
50LT1, 3, 5, 8, 10 Connector1 
2 
3 
4 
5 
6 
7 
8 
9 
10 
11 
12 
13 
14 
15 
16 
17 
18 
19 
20 
21 
22 
23 
24 
2526 
27...

Page 139

CHAPTER 4 NDA-24282
Pag e 1 20
Revision 1.0
PA-16ELCH (16ELC)
Figure 4-8  LT Connector Leads Accommodation of PIMB (2 of 3)
LT Connector Accommodation
26 
27 
28 
29 
30 
31 
32 
33 
34 
35 
36 
37 
38 
39 
40 
41 
42 
43 
44 
45 
46 
47 
48 
49 
50LT1, 3, 5, 8, 10 Connector1 
2 
3 
4 
5 
6 
7 
8 
9 
10 
11 
12 
13 
14 
15 
16 
17 
18 
19 
20 
21 
22 
23 
24 
2526 
27 
28 
29 
30 
31 
32 
33 
34 
35 
36 
37 
38 
39 
40 
41 
42 
43 
44 
45 
46 
47 
48 
49 
50LT0, 2, 4, 7, 9 Connector...

Page 140

NDA-24282 CHAPTER 4
Page 121
Revision 1.0
PA-16ELCH (16ELC)
 When the mode is 8DLC Mode and the APR-J/APA-J is used.
Figure 4-8  LT Connector Leads Accommodation of PIMB (3 of 3)
LT Connector Accommodation
26 
27 
28 
29 
30 
31 
32 
33 
34 
35 
36 
37 
38 
39 
40 
41 
42 
43 
44 
45 
46 
47 
48 
49 
50LT1, 3, 5, 8, 10 Connector1 
2 
3 
4 
5 
6 
7 
8 
9 
10 
11 
12 
13 
14 
15 
16 
17 
18 
19 
20 
21 
22 
23 
24 
2526 
27 
28 
29 
30 
31 
32 
33 
34 
35 
36 
37 
38 
39 
40 
41 
42 
43 
44 
45 
46 
47...
Start reading NEC Neax 2400 Imx Callcenterworx Enterprise Acd System Manual

Related Manuals for NEC Neax 2400 Imx Callcenterworx Enterprise Acd System Manual

All NEC manuals