Page 131
CHAPTER 4 NDA-24282 Pag e 1 12 Revision 1.0 PA-16ELCH (16ELC) 2. Mounting Location/Condition The mounting locations of this circuit card and the conditions related to mounting are shown below. (a) When this circuit card is mounted in PIMA (b) When this circuit card is mounted in PIMB 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Mounting Module PIMU-A 00 Note: Indicates that the slots are a universal slot for line/trunk circuit cards. Mounting Module PIMB 01 02 03 04 05 06...
Page 132
NDA-24282 CHAPTER 4 Page 113 Revision 1.0 PA-16ELCH (16ELC) 3. Face Layout of Lamps, Switches, and Connectors The face layout of lamps, switches, and connectors of this circuit card is shown below. 4. Lamp Indications The contents of lamp indications of this circuit card are shown in the table below. LAMP NAME COLOR STATE OPEGreen Remains lit while on-line operations are normal. OFF Off when on-line operations are abnormal. PWR ALMRed Lights when more than one power supply circuit are abnormal. OFF Off...
Page 133
CHAPTER 4 NDA-24282 Pag e 1 14 Revision 1.0 PA-16ELCH (16ELC) 5. Switch Settings Standard settings of various switches on this circuit card are shown in the table below. Note 1:APR-J/APA-J is an optional device to be connected to Dterm and provides interface for analog terminal. Note 2:By setting SWO-1 and SWO-7 as explained in the above table, eith e r APR-J /A PA-J or Dat a Adapt er can be used. SWITCH NAMESWITCH NO. SETTINGSTANDARD SETTINGMEANING SW0 1 Note 1 Note 2 ONWhen APR-J/APA-J is not...
Page 134
NDA-24282 CHAPTER 4 Page 115 Revision 1.0 PA-16ELCH (16ELC) SW0-7 SW0-7 ON OFF ONUp to 16 circuits can be connected. Only voice is used.Up to 8 circuits can be connected. Simultaneous communications of voice and data (use of Data Adapter) can be utilized. Make this setting when using Data Adapter. OFFUp to 16 circuits can be connected. Simultaneous communications of voice and data (use of APR-J/APA-J) cannot be serviced. When either data or voice is used by changing over with APR-J/APA-J.Up to 8...
Page 135
CHAPTER 4 NDA-24282 Pag e 1 16 Revision 1.0 PA-16ELCH (16ELC) 6. External Interface Accommodation of the LT connector leads of this circuit card and connecting route diagram are shown be- low. (a) LT Connector Lead Accommodation when this circuit card is mounted in PIMA When the mode is 16ELC Mode/Single Port Mode. Figure 4-7 LT Connector Leads Accommodation of PIMU-A (1 of 3) LT Connector Accommodation 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49...
Page 136
NDA-24282 CHAPTER 4 Page 117 Revision 1.0 PA-16ELCH (16ELC) Figure 4-7 LT Connector Leads Accommodation of PIMU-A (2 of 3) LT Connector Accommodation 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 LT0 PIMA LT Connector Name Slot No. LT1, 3, 5, 7, 9, 11 Connector B8 B9 B10 B11 B12 B13 B14 B15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23...
Page 137
CHAPTER 4 NDA-24282 Pag e 1 18 Revision 1.0 PA-16ELCH (16ELC) When the mode is 8DLC Mode/Dual Port Mode. Figure 4-7 LT Connector Leads Accommodation of PIMU-A (3 of 3) LT Connector Accommodation 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 LT0 PWR PIMA LT Connector Name Slot No. LT1, 3, 5, 7, 9, 11 Connector Accommodated in *2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15...
Page 138
NDA-24282 CHAPTER 4 Page 119 Revision 1.0 PA-16ELCH (16ELC) (b) LT Connector Lead Accommodation when this circuit card is mounted in PIMB When the mode is 16ELC Mode and the APR-J/APA-J is used. Figure 4-8 LT Connector Leads Accommodation of PIMB (1 of 3) LT Connector Accommodation 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50LT1, 3, 5, 8, 10 Connector1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2526 27...
Page 139
CHAPTER 4 NDA-24282 Pag e 1 20 Revision 1.0 PA-16ELCH (16ELC) Figure 4-8 LT Connector Leads Accommodation of PIMB (2 of 3) LT Connector Accommodation 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50LT1, 3, 5, 8, 10 Connector1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2526 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50LT0, 2, 4, 7, 9 Connector...
Page 140
NDA-24282 CHAPTER 4 Page 121 Revision 1.0 PA-16ELCH (16ELC) When the mode is 8DLC Mode and the APR-J/APA-J is used. Figure 4-8 LT Connector Leads Accommodation of PIMB (3 of 3) LT Connector Accommodation 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50LT1, 3, 5, 8, 10 Connector1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2526 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47...