Page 141
CHAPTER 4 NDA-24282 Pag e 1 22 Revision 1.0 PA-16ELCH (16ELC) Figure 4-9 Connecting Route Diagram NEAX2400 IMS A0MDF Rosette A0 B0 B0ELC Dterm
Page 142
NDA-24282 CHAPTER 4 Page 123 Revision 1.0 PA-16ELCH (16ELC) Switch Setting Sheet MODULE SLOT NO.SWITCH NAMESWITCH SHAPE REMARKS PIMU-A SW0 MB DOWN Circuit card make idle.ON 12 3 45678
Page 143
CHAPTER 4 NDA-24282 (E) Pag e 1 24 Revision 1.0 PA-16ELCJ (16ELC) PA-16ELCJ (16ELC) 1. Function This circuit card is a line circuit card which supports the interface of 16 circuits or eight circuits of a 2W- Digital Terminal based on TCM transmission system (Time Compression Multiplex). This circuit card can be used as an eight-circuit voice/data digital line (8DLC Mode) and a 16-circuit voice only digital line circuit (16ELC Mode), and can be connected to any D term of the Dterm Series III. Differences...
Page 144
NDA-24282 (E) CHAPTER 4 Page 125 Revision 1.0 PA-16ELCJ (16ELC) 2. Mounting Location/Condition The mounting locations of this circuit card and the conditions related to mounting are shown below. (a) When this circuit card is mounted in PIMJ (b) When this circuit card is mounted in PIMK Mounting Module PIMU-A 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Note:Indicates universal slots for line/trunk circuit cards. Mounting Module PIMK 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14...
Page 145
CHAPTER 4 NDA-24282 (E) Pag e 1 26 Revision 1.0 PA-16ELCJ (16ELC) 3. Face Layout of Lamps, Switches, and Connectors The face layout of lamps and switches on this circuit card is shown below. 4. Lamp Indications The contents of lamp indications of this circuit card are shown in the table below. Note:When the PALM lamp lights red, observe the following instructions. i) Identify the location where any in-house wires have a short circuit as to all lines which belong to the PA-16ELCJ card whose PALM is on....
Page 146
NDA-24282 (E) CHAPTER 4 Page 127 Revision 1.0 PA-16ELCJ (16ELC) 5. Switch Settings Standard settings of various switches on this circuit card are shown in the table below. Note 1:APR-J/APA-J is an optional device to be connected to Dterm and provides interface for analog terminal. Note 2:By setting SW01-1 and SW01-7 as explained in the table below, either APR-J/APA-J or Data Adapter can be used. SWITCH NAMESWITCH NO.SETTINGSTANDARD SETTINGMEANING SW011 Note 1 Note 2 ON When APR-J/APA-J is not connected....
Page 147
CHAPTER 4 NDA-24282 (E) Pag e 1 28 Revision 1.0 PA-16ELCJ (16ELC) 6. External Interface Accommodation of the LT connector leads of this circuit card and connecting route diagram are shown below. (a) LT Connector Lead Accommodation when this circuit card is mounted in PIMJ When the mode is 16ELC Mode/Single Port Mode. Figure 4-10 LT Connector Leads Accommodation of PIMU-A (1 of 3) LT Connector Accommodation 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49...
Page 148
NDA-24282 (E) CHAPTER 4 Page 129 Revision 1.0 PA-16ELCJ (16ELC) Figure 4-10 LT Connector Lead Accommodation of PIMU-A (2 of 3) LT Connector Accommodation 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 LT0 PIMJ LT Connector Name Slot No. LT1, 3, 5, 7, 9, 11 Connector B8 B9 B10 B11 B12 B13 B14 B15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22...
Page 149
CHAPTER 4 NDA-24282 (E) Pag e 1 30 Revision 1.0 PA-16ELCJ (16ELC) When the mode is 8DLC Mode/Dual Port Mode. Figure 4-10 LT Connector Leads Accommodation of PIMU-A (3 of 3) LT Connector Accommodation 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 LT0 PWR PIMJ LT Connector Name Slot No. LT1, 3, 5, 7, 9, 11 Connector Accommodated in *2 1 2 3 4 5 6 7 8 9 10 11 12 13 14...
Page 150
NDA-24282 (E) CHAPTER 4 Page 131 Revision 1.0 PA-16ELCJ (16ELC) (b) LT Connector Lead Accommodation when this circuit card is mounted in PIMK When the mode is 16ELC Mode and the APR-J/APA-J is used. Figure 4-11 LT Connector Leads Accommodation of PIMK (1 of 3) LT Connector Accommodation 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 LT1, 3, 5, 8, 10 Connector 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2526...