Page 181

CHAPTER 4 NDA-24282 (E)
Pag e 1 62
Revision 1.0
PA-4DTLA (4DTL)
NEAX2400 IMS
B00MDF
G
R
A004DTLModular
JackDTE RS232
B
B10
Y
A10 

Page 182

NDA-24282 (E) CHAPTER 4
Page 163
Revision 1.0
PA-CC98 (ETHER)
PA-CC98 (ETHER)
Ethernet Controller
1. Functional Outline
In the NEAX2400 ICS OAI System, this circuit card supports the functions for interface between the CPU
(IP) circuit card and the external computer. If circuit card type, this circuit card is directly connected with
the CPU card (PA-CP53). If module type, being paired with PA-GT (MBB) card, it connects the Interface
Processor (IP) and the User Application Processor (UAP) through a LAN....

Page 183

CHAPTER 4 NDA-24282 (E)
Pag e 1 64
Revision 1.0
PA-CC98 (ETHER)
2. Circuit Card Mounting Locations/Conditions
The mounting locations and conditions of this circuit card are shown below.
(a) In the case of circuit card type
 When mounting in the PIMU-A
 When mounting in the PIMB
Mounting Module PIMU-A
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Note:      Indicates the mounting locations of this circuit card.
Mounting Module PIMB
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14...

Page 184

NDA-24282 (E) CHAPTER 4
Page 165
Revision 1.0
PA-CC98 (ETHER)
(a) In the case of module type
3. Locations of Lamps, Switches, and Connectors
The locations of lamps, switches, and connectors equipped on this circuit card are shown below.
Mounting Module APM
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23PA-CC98
SW0
BUS LAN FUSE OPE
SW1ERR 
S2 S1 
S3
SW2 

Page 185

CHAPTER 4 NDA-24282 (E)
Pag e 1 66
Revision 1.0
PA-CC98 (ETHER)
4. Lamp Indications
The meaning of indication of each lamp on this circuit card is shown below.
5. Switch Setting
Each switch setting on this circuit card and its meaning are shown in the tables on the following pages.
The CC98 Internet address is set by using the AIPT MAT command. For ICS and IMX, Internet is set only
by the AIPT command. For HDS (IMG) configurations, the AIPT command is used for setting the Internet
address for software...

Page 186

NDA-24282 (E) CHAPTER 4
Page 167
Revision 1.0
PA-CC98 (ETHER)
SWITCHDIP SW 
No.SETTINGDEFAULT 
SETTINGMEANING
SW0
(8 DIP Switches)1ON Sets 0, corresponding to bit 0 of MAC address
OFF Sets 1, corresponding to bit 0 of MAC address
2ON Sets 0, corresponding to bit 1 of MAC address
OFF Sets 1, corresponding to bit 1 of MAC address
3ON Sets 0, corresponding to bit 2 of MAC address
OFF Sets 1, corresponding to bit 2 of MAC address
4ON Sets 0, corresponding to bit 3 of MAC address
OFF Sets 1, corresponding to...

Page 187

CHAPTER 4 NDA-24282 (E)
Pag e 1 68
Revision 1.0
PA-CC98 (ETHER)
SW1 (Continued)
4ON Sets 0, corresponding to bit 11 of MAC address
OFF Sets 1, corresponding to bit 11 of MAC address
5ON×Fixed
6ON×Fixed
7ON×Fixed
8ON×Fixed
[Reference]
Setting of MAC address
On LAN and TCP/IP, this circuit card can have the following 
addresses and ports.
MAC Address: 000032250xxxH (48 bits)
TCP Port Numbers: 16 port numbers of 1024 ~ 1039
The last 12 bits of MAC address must be set by switches 
SW0 and SW1 before starting...

Page 188

NDA-24282 (E) CHAPTER 4
Page 169
Revision 1.0
PA-CC98 (ETHER)
MODULE SLOT SWITCH SWITCH SHAPE REMARKS
SW0
SW1
SW2Fixed for the system12345678ON
12345678ON
0 

Page 189

CHAPTER 4 NDA-24282 (E)
Pag e 1 70
Revision 1.0
PA-GT16 (MBB)
PA-GT16 (MBB)
Memory Bus Buffer
1. Functional Outline
This circuit card is used in the OAI module type for the NEAX2400 IMX and ICS OAI System. It is a circuit
card which repeats the memory bus on PA-CP54 (CPU) card side to ETHER (Ethernet Interface) gate card.
2. Circuit Card Mounting Locations/Conditions
Mounting Module APM
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23PA-GT16
CPU (No.0 Sys) 
(PA-CP54)CPU (No.1 Sys)...

Page 190

NDA-24282 (E) CHAPTER 4
Page 171
Revision 1.0
PA-GT16 (MBB)
3. Locations of Lamps, Switches, and Connectors
The locations of lamps, switches, and connectors equipped on this circuit card are shown below.
4. Lamp Indications
The meaning of indication of each lamp on this circuit card is shown below.
LAMP COLOR MEANING OF INDICATION
OPE Green Remains lit while this circuit card and ETHER card are normally operating
LAN ALM RedLights when the processor in ETHER card has become faulty or when ETHER 
card is...