Page 81

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 51
Analog Caller ID (Class SM) A-125
Service Conditions (cont’d)
c.) When the received numbers of a calling number and calling name exceed the display field, the
decision to put the digits to the right or left may be chosen in system data. An “*” is indicated on
the exceeded digit position.
d.) The display is flashing during termination. It is lit during conversation.
e.) The following are examples of displays when the received...

Page 82

NEAX2400 IMX Business Features and Specifications
Page 52NDA-24221, Issue 3
A-127 Analog Caller ID - Station
A-127 Analog Caller ID - Station
General Description
This feature allows a called station to receive CALLER ID information (time, calling number and name) from
Central Office when a call terminates via the analog COT. The calling number received from the ISDN network,
MF-ANI information received from Central Office with the MF feature or the calling telephone number within the
PBX can change into...

Page 83

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 53
Analog Caller ID - Station A-127
Service Conditions (cont’d)
d.) When the self-address is assigned to the calling ISDN terminal, the self-address is sent. In this
case, the sub-address number is not sent.
e.) This function is not available even if the analog telephone has the function to restrict sending the
calling number on each conversation.
f.) The function to restrict the calling number notification is available only when a...

Page 84

NEAX2400 IMX Business Features and Specifications
Page 54NDA-24221, Issue 3
A-127 Analog Caller ID - Station
Interactions (cont’d)
Note:16LCBY and 8RSTY must be used together for Caller ID.
3. Only one route number can be assigned for each sender and register in a PA-8RSTY card. 

Page 85

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 55
Busy Lamp Field - Flexible B-2
B-2  Busy Lamp Field - Flexible
General Description
This feature provides the Attendant with visual indications of either busy, idle or LINE LOCKOUT [L-3] conditions
for a particular group of stations via a designated lamp field on the Attendant Console or the dial pad on the desk
console.
Operating Procedure
1. Press an idle loop key.
2. Key in thousands (where applicable) and hundreds digit(s) of...

Page 86

NEAX2400 IMX Business Features and Specifications
Page 56NDA-24221, Issue 3
B-2 Busy Lamp Field - Flexible
Interactions
1. CENTRALIZED ATTENDANT SERVICE (CAS) [C-20]: At the CAS main location, when the
ATTENDANT CONSOLE [A-3] is handling a call from a CAS branch over a Release Line Trunk (RLT),
the BLF will give no indication of busy/idle status of branch location stations.
2. The BLF indicates the station status after the hundreds digit is keyed in by the Attendant.
3. A 2-digit display indicator is...

Page 87

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 57
Busy Verification B-3
B-3 Busy Verification
General Description
When an Attendant places a call to a busy station, this feature allows the Attendant to break into the connection.
When this feature is initiated from the console, the system sends a Warning Tone to the stations before establishing
a three-party conference. Additionally, the Attendant Monitor Function can be activated depending on system data.
Operating Procedure
To...

Page 88

NEAX2400 IMX Business Features and Specifications
Page 58NDA-24221, Issue 3
B-3 Busy Verification
Service Conditions (cont’d)
THREE-WAY CALLING  [T-2, T-2D]
VOICE CALL - Dterm[V-2D]
f.) Modem pooling connection
g.) Data Call through Data Adapter
h.) Data Call through Data Module
i.) The calling station is connected to an Attendant Loop
Note:In each of the above instances, the Attendant will receive reorder tone.
3. Before the Attendant is added to an existing connection, a two-burst tone is applied to...

Page 89

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 59
Busy Verification B-3
Service Conditions (cont’d)
15. UNIFORM CALL DISTRIBUTION (UCD) [U-1]: The Attendant can busy-verify a station line that is
part of a UCD group. That is, the BUSY VERIFICATION call will not hunt. If BUSY VERIFICATION
is attempted on the group number, UCD hunting will take precedence over BUSY VERIFICATION.
16. It is determined in system data to allow monitoring of the busy connection before establishing a...

Page 90

NEAX2400 IMX Business Features and Specifications
Page 60NDA-24221, Issue 3
B-3 Busy Verification
Interactions (cont’d)
8. CALL WAITING [C-12, 31]: If an Attendant attempts to busy-verify a station line that already has a
Waiting call, BUSY VERIFICATION will be denied. Also, if the Attendant attempts to busy-verify a
station line that is waiting for another line, the BUSY VERIFICATION attempt will be temporarily denied
because such waiting calls always involve either a connection to the Attendant...