Page 51
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 21 Attendant Night Transfer A-19 A-19 Attendant Night Transfer General Description When the ATTENDANT CONSOLE [A-3] is in night mode, any operator calls (dial 0 calls) are automatically routed to a predetermined night station. Operating Procedure To answer night call: 1. The user dials the operator call code; receives ringback tone. 2. An operator call is automatically transferred to the night answer station. 3. The calling party...
Page 52
NEAX2400 IMX Business Features and Specifications Page 22NDA-24221, Issue 3 A-19 Attendant Night Transfer Service Conditions (cont’d) 13. Operator calls after Consultation Hold is not transferred to the Night Station. 14. Individual Attendant calls are not transferred to the Night Station assigned by ATTENDANT NIGHT TRANSFER. 15. The Night Station can set CALL FORWARDING - ALL CALLS - OUTSIDE [C-28], CALL FORWARDING - BUSY LINE - OUTSIDE [C-60], and CALL FORWARDING - DONT ANSWER - OUTSIDE [C-74]. 16....
Page 53
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 23 Authorization Code A-20 A-20 Authorization Code General Description An AUTHORIZATION CODE is a numerical code dialed by users (up to 10 digits), which will override the station CLASS OF SERVICE - INDIVIDUAL [C-15] for facility access restriction. The AUTHORIZATION CODE can be masked on the D term display if necessary using the AUTHORIZATION CODE DISPLAY ELIMINATION [A-99]. When a wrong code is received from a station/trunk,...
Page 54
NEAX2400 IMX Business Features and Specifications Page 24NDA-24221, Issue 3 A-20 Authorization Code Service Conditions 1. A maximum of 10 digits for AUTHORIZATION CODE can be dialed, and 8 digits will be registered on STATION MESSAGE DETAIL RECORDING [S-10]. 2. The maximum number of AUTHORIZATION CODES is 4,000. This number is dependent upon system configuration. These specifications are based on the digits being assigned as follows: 1st digit: A (when A equals a unique digit from 0 - 9) 2nd digit: B -...
Page 55
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 25 Authorization Code A-20 Interactions (cont’d) 5. There are no restrictions regarding the first digit of AUTHORIZATION CODES, except what is programmed in AMND. Tenant 0 does not conflict with the PBX numbering plan. This is true when separate tenant tables are provided. If common tenant tables are used, a conflict between LCR(S) and OGC(A), used with SMDR, will occur. Note:The access code to the service feature AUTHORIZATION...
Page 56
NEAX2400 IMX Business Features and Specifications Page 26NDA-24221, Issue 3 A-21 Automatic Trunk Test A-21 Automatic Trunk Test General Description The AUTOMATIC TRUNK TEST capability provides a functional test on a large number of trunks at a prearranged time. The results of the test are reported at the MAINTENANCE ADMINISTRATION TERMINAL (MAT) [M- 18]. The test can include: Ringback Tone Test, 1 KHz Test Tone and Trunk Selection Test, by having the proper test trunk termination at the distant office....
Page 57
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 27 Authorization Code - Tie Line Incoming Routes A-29 A-29 Authorization Code - Tie Line Incoming Routes General Description This service feature offers an outside party the ability to enter an AUTHORIZATION CODE [A- 20] through an incoming TIE Line trunk. Operating Procedure When the incoming route is restricted or when an AUTHORIZATION CODE [A-20] is always required: 1. The called number, office code, and terminal number are...
Page 58
NEAX2400 IMX Business Features and Specifications Page 28NDA-24221, Issue 3 A-29 Authorization Code - Tie Line Incoming Routes Interactions (cont’d) 6. If ASPA, SRV: LCR (Least Cost Route Selection) / LCRS (Register Sender LCR) AH parameter is assigned as data “1”, the request for an AUTHORIZATION CODE is determined by the ARSC assignment of the station in relationship to the route chosen. For AUTHORIZATION CODE - TIE LINE INCOMING ROUTES, no RSC is assigned against the incoming TIE Line, therefore,...
Page 59
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 29 Automatic/Manual Intercom A-30 A-30 Automatic/Manual Intercom General Description This feature permits multiple Dterm users to simultaneously call all the stations in a preassigned group, regardless of their idle/busy status. An INTERCOM member can optionally override another INTERCOM station in a two-party INTERCOM connection. This service is referred to as INTERCOM BRIDGE. INTERCOM service is separated into two types,...
Page 60
NEAX2400 IMX Business Features and Specifications Page 30NDA-24221, Issue 3 A-30 Automatic/Manual Intercom Operating Procedure (cont’d) To bridge into a Manual INTERCOM call: 1. When two stations are engaged in an INTERCOM call, a third station, belonging to the same INTERCOM group, will press the MICM key and go off-hook. 2. A three-party conference is established. The called stations may hear a Warning Tone when the station bridges into the call. This Warning Tone is preassigned in System Data. Use...