Page 361
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 331 Meet-Me Paging - Attendant M-11 Service Conditions (cont’d) 10. Loop signaling is the recommended signaling type. a.) Both MEET-ME PAGING and PAGING ACCESS [P-1] (loudspeaker - basic) can be provided in the same system. b.) A separate access code for MEET-ME PAGING and PAGING ACCESS [P-1] is required for the same paging zone. c.) A paging answer code is required for each MEET-ME PAGING zone. d.) The maximum number of answer...
Page 362
NEAX2400 IMX Business Features and Specifications Page 332NDA-24221, Issue 3 M-11 Meet-Me Paging - Attendant Interactions (cont’d) 2. MEET-ME PAGING is limited to stations and Attendant Consoles. CO trunks, TIE LINE ACCESS [T-6] or REMOTE ACCESS TO PBX SYSTEM [R-2] calls must have the Attendant or user perform the Paging operation. 3. The Attendant Console cannot dial the MEET-ME PAGING answer codes. 4. BUSY VERIFICATION [B-3] and EXECUTIVE OVERRIDE [E-1]: These features will be denied for a connection,...
Page 363
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 333 Maintenance Printout M-15 M-15 Maintenance Printout General Description The NEAX2400 IMX can provide a hard copy of maintenance and system management data via the MAINTENANCE ADMINISTRATION TERMINAL (MAT) [M-18] printer. Operating Procedure Refer to the NEAX2400 IMX Office Data Specification. Service Conditions The following hard copy reports can be obtained: 1. History printout for command execution: When the command is...
Page 364
NEAX2400 IMX Business Features and Specifications Page 334NDA-24221, Issue 3 M-18 Maintenance Administration Terminal (MAT) M-18 Maintenance Administration Terminal (MAT) General Description This feature provides a man-machine interface, using a personal computer, to accomplish such items as on-line system programming of station and trunk data, traffic information, fault condition analysis, and testing of operating programs. Operating Procedure Refer to the NEAX2400 IMX Office Data Specification. Service...
Page 365
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 335 Maintenance Administration Terminal (MAT) M-18 Service Conditions (cont’d) b.) The maximum digits of the USER NAME is 16, and those of the ID CODE is 8. c.) Lock Out information is output with the information of the USER NAME, date, time, and IOC port used as System Message. d.) A maximum of 128 System Messages can be stored. However, if other failure messages are output, the stored number for Audit Trail to Track the Mat Usage...
Page 366
NEAX2400 IMX Business Features and Specifications Page 336NDA-24221, Issue 3 M-19 Message Reminder M-19 Message Reminder General Description This feature allows a single-line telephone to leave a MESSAGE REMINDER at the called Dterm set. Operating Procedure To send a message from a single-line telephone: 1. Dial the desired internal Dterm station; receive ringback tone or busy tone. 2. Press switch hook; receive special dial tone. 3. Dial the MESSAGE REMINDER access code; receive service set tone. 4....
Page 367
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 337 Message Reminder M-19 Service Conditions (cont’d) 12. A maximum of 32 digits can be saved at the called party. 13. To memorize the telephone number of the calling station, assign SYS1, index 641, b0=1 by the ASYDN command.
Page 368
NEAX2400 IMX Business Features and Specifications Page 338NDA-24221, Issue 3 M-19D Message Reminder - Dterm M-19D Message Reminder - Dterm General Description This feature allows a Dterm to leave a MESSAGE REMINDER at another Dterm. Operating Procedure To send a message from a Dterm: 1. Dial the desired Dterm station, receive ringback tone or busy tone. 2. Press the MSG key; the LCD displays: Service set tone is heard. 3. At the called D term, the MSG LED will light to indicate a message has been set....
Page 369
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 339 Message Reminder - DtermM-19D Service Conditions (cont’d) 5. Messages can be displayed only when the station is on-hook. A message may be cleared by displaying the message and pressing the “*” or “#” key on the called Dterms key pad. 6. A message is cleared when it is obtained via the MSG key. 7. Messages cannot be cleared by the message sender. 8. A second message sent by the same calling D term is registered as a second...
Page 370
NEAX2400 IMX Business Features and Specifications Page 340NDA-24221, Issue 3 M-20D Multiple Line Operation - Dterm M-20D Multiple Line Operation - Dterm General Description This feature allows for the appearance of multiple lines on the programmable line/feature keys of the Dterm set. Operating Procedure No manual operation is required. Service Conditions 1. Three kinds of lines can appear on Dterms: MY Line (ML): This line is associated with the extension number assigned to the port on the interface...