Page 51
NEAX2000 IVS2 OAI System ManualPage 44 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for TMF DESCRIPTION DATA Specify a chime from Dterm when receiving RR signal of TMF. (1) (2)Y=7 F1032-F1047: OAI Function Key No. 0-15 00 : Not sent 01 : To send Specify a chime from D term when setting up TMF. (1) (2)Y=8 00: Chime before sending terminal messages (when pressing the OAI Function key) 02: Chime after sending terminal messages 00 : No ring 01 : Ring Specify the...
Page 52
CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for SCF NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 45 DATA ASSIGNMENT FOR SCF To provide Call Origination with Ringing (FID=3): To originate a call with Account Code (FID=1, 3, 4, 7): DESCRIPTION DATA Assign the Ringing Tone Sending time for SCF of OAI. (1) (2)Y=0 65: OAI RGT Sending Time 01-99: 4-396 sec. (4 sec. increments) If no data is set, the default setting is 12-16 sec. DESCRIPTION DATA Specify the maximum number of...
Page 53
NEAX2000 IVS2 OAI System ManualPage 46 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for SCF If the Digital Announcement Trunk or Tone is provided, do the following programming: DESCRIPTION DATA Assign a Digital Announcement Trunk card number to the required LEN. NOTE 1:The Digital Announcement Trunk card number must be assigned to the first LEN (Level 0), the third LEN (Level 2), the fifth LEN (Level 4) and the seven LEN (Level 6) of each LT slot. NOTE 2:EB000 and...
Page 54
CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for SCF NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 47 To provide Queue Connection (FID=4): To provide the system with a monitor number: DESCRIPTION DATA Assign the UCD group. (1) (2)Y=0 X-XXXX: Station No. X-XXXX: Another station No. to be linked Assign the Pilot station and Member station to queuing for SCF of OAI. (1) (2)Y=1 Distinction of Member station from Pilot station X-XXXX: Station No. 2: Off Hook suppressed 3:...
Page 55
NEAX2000 IVS2 OAI System ManualPage 48 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for SCF To provide Announcement Call (FID=5): DESCRIPTION DATA Assign a Digital Announcement Trunk card number to the required LEN. NOTE 1:The Digital Announcement Trunk card number must be assigned to the first LEN (Level 0), the third LEN (Level 2), the fifth LEN (Level 4) and the seven LEN (Level 6) of each LT slot. NOTE 2:EB000 and EB001 are dedicated to built-in Digital...
Page 56
CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for SCF NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 49 DESCRIPTION DATA Assign the function of the Digital Announcement Trunk card. (1) (2)YY=00 000-001: Built-in DAT on MP card 002-127: Digital Announcement Trunk Card No. assigned by CM10 (EB002-EB127) 10: Announcement Service for OAI 16 XX XX: Message Group No. (02-63) for Multi-Connection Announcement Service for OAI. Assign the Digital Announcement Trunk card number. (1)...
Page 57
NEAX2000 IVS2 OAI System ManualPage 50 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for SCF To provide Conversation Monitoring (FID=6) and Call Conferencing (FID=8): DESCRIPTION DATA Assign the Ringing Tone Sending time for SCF of OAI. (1) (2)Y=0 65: OAI RGT Sending Time 01-99: 4-396 sec. (4 sec. increments) If no data is set, the default setting is 12-16 sec. START CM41 END
Page 58
CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for FLF NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 51 DATA ASSIGNMENT FOR FLF DESCRIPTION DATA Assign the access code to recognize Authorization Code for FLF. NOTE:The access code should be as- signed to the first one, two or three digits of Authorization Code. For example: (1) (2)Y=0-3 X-XXXX: Access Code A157 Assign the maximum number of digits for Authorization Code.(1) (2)11 01-10 : Max. Number of Digits START CM20...
Page 59
NEAX2000 IVS2 OAI System ManualPage 52 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for FLF DESCRIPTION DATA Assign the recognition of AP database by RR message. (1) (2)Y=A 00 0 : To provide 1 : Not provided Assign the omission of AP database for information added to RR message. (1) (2)Y=A 01 0 : Not omitted 1 : To omit Assign the office number. (1) (2)Y=5 00 Office No. (Max. 4 digits) Assign the processor for Authorization Code/Forced Account Code.(1) (2)216 1...
Page 60
CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for KTF NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 53 DATA ASSIGNMENT FOR KTF DESCRIPTION DATA Assign the OAI function key for starting up FLF to a D term. (1) (2)YY=00 My Line No. + + Key No. F1032-F1047: OAI Function Key No. 0-15 START CM90 END ,