 NEAX2000 IVS2 OAI System ManualPage 44  ND-70922 (E), Issue 1.0
CHAPTER 3  SYSTEM DATA PROGRAMMING
Data Assignment for TMF
DESCRIPTION DATA
Specify a chime from Dterm when 
receiving RR signal of TMF.
(1)
(2)Y=7
F1032-F1047: OAI Function Key
No. 0-15
00  : Not sent
01  : To send
Specify a chime from D
term when setting 
up TMF.
(1)
(2)Y=8 
00: Chime before sending terminal
messages (when pressing the OAI
Function key) 
02: Chime after sending terminal
messages
00  : No ring
01  : Ring
Specify the...

Page 52

CHAPTER 3  SYSTEM DATA PROGRAMMING
Data Assignment for SCF
NEAX2000 IVS2 OAI System Manual    
ND-70922 (E), Issue 1.0   Page 45
DATA ASSIGNMENT FOR SCF
To provide Call Origination with Ringing (FID=3):
To originate a call with Account Code (FID=1, 3, 4, 7):
DESCRIPTION DATA
Assign the Ringing Tone Sending time for 
SCF of OAI.
(1)
(2)Y=0
65: OAI RGT Sending Time 
01-99: 4-396 sec. (4 sec. increments)
If no data is set, the default setting is 12-16 
sec.
DESCRIPTION DATA
Specify the maximum number of...

Page 53

 NEAX2000 IVS2 OAI System ManualPage 46  ND-70922 (E), Issue 1.0
CHAPTER 3  SYSTEM DATA PROGRAMMING
Data Assignment for SCF
If the Digital Announcement Trunk or Tone is provided, do the following programming:
DESCRIPTION DATA
Assign a Digital Announcement Trunk card 
number to the required LEN.
NOTE 1:The Digital Announcement Trunk 
card number must be assigned to 
the first LEN (Level 0), the third 
LEN (Level 2), the fifth LEN 
(Level 4) and the seven LEN 
(Level 6) of each LT slot.
NOTE 2:EB000 and...

Page 54

CHAPTER 3  SYSTEM DATA PROGRAMMING
Data Assignment for SCF
NEAX2000 IVS2 OAI System Manual    
ND-70922 (E), Issue 1.0   Page 47
To provide Queue Connection (FID=4):
To provide the system with a monitor number:
DESCRIPTION DATA
Assign the UCD group. 
(1)
(2)Y=0
X-XXXX: Station No.
X-XXXX: Another station No. to be
linked
Assign the Pilot station and Member 
station to queuing for SCF of OAI.
(1)
(2)Y=1 Distinction of Member station from 
Pilot station 
X-XXXX: Station No. 
2: Off Hook suppressed
3:...

Page 55

 NEAX2000 IVS2 OAI System ManualPage 48  ND-70922 (E), Issue 1.0
CHAPTER 3  SYSTEM DATA PROGRAMMING
Data Assignment for SCF
To provide Announcement Call (FID=5):
DESCRIPTION DATA
Assign a Digital Announcement Trunk card 
number to the required LEN.
NOTE 1:The Digital Announcement Trunk 
card number must be assigned 
to the first LEN (Level 0), the 
third LEN (Level 2), the fifth LEN 
(Level 4) and the seven LEN 
(Level 6) of each LT slot.
NOTE 2:EB000 and EB001 are dedicated 
to built-in Digital...

Page 56

CHAPTER 3  SYSTEM DATA PROGRAMMING
Data Assignment for SCF
NEAX2000 IVS2 OAI System Manual    
ND-70922 (E), Issue 1.0   Page 49
DESCRIPTION DATA
Assign the function of the Digital 
Announcement Trunk card.
(1)
(2)YY=00
000-001: Built-in DAT on MP card
002-127: Digital Announcement Trunk
Card No. assigned by CM10
(EB002-EB127)
10: Announcement Service for OAI 
16 XX
XX: Message Group No. (02-63) for
Multi-Connection Announcement
Service for OAI.
Assign the Digital Announcement Trunk 
card number.
(1)...

Page 57

 NEAX2000 IVS2 OAI System ManualPage 50  ND-70922 (E), Issue 1.0
CHAPTER 3  SYSTEM DATA PROGRAMMING
Data Assignment for SCF
To provide Conversation Monitoring (FID=6) and Call Conferencing (FID=8):
DESCRIPTION DATA
Assign the Ringing Tone Sending time for 
SCF of OAI.
(1)
(2)Y=0 
65: OAI RGT Sending Time
01-99: 4-396 sec. (4 sec. increments)
If no data is set, the default setting is 12-16 
sec.
START
CM41
END 

Page 58

CHAPTER 3  SYSTEM DATA PROGRAMMING
Data Assignment for FLF
NEAX2000 IVS2 OAI System Manual    
ND-70922 (E), Issue 1.0   Page 51
DATA ASSIGNMENT FOR FLF
DESCRIPTION DATA
Assign the access code to recognize 
Authorization Code for FLF.
NOTE:The access code should be as-
signed to the first one, two or 
three digits of Authorization 
Code. For example:
(1)
(2)Y=0-3
X-XXXX: Access Code
A157
Assign the maximum number of digits for 
Authorization Code.(1)
(2)11 
01-10  : Max. Number of Digits
START
CM20...

Page 59

 NEAX2000 IVS2 OAI System ManualPage 52  ND-70922 (E), Issue 1.0
CHAPTER 3  SYSTEM DATA PROGRAMMING
Data Assignment for FLF
DESCRIPTION DATA
Assign the recognition of AP database by 
RR message.
(1)
(2)Y=A
00
0  : To provide
1  : Not provided
Assign the omission of AP database for 
information added to RR message.
(1)
(2)Y=A
01
0  : Not omitted
1  : To omit
Assign the office number. 
(1)
(2)Y=5
00
Office No. (Max. 4 digits)
Assign the processor for Authorization 
Code/Forced Account Code.(1)
(2)216
1...

Page 60

CHAPTER 3  SYSTEM DATA PROGRAMMING
Data Assignment for KTF
NEAX2000 IVS2 OAI System Manual    
ND-70922 (E), Issue 1.0   Page 53
DATA ASSIGNMENT FOR KTF
DESCRIPTION DATA
Assign the OAI function key for starting up 
FLF to a D
term.
(1)
(2)YY=00
My Line No. +   + Key No.
F1032-F1047: OAI Function Key No. 
0-15
START
CM90
END
, 