 NEAX2000 IVS2 OAI System ManualPage 14  ND-70922 (E), Issue 1.0
CHAPTER 2  INSTALLATION
Precautions
Caution
You must hold the edge of a circuit card when plugging or unplugging the circuit card. If you 
touch another area, you may be exposed to hazardous voltages.
CARD FRONT
NEVER TOUCH THE 
COMPONENTS OR SOLDERED 
SURFACE WITH BARE HANDS.
PBX 

Page 22

CHAPTER 2  INSTALLATION
Required Equipment
NEAX2000 IVS2 OAI System Manual    
ND-70922 (E), Issue 1.0   Page 15
REQUIRED EQUIPMENT
Table 2-1 and Table 2-2 show the required equipment when the OAI is provided through an
external processor with RS-232C interface, or through the Ethernet with TCP/IP.
Required Equipment for OAI with RS-232C Interface
Table 2-1  Required Equipment for OAI with RS-232C Interface
EQUIPMENT DESCRIPTION QTY REMARKS
 PN-AP01 OAI Interface Card 1
 RS NORM-4 CA-A
/RS NORM-4S...

Page 23

 NEAX2000 IVS2 OAI System ManualPage 16  ND-70922 (E), Issue 1.0
CHAPTER 2  INSTALLATION
Required Equipment
Required Equipment for OAI with TCP/IP-Ethernet
Table 2-2  Required Equipment for OAI with TCP/IP-Ethernet
EQUIPMENT DESCRIPTION QTY REMARKS
 PN-AP01 OAI Interface Card 1
 PN-CC01 Ethernet Control Card 1
 48-TW-0.3 CONN CA BUS Cable between PN-
AP01 and PN-CC011 Cable length: 
0.3 m/1 ft.
 10 BASE-T twisted 
pair cable (TIA/EIA 
category 3 or larger)10 BASE-T Cable between 
PN-CC01 and...

Page 24

CHAPTER 2  INSTALLATION
Installation Procedure
NEAX2000 IVS2 OAI System Manual    
ND-70922 (E), Issue 1.0   Page 17
INSTALLATION PROCEDURE
Installation Procedure for OAI with RS-232C
Install the OAI system with RS-232C interface according to the following procedure.
Figure 2-2  Installation Procedure for OAI with RS-232C Interface
Installation Procedure for OAI with TCP/IP-Ethernet
Install the OAI system with TCP/IP-Ethernet according to the following procedure.
Figure 2-3  Installation Procedure for...

Page 25

 NEAX2000 IVS2 OAI System ManualPage 18  ND-70922 (E), Issue 1.0
CHAPTER 2  INSTALLATION
Installation Procedure
Mounting PN-AP01 Card
(1) Confirm the correct switch settings. See CHAPTER 5.Page 65
Before mounting the card, set the MB switch to UP position.
(2) Mount the PN-AP01 card in one of the following AP slots.
PIM 0 : AP00-AP10 slot
PIM 1-7: AP00-AP11 slot
After mounting the card, set the MB switch to DOWN position.Contents
Static Sensitive:
Precautions Required HandlingATTENTION 

Page 26

CHAPTER 2  INSTALLATION
Installation Procedure
NEAX2000 IVS2 OAI System Manual    
ND-70922 (E), Issue 1.0   Page 19
Mounting PN-CC01 Card
(1) Confirm the correct switch settings. See CHAPTER 5. Page 65
(2) Mount the PN-CC01 card in one of the following AP slots.
PIM 0 : AP00-AP10 slot
PIM 1-7: AP00-AP11 slotContents
Static Sensitive:
Precautions Required HandlingATTENTION 

Page 27

 NEAX2000 IVS2 OAI System ManualPage 20  ND-70922 (E), Issue 1.0
CHAPTER 2  INSTALLATION
Installation Procedure
Mounting PN-CP15 Card
(1) Confirm the correct switch settings. See CHAPTER 5. Page 65
Before mounting the card, set the MB switch to UP position.
(2) Mount one PN-CP15 card in the each FP slot of PIM0, PIM2, PIM4 and 
PIM6, according to the system configuration.
After mounting the card, set the MB switch to DOWN position.Contents
Static Sensitive:
Precautions Required HandlingATTENTION 

Page 28

CHAPTER 2  INSTALLATION
Installation Procedure
NEAX2000 IVS2 OAI System Manual    
ND-70922 (E), Issue 1.0   Page 21
Cabling between PN-AP01 Card and External Processor
(1) Connect the RS RVS cable or RS NORM cable onto the “RS0” connector on the PN-AP01 
card, as shown in Figure 2-4.
Figure 2-4  Cable Running of RS RVS Cable/RS NORM Cable
PN-AP01
RS RVS-4(S) CA-A/RS RVS-4(S) CA-C
TO EXTERNAL IP
PROCESSOR/MODEM RS RVS-15(S) CA-A/RS NORM-4 CA-A/RS NORM-4S CA-A
RS0 

Page 29

 NEAX2000 IVS2 OAI System ManualPage 22  ND-70922 (E), Issue 1.0
CHAPTER 2  INSTALLATION
Installation Procedure
(2) Connect the RS RVS cable or RS NORM cable, as shown in Figure 2-5 and Figure 2-6.
When connecting an External Processor directly:
Connect the External Processor to the PN-AP01 using an RS RVS-4(S) CA-A/RS RVS-4(S) 
CA-C/RS RVS-15(S) CA-A cable, as shown in Figure 2-5.
Figure 2-5  Direct Connection
When connecting an External Processor using MODEMs: 
Connect the External Processor through...

Page 30

CHAPTER 2  INSTALLATION
Installation Procedure
NEAX2000 IVS2 OAI System Manual    
ND-70922 (E), Issue 1.0   Page 23
Cabling BUS Cable and 10 BASE-T Cable
(1) Connect the 48-TW-0.3 CONN CA (BUS cable) onto the “IP” connector on the PN-CC01 
card, as shown in Figure 2-7.
(2) Connect the 10 BASE-T twisted pair cable (TIA/EIA Category 3 or larger) onto the “10 
BASE-T” connector on the PN-CC01 card, as shown in Figure 2-7.
Figure 2-7  Cable Connections on PN-CC01 Card
TO PN-AP01
48-TW-0.3 CONN CA
IP...