    							 NEAX2000 IVS2 OAI System ManualPage 14  ND-70922 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Precautions
    Caution
    You must hold the edge of a circuit card when plugging or unplugging the circuit card. If you 
    touch another area, you may be exposed to hazardous voltages.
    CARD FRONT
    NEVER TOUCH THE 
    COMPONENTS OR SOLDERED 
    SURFACE WITH BARE HANDS.
    PBX 
    						
    							CHAPTER 2  INSTALLATION
    Required Equipment
    NEAX2000 IVS2 OAI System Manual    
    ND-70922 (E), Issue 1.0   Page 15
    REQUIRED EQUIPMENT
    Table 2-1 and Table 2-2 show the required equipment when the OAI is provided through an
    external processor with RS-232C interface, or through the Ethernet with TCP/IP.
    Required Equipment for OAI with RS-232C Interface
    Table 2-1  Required Equipment for OAI with RS-232C Interface
    EQUIPMENT DESCRIPTION QTY REMARKS
     PN-AP01 OAI Interface Card 1
     RS NORM-4 CA-A
    /RS NORM-4S CA-AConnecting Cable between 
    PN-AP01 and MODEM 
    (Required if 15 m/49 ft. or 
    more)1 Cable length: 4 m/13 ft.
     RS RVS-4 CA-A
    /RS RVS-4S CA-A
    /RS RVS-4 CA-C
    /RS RVS-4S CA-CConnecting Cable between 
    PN-AP01 and External 
    Processor1 Cable length: 4 m/13 ft.
    or
     RS RVS-15 CA-A
    /RS RVS-15S CA-A1 Cable length: 15 m/49 ft.
     RS-232C Cable Connecting Cable between 
    External Processor and 
    MODEM1 Required if 15 m/49 ft. or 
    more is needed
    (Should be provided by 
    customer)
     External Processor 
    with RS-232C Interface1 (Should be provided by 
    customer)
     MODEM Refer to MODEM 
    Specification. Page 92 Required if 15 m/49 ft. or 
    more is needed
    (Should be provided by 
    customer) 
    						
    							 NEAX2000 IVS2 OAI System ManualPage 16  ND-70922 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Required Equipment
    Required Equipment for OAI with TCP/IP-Ethernet
    Table 2-2  Required Equipment for OAI with TCP/IP-Ethernet
    EQUIPMENT DESCRIPTION QTY REMARKS
     PN-AP01 OAI Interface Card 1
     PN-CC01 Ethernet Control Card 1
     48-TW-0.3 CONN CA BUS Cable between PN-
    AP01 and PN-CC011 Cable length: 
    0.3 m/1 ft.
     10 BASE-T twisted 
    pair cable (TIA/EIA 
    category 3 or larger)10 BASE-T Cable between 
    PN-CC01 and Ethernet1 Cable length: 
    Max. 100 m/328 ft.
    (Should be provided by 
    customer)
    NOTE 
    						
    							CHAPTER 2  INSTALLATION
    Installation Procedure
    NEAX2000 IVS2 OAI System Manual    
    ND-70922 (E), Issue 1.0   Page 17
    INSTALLATION PROCEDURE
    Installation Procedure for OAI with RS-232C
    Install the OAI system with RS-232C interface according to the following procedure.
    Figure 2-2  Installation Procedure for OAI with RS-232C Interface
    Installation Procedure for OAI with TCP/IP-Ethernet
    Install the OAI system with TCP/IP-Ethernet according to the following procedure.
    Figure 2-3  Installation Procedure for OAI with TCP/IP-Ethernet
    Mounting PN-CP15 Card
    Mounting PN-AP01 Card
    Cabling Between PN-AP01
    Card and External Processor
    END
    START
     Page 18
     Page 20
     Page 21
    END
    START
    Cabling BUS Cable and
    10 BASE-T Cable
    Mounting PN-CC01 Card 
    Mounting PN-AP01 Card
    Mounting PN-CP15 Card
     Page 18
     Page 19
     Page 20
     Page 23 
    						
    							 NEAX2000 IVS2 OAI System ManualPage 18  ND-70922 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation Procedure
    Mounting PN-AP01 Card
    (1) Confirm the correct switch settings. See CHAPTER 5.Page 65
    Before mounting the card, set the MB switch to UP position.
    (2) Mount the PN-AP01 card in one of the following AP slots.
    PIM 0 : AP00-AP10 slot
    PIM 1-7: AP00-AP11 slot
    After mounting the card, set the MB switch to DOWN position.Contents
    Static Sensitive:
    Precautions Required HandlingATTENTION 
    						
    							CHAPTER 2  INSTALLATION
    Installation Procedure
    NEAX2000 IVS2 OAI System Manual    
    ND-70922 (E), Issue 1.0   Page 19
    Mounting PN-CC01 Card
    (1) Confirm the correct switch settings. See CHAPTER 5. Page 65
    (2) Mount the PN-CC01 card in one of the following AP slots.
    PIM 0 : AP00-AP10 slot
    PIM 1-7: AP00-AP11 slotContents
    Static Sensitive:
    Precautions Required HandlingATTENTION 
    						
    							 NEAX2000 IVS2 OAI System ManualPage 20  ND-70922 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation Procedure
    Mounting PN-CP15 Card
    (1) Confirm the correct switch settings. See CHAPTER 5. Page 65
    Before mounting the card, set the MB switch to UP position.
    (2) Mount one PN-CP15 card in the each FP slot of PIM0, PIM2, PIM4 and 
    PIM6, according to the system configuration.
    After mounting the card, set the MB switch to DOWN position.Contents
    Static Sensitive:
    Precautions Required HandlingATTENTION 
    						
    							CHAPTER 2  INSTALLATION
    Installation Procedure
    NEAX2000 IVS2 OAI System Manual    
    ND-70922 (E), Issue 1.0   Page 21
    Cabling between PN-AP01 Card and External Processor
    (1) Connect the RS RVS cable or RS NORM cable onto the “RS0” connector on the PN-AP01 
    card, as shown in Figure 2-4.
    Figure 2-4  Cable Running of RS RVS Cable/RS NORM Cable
    PN-AP01
    RS RVS-4(S) CA-A/RS RVS-4(S) CA-C
    TO EXTERNAL IP
    PROCESSOR/MODEM RS RVS-15(S) CA-A/RS NORM-4 CA-A/RS NORM-4S CA-A
    RS0 
    						
    							 NEAX2000 IVS2 OAI System ManualPage 22  ND-70922 (E), Issue 1.0
    CHAPTER 2  INSTALLATION
    Installation Procedure
    (2) Connect the RS RVS cable or RS NORM cable, as shown in Figure 2-5 and Figure 2-6.
    When connecting an External Processor directly:
    Connect the External Processor to the PN-AP01 using an RS RVS-4(S) CA-A/RS RVS-4(S) 
    CA-C/RS RVS-15(S) CA-A cable, as shown in Figure 2-5.
    Figure 2-5  Direct Connection
    When connecting an External Processor using MODEMs: 
    Connect the External Processor through the MODEMs, as shown in Figure 2-6. In this case, 
    the RS NORM-4 CA-A/RS NORM-4S CA-A should be used for DCE-DCE connection.
    When the cable length between the External Processor and PBX is more than 15 m/49 ft., 
    MODEMs are required.
    Figure 2-6  MODEM Connection
    PBX
    (PIM0-PIM7)
    PN-
    AP01RS0
    RS RVS-4(S) CA-A/RS RVS-4(S) CA-C (4 m/13.1 ft.)
    External
    Processor
    (RS-232C) RS RVS-15(S) CA-A (15 m/49 ft.)
    External
    Processor
    (RS-232C) MODEM MODEM
    RS NORM-4 CA-A/RS NORM-4S CA-A (4 m /13 ft.) PN-
    AP01RS0 PBX
    (PIM0-PIM7)
    2P 
    						
    							CHAPTER 2  INSTALLATION
    Installation Procedure
    NEAX2000 IVS2 OAI System Manual    
    ND-70922 (E), Issue 1.0   Page 23
    Cabling BUS Cable and 10 BASE-T Cable
    (1) Connect the 48-TW-0.3 CONN CA (BUS cable) onto the “IP” connector on the PN-CC01 
    card, as shown in Figure 2-7.
    (2) Connect the 10 BASE-T twisted pair cable (TIA/EIA Category 3 or larger) onto the “10 
    BASE-T” connector on the PN-CC01 card, as shown in Figure 2-7.
    Figure 2-7  Cable Connections on PN-CC01 Card
    TO PN-AP01
    48-TW-0.3 CONN CA
    IP
    PN-CC01
    10 BASE-TTO 10 BASE-T HUB
    10 BASE-T TWISTED PAIR CABLE(TIA/EIA CATEGORY 3 OR LARGER) 
    						