NEAX2000 IVS2 OAI System ManualPage 54 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for ACF DATA ASSIGNMENT FOR ACF DESCRIPTION DATA Specify the processor to check the ID Codes.(1) (2)217 1 : AP (PN-AP01) Specify whether SST is sent after dialing the access code for ID Code Class Change or not.(1) (2)362 0 : No Tone 1 : Service Set Tone (SST) Assign the number of digits for each ID code of Authorization Code/Forced Account Code/Remote Access to System (DISA).(1) (2)11: Authorization Code 12: Forced Account Code 13: Remote Access to System (DISA) 01-10: Number of digits Assign the Access code for ID Code Class Change. (1) (2)Y=0-3 Numbering Plan Group 0-3 X-XXXX: Access Code A086: Authorization Code A087: Forced Account Code Assign the Temporary Class data to the ID codes. NOTE:This data is to use PBX internal class change data when ACF is in operation and the AP stopped. The number of digits is set through CMD7 Y=B. (1) (2)Y=3 ID code A BB CC DD EE A: Type of Temporary Service Class 0: Unrestricted 1: Fully-Restricted 2: Temporary Service Class 9: Delete of the ID Code BB: 01-08: Trunk Restriction Class CC: 00-15: Service Feature Class-A DD: 00-15: Service Feature Class-B EE: 00-15: Service Feature Class-C CM20 START CM08 A CM42 CMD5
CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for ACF NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 55 DESCRIPTION DATA Assign the return result waiting timer for the PBX sent facility. (1) (2)Y=3 00 000-127: 8-508 sec. (4-sec. increments) If no data is set, the default setting is 8 sec. Assign the office number. (1) (2)Y=5 00 Office No. (Max. 4 digits) Assign the Number of ID code digits when AP stops during ACF operation. (1) (2)Y=B 00 0 : No ACF operation 1 : 1 digit 2 : 2 digits 3 : 3 digits END CMD7 A
NEAX2000 IVS2 OAI System ManualPage 56 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for SSF DATA ASSIGNMENT FOR SSF DESCRIPTION DATA Assign the Message Wait Indication (VM) for My Line only or My Line and sub-line on D term.(1) (2)140 0 : MW for My Line and sub-lines 1 : MW for My Line only Whether Message Waiting/Message Reminder is reset (turning the MW Lamp off) by answering at the called station when the calling station calls again after setting this feature.(1) (2)235 0: Available When a forwarded call is terminated to the VMS via CCIS, Whether Message Waiting from the VMS is provided for the called station.(1) (2)376 0 : To provide 1 : Not provided Assign the Type of Voice Mail System. (1) (2)443 0: VMS with MCI Message Waiting lamp control from VMS with MCI to all stations. NOTE:MW lamp control is only available to the stations in the opposite PBX connected with CCIS via MCI. Station dialing MW access codes are not allowed over CCIS.(1) (2)444 0: Available Assign the Message Waiting/Message Reminder. (1) (2)YY=03 X-XXXX: Station No. 0: To provide (For the station with MW lamp) START CM08 END CM13
CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for SMF NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 57 DATA ASSIGNMENT FOR SMF DESCRIPTION DATA Assign the automatic setting of SMFR for D term Sub line.(1) (2)429 0 : Available 1 : Not available Specify OAI SMFN STS (status) for Call Transfer from a station.(1) (2)460 0 : SMFN STS=7 1 : SMFN STS=0 Specify whether OAI SMFN is sent when answering a held call.(1) (2)461 0 : Sent 1 : Not sent Specify whether ANI/Caller ID/CPN is sent to OAI terminal.(1) (2)462 0 : Available 1 : Not available Assign the OAI-TSAPI/SCF facility. (1) (2)464 0 : Same as IMX system (recommended setting) 1 : SMFN Off-Hook indication sent Assign the SMFN/SSFN delay timer (1) (2)Y=A 02 0 : Immediate start 1 : 512 msec. delay START CM08 END CMD7
NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 59 CHAPTER 4 TROUBLESHOOTING This chapter explains the troubleshooting information after installing the OAI system.
NEAX2000 IVS2 OAI System ManualPage 60 ND-70922 (E), Issue 1.0 CHAPTER 4 TROUBLESHOOTING Troubleshooting for OAI with RS-232C TROUBLESHOOTING FOR OAI WITH RS-232C This section explains the troubleshooting information for the OAI system with RS-232C. Table 4-1 shows the cause of trouble and the remedial action. Table 4-1 Troubleshooting Information for OAI with RS-232C TROUBLE CAUSE ACTION The PN-AP01 does not set up. The AP data (07) of PN-AP01 has not been assigned by CM05. Assign the AP data (07) by CM05, then initialize the PN- AP01 (press SW1 of MP card). The AP data (07) of PN-AP01 has been assigned to two slot numbers. Delete one data of the two, then initialize the PN-AP01 (press SW1 of MP card). The unused data have been assigned by CMA6. Confirm the programming procedure of Chapter 3, then assign the correct data. The system cannot communicate with an external processor at all. The cables between the system and an external processor have not been connected properly. Connect the cables properly. The attribute data for RS-232C port of PN-AP01 have not been assigned by CMA6. When providing OAI with RS- 232C, assign the attribute data in accordance with the external processor attribution. The attribute data assigned by CMA6 have not coincided with the external processor attribution. When providing the OAI with RS-232C, assign the attribute data in accordance with the external terminal attribution. The PN-AP01 has not been initialized after the programming of CMA6. Initialize the PN-AP01 (Move the MB switch on the PN-AP01 up and down). The switches of MODEM have not been set properly. Set the switches properly.
CHAPTER 4 TROUBLESHOOTING Troubleshooting for OAI with RS-232C NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 61 The system cannot communicate with an external processor at all. In an external processor (RS- 232C) connection via MODEM, the RTS signal control of RS-232 port has been effective (CMA6 YY=11, 2nd Data=1). Assign 0 (RTS Signal ON) as the 2nd data of CMA6 YY=11. The OAI function key of D term does not operate. The OAI function key has not been assigned by CM90. Assign the OAI function key to Dterm. The operation code for MSF/TMF has not been assigned by CMD7 Y=0. Assign the operation code. The operation code for MSF/TMF has not been accepted by the external processor. Check the application program of the external processor, then assign correct operation code. Table 4-1 Troubleshooting Information for OAI with RS-232C (Continued) TROUBLE CAUSE ACTION
NEAX2000 IVS2 OAI System ManualPage 62 ND-70922 (E), Issue 1.0 CHAPTER 4 TROUBLESHOOTING Troubleshooting for OAI with TCP/IP-Ethernet TROUBLESHOOTING FOR OAI WITH TCP/IP-ETHERNET This section explains the troubleshooting information for the OAI system with TCP/IP-Ethernet. Table 4-2 shows the cause of trouble and the remedial action. When a trouble occurs, do the remedial action. Troubleshooting Information for ETHER Card The lamp indications on the PN-CC01 card on normal condition are as follows: NOTE:Confirm connection of a cable if a lamp disappears. Table 4-2 Troubleshooting Information for ETHER Card TROUBLE CAUSE ACTION The system cannot communicate with an external processor at all. The cables between the system and an external processor have not been connected properly. Connect the cable properly. The IP Address overlaps with another. Confirm the data set by CMD7 Y=9, and assign the correct data. The MAC Address overlaps with another. Confirm the switch setting on the PN-CC01 card, and set correctly. LAMP NAME COLOR FUNCTION RUN Green Flashes at 60 IPM while this card is operating normally. LINK Green Lights when link is established. NOTE XMT Green Lights when transmitting data. RCV Green Lights when receiving data. RVP Green Lights when receiving data with own IP Address. ERR Not used
CHAPTER 4 TROUBLESHOOTING Troubleshooting for OAI with TCP/IP-Ethernet NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 63 Troubleshooting Information for PN-AP01 Card Table 4-3 Troubleshooting Information for PN-AP01 Card TROUBLE CAUSE ACTION The PN-AP01 does not set up. The AP data (07) of PN-AP01 has not been assigned by CM05. Assign the AP data (07) by CM05, then initialize the PN- AP01 (press SW1 of MP card). The AP data (07) of PN-AP01 has been assigned to two slot numbers. Delete one data of the two, then initialize the PN-AP01 (press SW1 of MP card). The unused data have been assigned by CMA6. Confirm the programming procedure of CHAPTER 3, then assign the correct data.
NEAX2000 IVS2 OAI System ManualPage 64 ND-70922 (E), Issue 1.0 CHAPTER 4 TROUBLESHOOTING Troubleshooting for OAI with TCP/IP-Ethernet Replacement Procedure for PN-AP01/PN-CC01 Card When replacing the PN-AP01 card or the PN-CC01 card with power on, do the following procedure. (1) Procedure for PN-AP01 Card (a) When unplugging: Set the MB switch on the PN-AP01 card to the UP position. Remove the BUS cable (48-TW-0.3 CONN CA). Unplug the PN-AP01 card from the card slot. (b) When plugging in: Set the MB switch on the PN-AP01 card to the UP position. Plug in the PN-AP01 card to the card slot. Connect the BUS cable with the PN-AP01 card. Set the MB switch on the PN-AP01 card to the DOWN position. (2) Procedure for PN-CC01 Card (a) When unplugging: Remove the transceiver cable/10 BASE-T cable. Remove the BUS cable. Set the MB switch on the PN-CC01 to the UP position. Unplug the PN-CC01 card from the card slot. (b) When plugging in: Set the MB switch on the PN-CC01 to the UP position. Plug in the PN-CC01 card to the card slot. Connect the BUS cable with the PN-CC01 card. Connect the 10 BASE-T cable with the PN-CC01 card. Set the MB switch on the PN-CC01 to the DOWN position.