    							 NEAX2000 IVS2 OAI System ManualPage 54  ND-70922 (E), Issue 1.0
    CHAPTER 3  SYSTEM DATA PROGRAMMING
    Data Assignment for ACF
    DATA ASSIGNMENT FOR ACF
    DESCRIPTION DATA
    Specify the processor to check the ID 
    Codes.(1)
    (2)217
    1  : AP (PN-AP01)
    Specify whether SST is sent after dialing 
    the access code for ID Code Class 
    Change or not.(1)
    (2)362
    0  : No Tone
    1  : Service Set Tone (SST)
    Assign the number of digits for each ID 
    code of Authorization Code/Forced 
    Account Code/Remote Access to System 
    (DISA).(1)
    (2)11: Authorization Code
    12: Forced Account Code
    13: Remote Access to System (DISA)
    01-10: Number of digits
    Assign the Access code for ID Code 
    Class Change.
    (1)
    (2)Y=0-3 Numbering Plan Group 0-3
    X-XXXX: Access Code
    A086: Authorization Code
    A087: Forced Account Code
    Assign the Temporary Class data to the 
    ID codes.
    NOTE:This data is to use PBX internal 
    class change data when ACF is 
    in operation and the AP stopped.
    The number of digits is set 
    through CMD7 Y=B.
    (1)
    (2)Y=3 
    ID code
    A BB CC DD EE
    A: Type of Temporary Service Class
    0: Unrestricted
    1: Fully-Restricted
    2: Temporary Service Class
    9: Delete of the ID Code
    BB: 01-08: Trunk Restriction Class
    CC: 00-15: Service Feature Class-A
    DD: 00-15: Service Feature Class-B
    EE: 00-15: Service Feature Class-C
    CM20 START
    CM08
    A
    CM42
    CMD5 
    						
    							CHAPTER 3  SYSTEM DATA PROGRAMMING
    Data Assignment for ACF
    NEAX2000 IVS2 OAI System Manual    
    ND-70922 (E), Issue 1.0   Page 55
    DESCRIPTION DATA
    Assign the return result waiting timer for 
    the PBX sent facility.
    (1)
    (2)Y=3
    00
    000-127: 8-508 sec.  
    (4-sec. increments)
    If no data is set, the default setting is 
    8 sec.
    Assign the office number. 
    (1)
    (2)Y=5
    00
    Office No. (Max. 4 digits)
    Assign the Number of ID code digits when 
    AP stops during ACF operation.
    (1)
    (2)Y=B
    00
    0  : No ACF operation
    1  : 1 digit
    2  : 2 digits
    3  : 3 digits
    END
    CMD7
    A 
    						
    							 NEAX2000 IVS2 OAI System ManualPage 56  ND-70922 (E), Issue 1.0
    CHAPTER 3  SYSTEM DATA PROGRAMMING
    Data Assignment for SSF
    DATA ASSIGNMENT FOR SSF
    DESCRIPTION DATA
    Assign the Message Wait Indication (VM) 
    for My Line only or My Line and sub-line 
    on D
    term.(1)
    (2)140
    0  : MW for My Line and sub-lines
    1  : MW for My Line only
    Whether Message Waiting/Message 
    Reminder is reset (turning the MW Lamp 
    off) by answering at the called station 
    when the calling station calls again after 
    setting this feature.(1)
    (2)235
    0: Available
    When a forwarded call is terminated to the 
    VMS via CCIS, Whether Message Waiting 
    from the VMS is provided for the called 
    station.(1)
    (2)376
    0  : To provide
    1  : Not provided
    Assign the Type of Voice Mail System.  (1)
    (2)443
    0: VMS with MCI
    Message Waiting lamp control from VMS 
    with MCI to all stations.
    NOTE:MW lamp control is only 
    available to the stations in the 
    opposite PBX connected with 
    CCIS via MCI.
    Station dialing MW access codes 
    are not allowed over CCIS.(1)
    (2)444
    0: Available
    Assign the Message Waiting/Message 
    Reminder.
    (1)
    (2)YY=03
    X-XXXX: Station No.
    0: To provide (For the station with MW
    lamp)
    START
    CM08
    END
    CM13 
    						
    							CHAPTER 3  SYSTEM DATA PROGRAMMING
    Data Assignment for SMF
    NEAX2000 IVS2 OAI System Manual    
    ND-70922 (E), Issue 1.0   Page 57
    DATA ASSIGNMENT FOR SMF
    DESCRIPTION DATA
    Assign the automatic setting of SMFR for 
    D
    term Sub line.(1)
    (2)429
    0  : Available
    1  : Not available
    Specify OAI SMFN STS (status) for Call 
    Transfer from a station.(1)
    (2)460
    0  : SMFN STS=7
    1  : SMFN STS=0
    Specify whether OAI SMFN is sent when 
    answering a held call.(1)
    (2)461
    0  : Sent
    1  : Not sent
    Specify whether ANI/Caller ID/CPN is 
    sent to OAI terminal.(1)
    (2)462
    0  : Available
    1  : Not available
    Assign the OAI-TSAPI/SCF facility. (1)
    (2)464
    0  : Same as IMX system
    (recommended setting)
    1  : SMFN Off-Hook indication sent
    Assign the SMFN/SSFN delay timer 
    (1)
    (2)Y=A
    02
    0  : Immediate start
    1  : 512 msec. delay
    START
    CM08
    END
    CMD7 
    						
    							NEAX2000 IVS2 OAI System Manual    
    ND-70922 (E), Issue 1.0   Page 59
    CHAPTER 4
    TROUBLESHOOTING
    This chapter explains the troubleshooting information after installing
    the OAI system. 
    						
    							 NEAX2000 IVS2 OAI System ManualPage 60  ND-70922 (E), Issue 1.0
    CHAPTER 4  TROUBLESHOOTING
    Troubleshooting for OAI with RS-232C
    TROUBLESHOOTING FOR OAI WITH RS-232C
    This section explains the troubleshooting information for the OAI system with RS-232C. 
    Table 4-1 shows the cause of trouble and the remedial action.
    Table 4-1  Troubleshooting Information for OAI with RS-232C 
    TROUBLE CAUSE ACTION
    The PN-AP01 
    does not set up. The AP data (07) of PN-AP01 
    has not been assigned by CM05. Assign the AP data (07) by 
    CM05, then initialize the PN-
    AP01 (press SW1 of MP card).
     The AP data (07) of PN-AP01 
    has been assigned to two slot 
    numbers. Delete one data of the two, then 
    initialize the PN-AP01 (press 
    SW1 of MP card).
     The unused data have been 
    assigned by CMA6. Confirm the programming 
    procedure of Chapter 3, then 
    assign the correct data.
    The system 
    cannot 
    communicate 
    with an external 
    processor at all. The cables between the system 
    and an external processor have 
    not been connected properly. Connect the cables properly.
     The attribute data for RS-232C 
    port of PN-AP01 have not been 
    assigned by CMA6. When providing OAI with RS-
    232C, assign the attribute data in 
    accordance with the external 
    processor attribution.
     The attribute data assigned by 
    CMA6 have not coincided with 
    the external processor attribution. When providing the OAI with 
    RS-232C, assign the attribute 
    data in accordance with the 
    external terminal attribution.
     The PN-AP01 has not been 
    initialized after the programming 
    of CMA6. Initialize the PN-AP01 (Move the 
    MB switch on the PN-AP01 up 
    and down).
     The switches of MODEM have 
    not been set properly. Set the switches properly. 
    						
    							CHAPTER 4  TROUBLESHOOTING
    Troubleshooting for OAI with RS-232C
    NEAX2000 IVS2 OAI System Manual    
    ND-70922 (E), Issue 1.0   Page 61
    The system 
    cannot 
    communicate 
    with an external 
    processor at all. In an external processor (RS-
    232C) connection via MODEM, 
    the RTS signal control of RS-232 
    port has been effective (CMA6 
    YY=11, 2nd Data=1). Assign 0 (RTS Signal ON) as the 
    2nd data of CMA6 YY=11.
    The OAI function 
    key of D
    term does 
    not operate. The OAI function key has not 
    been assigned by CM90. Assign the OAI function key to 
    Dterm.
     The operation code for MSF/TMF 
    has not been assigned by CMD7 
    Y=0. Assign the operation code.
     The operation code for MSF/TMF 
    has not been accepted by the 
    external processor. Check the application program of 
    the external processor, then 
    assign correct operation code.
    Table 4-1  Troubleshooting Information for OAI with RS-232C (Continued)
    TROUBLE CAUSE ACTION 
    						
    							 NEAX2000 IVS2 OAI System ManualPage 62  ND-70922 (E), Issue 1.0
    CHAPTER 4  TROUBLESHOOTING
    Troubleshooting for OAI with TCP/IP-Ethernet
    TROUBLESHOOTING FOR OAI WITH TCP/IP-ETHERNET
    This section explains the troubleshooting information for the OAI system with TCP/IP-Ethernet.
    Table 4-2 shows the cause of trouble and the remedial action. When a trouble occurs, do the
    remedial action.
    Troubleshooting Information for ETHER Card
    The lamp indications on the PN-CC01 card on normal condition are as follows:
    NOTE:Confirm connection of a cable if a lamp disappears.
    Table 4-2  Troubleshooting Information for ETHER Card
    TROUBLE CAUSE ACTION
    The system 
    cannot 
    communicate 
    with an external 
    processor at all. The cables between the system 
    and an external processor have 
    not been connected properly. Connect the cable properly.
     The IP Address overlaps with 
    another. Confirm the data set by CMD7 
    Y=9, and assign the correct data.
     The MAC Address overlaps with 
    another. Confirm the switch setting on the 
    PN-CC01 card, and set correctly.
    LAMP NAME COLOR FUNCTION
    RUN Green Flashes at 60 IPM while this card is operating normally.
    LINK Green Lights when link is established. NOTE
    XMT Green Lights when transmitting data.
    RCV Green Lights when receiving data.
    RVP Green Lights when receiving data with own IP Address.
    ERR Not used 
    						
    							CHAPTER 4  TROUBLESHOOTING
    Troubleshooting for OAI with TCP/IP-Ethernet
    NEAX2000 IVS2 OAI System Manual    
    ND-70922 (E), Issue 1.0   Page 63
    Troubleshooting Information for PN-AP01 Card
    Table 4-3  Troubleshooting Information for PN-AP01 Card
    TROUBLE CAUSE ACTION
    The PN-AP01 
    does not set up. The AP data (07) of PN-AP01 
    has not been assigned by CM05. Assign the AP data (07) by 
    CM05, then initialize the PN-
    AP01 (press SW1 of MP card).
     The AP data (07) of PN-AP01 
    has been assigned to two slot 
    numbers. Delete one data of the two, then 
    initialize the PN-AP01 (press 
    SW1 of MP card).
     The unused data have been 
    assigned by CMA6. Confirm the programming 
    procedure of CHAPTER 3, then 
    assign the correct data. 
    						
    							 NEAX2000 IVS2 OAI System ManualPage 64  ND-70922 (E), Issue 1.0
    CHAPTER 4  TROUBLESHOOTING
    Troubleshooting for OAI with TCP/IP-Ethernet
    Replacement Procedure for PN-AP01/PN-CC01 Card
    When replacing the PN-AP01 card or the PN-CC01 card with power on, do the following
    procedure.
    (1) Procedure for PN-AP01 Card
    (a) When unplugging:
     Set the MB switch on the PN-AP01 card to the UP position.
     Remove the BUS cable (48-TW-0.3 CONN CA).
     Unplug the PN-AP01 card from the card slot.
    (b) When plugging in:
     Set the MB switch on the PN-AP01 card to the UP position.
     Plug in the PN-AP01 card to the card slot.
     Connect the BUS cable with the PN-AP01 card.
     Set the MB switch on the PN-AP01 card to the DOWN position.
    (2) Procedure for PN-CC01 Card
    (a) When unplugging:
     Remove the transceiver cable/10 BASE-T cable.
     Remove the BUS cable.
     Set the MB switch on the PN-CC01 to the UP position.
     Unplug the PN-CC01 card from the card slot.
    (b) When plugging in:
     Set the MB switch on the PN-CC01 to the UP position.
     Plug in the PN-CC01 card to the card slot.
     Connect the BUS cable with the PN-CC01 card.
     Connect the 10 BASE-T cable with the PN-CC01 card.
     Set the MB switch on the PN-CC01 to the DOWN position. 
    						