NEAX2000 IVS2 OAI System ManualPage 24 ND-70922 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure (3) Connect the 48-TW-0.3 CONN CA onto the “IP” connector on the PN-AP01 card, as shown in Figure 2-8. (4) Connect the 10 BASE-T twisted pair cable (TIA/EIA category 3 or larger) onto the 10 BASE- T HUB on the Ethernet. Figure 2-8 Cabling 48-TW-0.3 CONN CA and 10 BASE-T Twisted Pair Cable PN-CC01 PN-AP0148-TW-0.3 CONN CA (0.3 m/1 ft.) 10 BASE-T TWISTED PAIR CABLE (TIA/EIA CATEGORY 3 OR LARGER) RS0 IP IP 10 BASE-TCONNECT WITH 10 BASE-T HUB
NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 25 CHAPTER 3 SYSTEM DATA PROGRAMMING This chapter explains the programming procedure to provide the OAI feature to the PBX.
NEAX2000 IVS2 OAI System ManualPage 26 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING How to Read This Chapter HOW TO READ THIS CHAPTER AP Initialization When first programming the OAI system data, initialize the PN-AP01 card using the procedure described in AP01 Initialization. Preparation before Programming Before programming, confirm that the system is under the following conditions. The system is under On-Line mode. (“RUN” lamp is flashing on the MP card.) MB (Make Busy) switch of AP01 card is set to “DOWN” (In Service) position. All the system data pertaining to the stations, trunks and service features are already programmed. NOTE:The tenant service assignment for the stations in the PBX must match the tenant service assignment for those same stations in the User Application Processor (UAP). If these assignments do not match, the OAI features will not work. According to the programming procedures described in this chapter, assign the system data related to the OAI. For details of each command, refer to the Command Manual. In the programming procedure, the meaning of (1), (2) and the markings are as follows. (1) : 1st Data (2) : 2nd Data : Initial Data With the system data clear command (CM00, CM01), the data with this marking is automatically assigned for each command. : System Initialization After entering the data, a system reset (press SW1 on the MP card) is required. : AP Initialization After entering the data, an AP reset (UP and DOWN of MB switch on the AP01 card) is required. INITIAL AP01 INITIAL
CHAPTER 3 SYSTEM DATA PROGRAMMING List of Commands Related to OAI NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 27 LIST OF COMMANDS RELATED TO OAI Table 3-1 shows the commands related to the OAI with each facility (MSF, TMF etc.). Table 3-1 List of Commands Related to OAI ITEMRELATED COMMAND COMMAND No.1ST DATA 2ND DATA MEANING AP01 Initial- ization DataCM05 Y=0 04-15 07 AP Number of PN-AP01 CMD6 Y=0 0000 CCC PN-AP01 Memory All Clear OAI Com- muni- cation Data (TCP/ IP)CMD7 Y=9 00-03 0-255 IP Address of TCP/IP-Ethernet OAI Com- muni- cation Data (RS- 232C)CMA6 YY=04 3 0-6 AP Port Data CMA6 YY=05 3 1 CMA6 YY=06 3 7 CMA6 YY=07 3 1 CMA6 YY=08 3 1 CMA6 YY=09 3 06 CMA6 YY=10 3 0/1 CMA6 YY=11 3 0/1 CMA6 YY=12 3 0/1 CMA6 YY=20 3 2 CMA6 YY=21 3 0 CMA6 YY=24 3 1
NEAX2000 IVS2 OAI System ManualPage 28 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING List of Commands Related to OAI MSFCM10 000-763 EB000- EB127Digital Announcement Trunk Card No. CM12 YY=02 Station No. 00-15 Service Restriction Class CM15 YY=59 00-15 1 CM20 Y=0-3 Access Code A084 MSF Access Code CM20 Y=0-3 Access Code A100-A102 Digital Announcement Trunk Access Code CM41 Y=0 56 00-99 Message Replay Timer/Tone Sending Timer CM49 YY=00 000-127 10 Announcement Service for OAI CM90 YY=00 My Line No. + + Key No.F1032-F1047 OAI Function Key CMD7 Y=0 F1032- F1047128-191 MSF Operation Code CMD7 Y=0 F1032- F1047DCX (X=1-3) Digit Number of Digit Code CMD7 Y=1 Access Code 128-191 MSF Operation Code CMD7 Y=2 000-127 1000-1127 Digital Announcement Trunk Card No. CMD7 Y=3 00 000-127 RR Timer CMD7 Y=4 00 00-32 Maximum number of terminals to be in MSF simultaneously CMD7 Y=6 Digit Code 128-191 Operation Code for MSF CMD7 Y=7 F1032- F104700/01 Chime from D term when Receiving RR Signal TMFCM90 YY=00 My Line No. + + Key No.F1032-F1047 OAI Function Key Table 3-1 List of Commands Related to OAI (Continued) ITEMRELATED COMMAND COMMAND No.1ST DATA 2ND DATA MEANING , ,
CHAPTER 3 SYSTEM DATA PROGRAMMING List of Commands Related to OAI NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 29 TMFCMD7 Y=0 F1032- F1047192-255 TMF Operation Code CMD7 Y=0 F1032- F1047DCX (X=1-3) Digit Number of Digit Code CMD7 Y=3 00 000-127 RR Timer CMD7 Y=4 01 00-32 Maximum number of terminals to be in TMF simultaneously CMD7 Y=6 Digit Code 192-255 Operation Code for TMF CMD7 Y=7 F1032- F104700/01 Chime from D term when Receiving RR Signal CMD7 Y=8 00-03 00/01 Chime from D term, Display Guidance when setting up TMF SCFCM08 465 0/1 Facility Error detail information from PBX to computer CM10 000-763 EB002- EB127Digital Announcement Trunk Card No. CM11 000-255 Virtual-Line numberVirtual Line number (Assign only one per system) CM17 Y=0 Station No. Another Station No.UCD Group CM17 Y=1 Station No. 2/3 Member station/Pilot station CM17 Y=2 Station No. 00-15 UCD Group No. CM17 Y=A Station No. 0/1 Method of Sending Multi- Connection Announcement CM41 Y=0 56 01-99 Message Replay Timer/Tone Sending Timer CM41 Y=0 65 01-99 Ringing Time CM41 Y=0 67 01-32 OAI Announcement Connection Timer Table 3-1 List of Commands Related to OAI (Continued) ITEMRELATED COMMAND COMMAND No.1ST DATA 2ND DATA MEANING
NEAX2000 IVS2 OAI System ManualPage 30 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING List of Commands Related to OAI SCFCM42 10 01-06 Account Code Max. digit (SCF FID=1, 3, 4, 7) CM49 YY=00 000-127 10/1602-1663 Announcement Service for OAI/ Message Group No. for Multi- Connection Announcement Service for OAI CMD7 Y=2 000-127 1000-1127 Digital Announcement Trunk Card No. FLFCM08 216 1 AP (PN-AP01) CM08 217 1 AP (PN-AP01) CM15 YY=31 00-15 0/1 Authorization Code/Forced Account Code CM20 Y=0-3 Access Code A157 First Digit of Authorization Code CM42 11 01-10 Max. Number of Digit for Authorization Code CMD7 Y=5 00 X-XXXX Office Number CMD7 Y=A 00 0/1 Recognition of AP database CMD7 Y=A 01 0/1 Omission of AP database KTFCM90 YY=00 My Line No. + + Key No.F1032-F1047 OAI Function Key ACFCM08 217 0/1 Processor for Checking ID Cords CM08 362 0/1 SST after Dialing the Access Code for ID Code Class Change CM20 Y=0-3 Access Code A086/A087 Access Code for ID Code Class Change CM42 11-13 01-10 Number of digits for Authorization Code/Forced Account Code/DISA Table 3-1 List of Commands Related to OAI (Continued) ITEMRELATED COMMAND COMMAND No.1ST DATA 2ND DATA MEANING ,
CHAPTER 3 SYSTEM DATA PROGRAMMING List of Commands Related to OAI NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 31 ACFCMD5 Y=3 ID code ABBCCDDEE Temporary Class Data CMD7 Y=3 00 000-127 RR Timer CMD7 Y=5 00 XXXX Office Number CMD7 Y=B 00 0-3 Number of Digits for ID Codes when AP Stops TCF None NTF None ADF None SSF (MW)CM08 140 0/1 Message Wait Indication (MW) CM08 235 0 Message Waiting/Message Reminder reset CM08 376 0/1 VMS via CCIS CM08 443 0 VMS with MCI CM08 444 0/1 Message Waiting lamp control CM13 YY=03 Station No. 0 Message Waiting/Message Reminder Table 3-1 List of Commands Related to OAI (Continued) ITEMRELATED COMMAND COMMAND No.1ST DATA 2ND DATA MEANING
NEAX2000 IVS2 OAI System ManualPage 32 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING List of Commands Related to OAI SMFCM08 429 0/1 D term subline CM08 460 0/1 SMFN STS (Status) CM08 461 0/1 SMFN when answering a held call CM08 462 0/1 ANI/Caller ID/CPN to OAI Terminal CM08 464 0/1 TSAPI/SCF facility CMD7 Y=A 02 0/1 SMFN/SSFN Delay Timer MRF None Health checkNone Table 3-1 List of Commands Related to OAI (Continued) ITEMRELATED COMMAND COMMAND No.1ST DATA 2ND DATA MEANING
CHAPTER 3 SYSTEM DATA PROGRAMMING AP01 Initialization NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 33 AP01 INITIALIZATION DESCRIPTION DATA Assign an AP number to the AP01 card. NOTE:The AP number must match the SENSE switch settings on the AP01 card. (1) (2)Y=0 AP Number (04-15) 07: AP01 card Load the initial data into the AP01 card. (1) (2)Y=0 0000 CCC CMD6 START END CM05 INITIAL