    							 NEAX2000 IVS2 OAI System ManualPage 34  ND-70922 (E), Issue 1.0
    CHAPTER 3  SYSTEM DATA PROGRAMMING
    OAI Communication Data Assignment (TCP/IP)
    OAI COMMUNICATION DATA ASSIGNMENT (TCP/IP)
    NOTE 1:The IP Address must be assigned to the 1st data 00-03 as follows.
    IP Address: AAA.BBB.CCC.DDD [AAA-DDD: 2nd Data (2)]
    NOTE 2:When setting the 2nd Data as shown in Table 3-2 IP Address Assignment Patterns
    (PN-CC01 Card) (See Page 35), note that the setting data is different from the data
    actually assigned.
    IP Address: AAA.BBB.CCC.DDD
    DESCRIPTION DATA
    Assign the IP Address of TCP/IP-Ethernet.
    NOTE 1, NOTE 2
    
    (1)
    (2)Y=9
    00-03: Division No. of IP Address
    0-255: Address Data (1-3 digits)
    1st Data (1) 00: AAA
    01: BBB
    02: CCC
    03: DDD
    START
    CMD7
    END
    AP01 INITIAL 
    						
    							CHAPTER 3  SYSTEM DATA PROGRAMMING
    OAI Communication Data Assignment (TCP/IP)
    NEAX2000 IVS2 OAI System Manual    
    ND-70922 (E), Issue 1.0   Page 35
    Table 3-2  IP Address Assignment Patterns (PN-CC01 Card)
    PATTERNINPUT DATA (2ND DATA)
    ASSIGNED DATA
    AAA BBB CCC DDD
    When no data 
    or all 0 is input
    No data No data No data No data4C.A4.XX.XX (HEX)
    4C.A4: Fixed
    XX.XX: According to the 
    switch setting of 
    SW1 (D15-D8) 
    and SW2 (D7-D0)
    (The IP Address is the 
    same as lower 32 bits of 
    MAC Address.)
    0000
    When the data 
    only for 
    Address AAA is 
    input
    0≤AAA
    ≤127000A.A4.XX.XX (HEX)
    A.A4: Fixed
    XX.XX: According to the 
    switch setting of 
    SW1 (D15-D8) 
    and SW2 (D7-D0)
    (The lower 24 bits of IP 
    Address is the same as the 
    lower 24 bits of MAC 
    Address.)
    When the data 
    only for 
    Address AAA 
    and BBB is 
    input 128≤AA
    A
    ≤1910≤BBB
    ≤2550A.B.XX.XX (HEX)
    A.B: Fixed
    XX.XX: According to the 
    switch setting of 
    SW1 (D15-D8) 
    and SW2 (D7-D0)
    (The lower 16 bits of IP 
    Address is the same as the 
    lower 16 bits of MAC 
    Address.) 
    						
    							 NEAX2000 IVS2 OAI System ManualPage 36  ND-70922 (E), Issue 1.0
    CHAPTER 3  SYSTEM DATA PROGRAMMING
    OAI Communication Data Assignment (RS-232C)
    OAI COMMUNICATION DATA ASSIGNMENT (RS-232C)
    DESCRIPTION DATA
    Assign the attribute data for RS-232C port 
    of the PN-AP01.
    (1)
    (2)YY=04 Data Transmission Speed of 
    RS-232C port
    3
    0: 150 bps
    1: 300 bps
    2: 600 bps
    3: 1200 bps
    4: 2400 bps
    5: 4800 bps
    6: 9600 bps
    
    (1)
    (2)YY=05 Parity Check
    3
    1  : Ineffective
    
    (1)
    (2)YY=06 Synchronous/Asynchronous
    3
    7  : Asynchronous
    
    (1)
    (2)YY=07 Duplex/Half-duplex
    3
    1  : Duplex
    START
    CMA6
    A
    AP01 INITIAL 
    						
    							CHAPTER 3  SYSTEM DATA PROGRAMMING
    OAI Communication Data Assignment (RS-232C)
    NEAX2000 IVS2 OAI System Manual    
    ND-70922 (E), Issue 1.0   Page 37
    DESCRIPTION DATA
    
    (1)
    (2)YY=08 Stop Bit
    3
    1  : 1-Stop Bit
    
    (1)
    (2)YY=09 Type of Code
    3
    06: JIS (8-bit)
    
    (1)
    (2)YY=10 Flow Control by DCD Signal
    3
    0  : Ineffective
    1 :Effective
    
    (1)
    (2)YY=11 RTS Signal Control
    3
    0  : Ineffective (RTS Signal ON)
    1 :Effective
    NOTE:When connecting an external
    processor with RS-232C in-
    terface via MODEM, assign 0
    (RTS Signal ON) as the 2nd
    data.
    
    (1)
    (2)YY=12 Designation of Signal for 
    Detecting Line Disconnection
    3
    0  : DCD (with MODEM)
    1  : DSR (without MODEM)
    
    (1)
    (2)YY=20 Designation of Facility
    3
    2: OAI
    
    (1)
    (2)YY=21 Priority
    3
    0: 1st Priority
    
    (1)
    (2)YY=24 Kind of Procedure
    3
    1: Free Wheel
    END
    CMA6
    A
    AP01 INITIAL 
    						
    							 NEAX2000 IVS2 OAI System ManualPage 38  ND-70922 (E), Issue 1.0
    CHAPTER 3  SYSTEM DATA PROGRAMMING
    Data Assignment for MSF
    DATA ASSIGNMENT FOR MSF
    To start up MSF from Dterm by using an OAI function key:
    DESCRIPTION DATA
    Assign the OAI function key for starting up 
    MSF to a D
    term.
    (1)
    (2)YY=00
    My Line No. +   + Key No.
    F1032-F1047: OAI Function Key 
    No. 0-15
    When pressing the OAI function key to 
    start up MSF, assign the operation code 
    to the OAI function key assigned by 
    CM90.
    (1)
    (2)Y=0
    F1032-F1047: OAI Function Key
    No. 0-15
    128-191: Operation Code for MSF
    When dialing a digit code (1-3 digits) after 
    pressing OAI function key to start up 
    MSF, assign the digit number of digit 
    code, then assign the operation code to 
    the digit code.
    (1)
    (2)Y=0
    F1032-F1047: OAI Function Key
    No. 0-15
    DCX (X=1-3) : Digit Number of Digit
    Code
    
    (1)
    (2)Y=6
    X-XXX: Digit Code (X=0-9, #)
    128-191: Operation Code for MSF
    Assign the waiting timer for receiving an 
    answer signal (RR signal) after starting up 
    MSF, if required.
    (1)
    (2)Y=3
    00
    000-127: 8-508 sec. 
    (4-sec. increments)
    If no data is set, the default setting is 8 sec.
    Specify a chime from D
    term when 
    receiving RR signal of MSF.
    (1)
    (2)Y=7
    F1032-F1047: OAI Function Key 
    No. 0-15
    00  : Not sent
    01  : To send
    CMD7 START
    CM90
    END
    , 
    						
    							CHAPTER 3  SYSTEM DATA PROGRAMMING
    Data Assignment for MSF
    NEAX2000 IVS2 OAI System Manual    
    ND-70922 (E), Issue 1.0   Page 39
    To start up MSF from PB Telephone/Dterm by using an access code:
    DESCRIPTION DATA
    Assign the Service Restriction Class for 
    starting up MSF to the required stations.
    NOTE:After starting up the MSF from a 
    PB telephone or Dterm, the PB re-
    ceiver is busy during MSF mode. 
    Therefore, you must make sure 
    that a call origination is not avail-
    able if all PB receivers are used. 
    To prevent the “all busy,” we rec-
    ommend using the OAI function 
    key on D
    term, as the PB receiver 
    is not used for the Dterm.
    (1)
    (2)YY=02 
    X-XXXX: Station No. 
    XX ZZ
    ZZ: 00-15  : Service Restriction Class
     B
    
    (1)
    (2)YY=59 
    00-15: Service Restriction Class B
    assigned by CM12 Y=02
    1 : Allow
    Assign the access code for starting up 
    MSF.
    (1)
    (2)Y=0-3 Number Plan Group 0-3
    X-XXXX: Access Code for MSF
    A084
    Assign the operation code to the access 
    code assigned by CM20>A084.
    NOTE 1:The operation code means a
    number to designate each OAI
    application.
    NOTE 2:The maximum number of
    operation code is 16.
    (1)
    (2)Y=1
    X-XXXX: Access Code assigned by
    CM20>A084
    128-191: Operation Code for MSF
    Assign the waiting timer for receiving an 
    answer signal after starting up MSF, if 
    required.
    (1)
    (2)Y=3
    00
    000-127: 8-508 sec.
    (4-sec. increments)
    If no data is set, the default setting is 000 
    (8-sec.).
    Assign the number of the terminal (PB 
    telephone) to be in the terminal mode 
    simultaneously.•
    (1)
    (2)Y=4
    00
    00  -32 : Number of Terminal
    CM20 START
    CM12
    A
    CM15
    CMD7 
    						
    							 NEAX2000 IVS2 OAI System ManualPage 40  ND-70922 (E), Issue 1.0
    CHAPTER 3  SYSTEM DATA PROGRAMMING
    Data Assignment for MSF
    DESCRIPTION DATA
    When sending a message through the 
    Digital Announcement Trunk (PN-2DATA) 
    to PB telephone/D
    term user by using TCF-
    D facility:
    When sending a tone to PB telephone/
    D
    term user by using TCF-D facility:
    When not sending a message or tone:
    A
    CMD7
    C
    B
    END 
    						
    							CHAPTER 3  SYSTEM DATA PROGRAMMING
    Data Assignment for MSF
    NEAX2000 IVS2 OAI System Manual    
    ND-70922 (E), Issue 1.0   Page 41
    DESCRIPTION DATA
    Assign a Digital Announcement Trunk 
    card number to the required LEN.
    NOTE 1:The Digital Announcement 
    Trunk card number must be 
    assigned to the first LEN (Level 
    0), the third LEN (Level 2), the 
    fifth LEN (Level 4) and the 
    seven LEN (Level 6) of each LT 
    slot.
    NOTE 2:EB000 and EB001 are 
    dedicated to built-in Digital 
    Announcement Trunk of the MP 
    card.(1)
    (2)LEN: 000-763
    EB002-EB127: Digital Announcement
    Trunk Card No.
    For PIM0/1: EB002-EB031
    For PIM2/3: EB032-EB063
    For PIM4/5: EB064-EB095
    For PIM6/7: EB096-EB127
    NOTE 2
    Assign the function of the Digital 
    Announcement Trunk card.
    (1)
    (2)YY=00
    000-001: Built-in DAT on MP card
    002-127: Digital Announcement Trunk
    Card No. assigned by CM10
    (EB002-EB127)
    10: Announcement Service in the OAI
    Terminal mode
    To record, replay or delete a message, 
    assign the respective Digital 
    Announcement Trunk access code.
    (1)
    (2)Y=0-3 Numbering Plan Group 0-3
    X-XXXX: Access Code
    A100: Record
    A101: Replay
    A102: Delete
    Specify the message replay timer in the 
    OAI terminal mode, if required.
    (1)
    (2)Y=0
    56
    01-99: 0-396 sec. (4 sec. increments)
    If no data is set, the default setting is 20-24 
    sec.
    Assign the Digital Announcement Trunk 
    card number.
    (1)
    (2)Y=2 
    000-127: Message No. 
    1 XXX
    XXX: 000-127: Digital Announcement
    Trunk Card No.
    assigned by CM10
    CM10
    B
    END
    CMD7
    CM41
    CM20
    CM49 
    						
    							 NEAX2000 IVS2 OAI System ManualPage 42  ND-70922 (E), Issue 1.0
    CHAPTER 3  SYSTEM DATA PROGRAMMING
    Data Assignment for MSF
    DESCRIPTION DATA
    Specify the tone sending timer in the OAI 
    terminal mode, if required.
    (1)
    (2)Y=0
    56
    01-99: 0-396 sec. (4 sec. increments)
    If no data is set, the default setting is 20-24 
    sec.CM41
    C
    END 
    						
    							CHAPTER 3  SYSTEM DATA PROGRAMMING
    Data Assignment for TMF
    NEAX2000 IVS2 OAI System Manual    
    ND-70922 (E), Issue 1.0   Page 43
    DATA ASSIGNMENT FOR TMF
    DESCRIPTION DATA
    Assign the OAI function key for starting up 
    TMF to a D
    term.
    (1)
    (2)YY=00
    My Line No. +   + Key No.
    F1032-F1047: OAI Function Key 
    No. 0-15
    When you start up the TMF by pressing 
    the OAI function key, assign the operation 
    code to the OAI function key assigned by 
    CM90.
    (1)
    (2)Y=0
    F1032-F1047: OAI Function Key
    No. 0-15
    192-255: Operation Code for TMF
    When you start up the TMF by dialing a 
    digit code (1-3 digits) after pressing the 
    OAI function key, assign the digit number 
    of the digit code, then assign the 
    operation code to the digit code.
    (1)
    (2)Y=0
    F1032-F1047: OAI Function Key
    No. 0-15
    DCX (X=1-3): Digit Number of Digit
    Code
    
    (1)
    (2)Y=6
    X-XXX: Digit Code (X=0-9, #)
    192-255: Operation Code for TMF
    Assign the waiting timer for receiving an 
    answer signal after starting up the TMF, if 
    required.
    (1)
    (2)Y=3
    00
    000-127: 8-508 sec. in 4-sec.
    increments
    If no data is set, the default setting is 
    8 seconds.
    Assign the maximum number of terminals 
    to be in TMF simultaneously.
    (1)
    (2)Y=4
    01
    00 : 32 terminals
    01-32 : Number of Terminal
    CMD7 START