CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Card NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 75 Lamp Indications Switch Settings LAMP NAMECOLOR FUNCTION RUN Green Flashes at 60 IPM while this card is operating normally. LINK Green Remains lit when link is established. XMT Green Remains lit when it is transmitting the data. RCV Green Remains lit when it is receiving the data. RVP Green Remains lit only when it is receiving the data with its own IP address. ERR – Not used SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTIONCHECK MB (Toggle SW) NOTE 1UP For make-busy For normal operation (Continued) ON DOWN
NEAX2000 IVS2 OAI System ManualPage 76 ND-70922 (E), Issue 1.0 CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Card SW1 (DIP SW) NOTE 21 (D15) ON 2 (D14) ON 3 (D13) ON 4 (D12) OFF 5 (D11)ON OFF 6 (D10)ON OFF 7 (D9)ON OFF 8 (D8)ON OFF SW2 (DIP SW) NOTE 21 (D7)ON OFF 2 (D6)ON OFF 3 (D5)ON OFF 4 (D4)ON OFF 5 (D3)ON OFF 6 (D2)ON OFF 7 (D1)ON OFF 8 (D0)ON OFF SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTIONCHECK 1 23 45 67 8ON MAC ADDRESS SWITCH SETTING 00004CA4 X X X X (HEX) FixedSW1-1 (D15) SW1-2 (D14) SW1-3 (D13) SW1-4 (D12)ON/OFF ON/OFF ON/OFF ON/OFF SW1-5 (D11) SW1-6 (D10) SW1-7 (D9) SW1-8 (D8)ON/OFF ON/OFF ON/OFF ON/OFF SW2-1 (D7) SW2-2 (D6) SW2-3 (D5) SW2-4 (D4)ON/OFF ON/OFF ON/OFF ON/OFF SW2-5 (D3) SW2-6 (D2) SW2-7 (D1) SW2-8 (D0)ON/OFF ON/OFF ON/OFF ON/OFFO N :0 O F F :1 1 23 45 67 8ON
CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Card NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 77 NOTE 1:When the power is on, flip the MB switch to ON (UP position) before plugging/ unplugging the Circuit card. NOTE 2:Each equipment must have a unique MAC address to distinguish between systems. Therefore, when more than one PBX is installed in the same network, assign the lower 4 digits of the following MAC address by SW1 and SW2 to prevent duplicate addresses. 00004CA4 XX XX (HEX) According to the switch setting of SW2 (D7-D0) According to the switch setting of SW1 (D15-D8) Fixed
NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 79 APPENDIX DEFINITION OF V.24 SIGNAL LEADS This appendix contains the definition of V.24 signal leads.
NEAX2000 IVS2 OAI System ManualPage 80 ND-70922 (E), Issue 1.0 APPENDIX DEFINITION OF V.24 SIGNAL LEADS PIN No.SIGNAL-NAME DIRECTION OF SIGNALMEANING RS-232CJIS C 6361CCITT V.24ANOTHER 1 AA (FG) 101 GND Frame Ground 2BASD103 TXD DTE Send Data 3BBRD104 RXD DCEReceive Data 4CARS105 RTS DTE Request to Send 5CBCS106 CTS DCEClear to Send 6CCDR107 DSR DCEData Set Ready 7 AB SG 102 GND Signal Ground 8 CF CD 109 DCD DCEData Channel Receive Carrier Detect 9 Not used 10 Not used 11 PB Peripheral Busy 12 SCF BCD 122 DCEBackward Channel Receive Carrier Detect 13 SCB BCS 121 DCEBackward Channel Send (OK) 14 SBA BSD 118 DTE Backward Channel Send Data 15 DB ST2 114 TXC (2) DCESend Signal Element Timing 16 SBB BRD 119 DCEBackward Channel Receive Data 17 DD RT 115 RXC DCEReceive Signal Element Timing 18 Not used 19 SCA BRS 120 DTE Backward Channel Send Detect 20 CD ER 108/2 DTR DTE Data Terminal Ready 21 CG SQD 110 DCEData Signal Quality Detect 22 CE CI 125 RI DCECall Indication 23 CI, CH SRS 112, 111 Data Signal Speed Choice 24 DA ST1 113 TXC (1) DTE Send Signal Element Timing 25 Not used