NEAX2000 IVS2 OAI System ManualPage 44 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for TMF DESCRIPTION DATA Specify a chime from Dterm when receiving RR signal of TMF. (1) (2)Y=7 F1032-F1047: OAI Function Key No. 0-15 00 : Not sent 01 : To send Specify a chime from D term when setting up TMF. (1) (2)Y=8 00: Chime before sending terminal messages (when pressing the OAI Function key) 02: Chime after sending terminal messages 00 : No ring 01 : Ring Specify the display of guidance on D term when setting up TMF. (1) (2)Y=8 01: Display of guidance before sending terminal messages (When pressing the OAI Function key) 03: Display of guidance after sending terminal messages 00 : To display 01 : Not displayed END CMD7 A
CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for SCF NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 45 DATA ASSIGNMENT FOR SCF To provide Call Origination with Ringing (FID=3): To originate a call with Account Code (FID=1, 3, 4, 7): DESCRIPTION DATA Assign the Ringing Tone Sending time for SCF of OAI. (1) (2)Y=0 65: OAI RGT Sending Time 01-99: 4-396 sec. (4 sec. increments) If no data is set, the default setting is 12-16 sec. DESCRIPTION DATA Specify the maximum number of digits for Account Code.(1) (2)10 01-16 : 1 digit-16 digits 10 : 10 digits START CM41 END START CM42 END
NEAX2000 IVS2 OAI System ManualPage 46 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for SCF If the Digital Announcement Trunk or Tone is provided, do the following programming: DESCRIPTION DATA Assign a Digital Announcement Trunk card number to the required LEN. NOTE 1:The Digital Announcement Trunk card number must be assigned to the first LEN (Level 0), the third LEN (Level 2), the fifth LEN (Level 4) and the seven LEN (Level 6) of each LT slot. NOTE 2:EB000 and EB001 are dedicated to built-in Digital Announcement Trunk of the MP card.(1) (2)LEN: 000-763 EB002-EB127: Digital Announcement Trunk Card No. For PIM0/1: EB002-EB031 For PIM2/3: EB032-EB063 For PIM4/5: EB064-EB095 For PIM6/7: EB096-EB127 NOTE 2 Assign the Message Replay timer/Tone Sending timer in the OAI terminal mode. (1) (2)Y=0 56: Message Replay Timer/Tone Sending Timer 01-99: 4-396 sec. (4 sec. increments) If no data is set, the default setting is 20- 24 sec. Assign the function of the Digital Announcement Trunk card. (1) (2)YY=00 000-001: Built-in DAT on MP card 002-127: Digital Announcement Trunk Card No. assigned by CM10 (EB002-EB127) 10: Announcement Service in the OAI Terminal mode. Assign the Digital Announcement Trunk card number. (1) (2)Y=2 000-127: Message No. 1 XXX XXX: 000-127: Digital Announcement Trunk Card No. START CM10 END CMD7 CM49 CM41
CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for SCF NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 47 To provide Queue Connection (FID=4): To provide the system with a monitor number: DESCRIPTION DATA Assign the UCD group. (1) (2)Y=0 X-XXXX: Station No. X-XXXX: Another station No. to be linked Assign the Pilot station and Member station to queuing for SCF of OAI. (1) (2)Y=1 Distinction of Member station from Pilot station X-XXXX: Station No. 2: Off Hook suppressed 3: Pilot station (Monitor No.) * Unable to place or receive a call. Assign the UCD group number. (1) (2)Y=2 X-XXXX: UCD Station No. 00-15: UCD Group 00-15 DESCRIPTION DATA Assign a virtual station number to be used as the monitored number.(1) (2)000-255: Virtual LEN X-XXXX: Virtual-Line number (Assign only one per system.) Assign the Pilot station and Member station to queuing for SCF or OAI. (1) (2)Y=1 Distinction of Member station from Pilot station X-XXXX: Station No. 2: Member station 3: Pilot station (Monitor No.) * Unable to place or receive a call. Assign the UCD group number. (1) (2)Y=2 X-XXXX: UCD station No. 00-15: UCD Group 00-15 START CM17 END START CM11 END CM17
NEAX2000 IVS2 OAI System ManualPage 48 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for SCF To provide Announcement Call (FID=5): DESCRIPTION DATA Assign a Digital Announcement Trunk card number to the required LEN. NOTE 1:The Digital Announcement Trunk card number must be assigned to the first LEN (Level 0), the third LEN (Level 2), the fifth LEN (Level 4) and the seven LEN (Level 6) of each LT slot. NOTE 2:EB000 and EB001 are dedicated to built-in Digital Announcement Trunk of the MP card.(1) (2)LEN: 000-763 EB002-EB127: Digital Announcement Trunk Card No. For PIM0/1: EB002-EB031 For PIM2/3: EB032-EB063 For PIM4/5: EB064-EB095 For PIM6/7: EB096-EB127 NOTE 2 Assign the Pilot station and Member station to queuing for SCF of OAI. When sending an announcement from the beginning on the Multi-Connection Announcement Service, set this data to “3”. (1) (2)Y=1 Distinction of Member station from Pilot station X-XXXX: Station No. 2: Originate Suppress 3: Pilot station (Monitor No.) * Unable to place nor receive a call. NOTE:2 is for Member station 3 is for Pilot station Assign the method to send Multi- Connection Announcement. When sending an announcement from the beginning on the Multi-Connection Announcement, set this data to “1”. (1) (2)Y=A X-XXXX: Pilot station No. 0 : To be sent periodically 1 : To be sent only once When sending an announcement from the beginning on the Multi-Connection Announcement, assign the latency time of sending the announcement after receiving SCF FID=5. (1) (2)Y=0 67: OAI Announcement Connection Timer 01-32: 4-128 sec. (4 sec. increments) If no data is set, the default setting is 8-12 sec. CM17 START CM10 A CM41
CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for SCF NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 49 DESCRIPTION DATA Assign the function of the Digital Announcement Trunk card. (1) (2)YY=00 000-001: Built-in DAT on MP card 002-127: Digital Announcement Trunk Card No. assigned by CM10 (EB002-EB127) 10: Announcement Service for OAI 16 XX XX: Message Group No. (02-63) for Multi-Connection Announcement Service for OAI. Assign the Digital Announcement Trunk card number. (1) (2)Y=2 000-127: Message No. 1 XXX XXX: 000-127: Digital Announcement Trunk Card No. END CM49 A CMD7
NEAX2000 IVS2 OAI System ManualPage 50 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for SCF To provide Conversation Monitoring (FID=6) and Call Conferencing (FID=8): DESCRIPTION DATA Assign the Ringing Tone Sending time for SCF of OAI. (1) (2)Y=0 65: OAI RGT Sending Time 01-99: 4-396 sec. (4 sec. increments) If no data is set, the default setting is 12-16 sec. START CM41 END
CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for FLF NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 51 DATA ASSIGNMENT FOR FLF DESCRIPTION DATA Assign the access code to recognize Authorization Code for FLF. NOTE:The access code should be as- signed to the first one, two or three digits of Authorization Code. For example: (1) (2)Y=0-3 X-XXXX: Access Code A157 Assign the maximum number of digits for Authorization Code.(1) (2)11 01-10 : Max. Number of Digits START CM20 CM42 A1 2 3 4 5 6 (Authorization Code) Max. No. of digits assigned by CM42>11 Access Code assigned by CM20>A157
NEAX2000 IVS2 OAI System ManualPage 52 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for FLF DESCRIPTION DATA Assign the recognition of AP database by RR message. (1) (2)Y=A 00 0 : To provide 1 : Not provided Assign the omission of AP database for information added to RR message. (1) (2)Y=A 01 0 : Not omitted 1 : To omit Assign the office number. (1) (2)Y=5 00 Office No. (Max. 4 digits) Assign the processor for Authorization Code/Forced Account Code.(1) (2)216 1 : AP (PN-AP01) Assign the processor for a Remote Access to System (DISA).(1) (2)217 1 : AP (PN-AP01) Allow the Authorization Code/Forced Account Code in required Service Restriction Class. (1) (2)YY=31 00-15: Service Restriction Class A assigned by CM12 YY=02. 0 : Restrict 1 : Allow END CMD7 A CM08 CM15
CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for KTF NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 53 DATA ASSIGNMENT FOR KTF DESCRIPTION DATA Assign the OAI function key for starting up FLF to a D term. (1) (2)YY=00 My Line No. + + Key No. F1032-F1047: OAI Function Key No. 0-15 START CM90 END ,