NEC Neax 2000 Ivs2 Oai System Manual
Here you can view all the pages of manual NEC Neax 2000 Ivs2 Oai System Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 41
NEAX2000 IVS2 OAI System ManualPage 34 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING OAI Communication Data Assignment (TCP/IP) OAI COMMUNICATION DATA ASSIGNMENT (TCP/IP) NOTE 1:The IP Address must be assigned to the 1st data 00-03 as follows. IP Address: AAA.BBB.CCC.DDD [AAA-DDD: 2nd Data (2)] NOTE 2:When setting the 2nd Data as shown in Table 3-2 IP Address Assignment Patterns (PN-CC01 Card) (See Page 35), note that the setting data is different from the data actually assigned. IP...
Page 42
CHAPTER 3 SYSTEM DATA PROGRAMMING OAI Communication Data Assignment (TCP/IP) NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 35 Table 3-2 IP Address Assignment Patterns (PN-CC01 Card) PATTERNINPUT DATA (2ND DATA) ASSIGNED DATA AAA BBB CCC DDD When no data or all 0 is input No data No data No data No data4C.A4.XX.XX (HEX) 4C.A4: Fixed XX.XX: According to the switch setting of SW1 (D15-D8) and SW2 (D7-D0) (The IP Address is the same as lower 32 bits of MAC Address.) 0000 When the...
Page 43
NEAX2000 IVS2 OAI System ManualPage 36 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING OAI Communication Data Assignment (RS-232C) OAI COMMUNICATION DATA ASSIGNMENT (RS-232C) DESCRIPTION DATA Assign the attribute data for RS-232C port of the PN-AP01. (1) (2)YY=04 Data Transmission Speed of RS-232C port 3 0: 150 bps 1: 300 bps 2: 600 bps 3: 1200 bps 4: 2400 bps 5: 4800 bps 6: 9600 bps (1) (2)YY=05 Parity Check 3 1 : Ineffective (1) (2)YY=06 Synchronous/Asynchronous 3 7 :...
Page 44
CHAPTER 3 SYSTEM DATA PROGRAMMING OAI Communication Data Assignment (RS-232C) NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 37 DESCRIPTION DATA (1) (2)YY=08 Stop Bit 3 1 : 1-Stop Bit (1) (2)YY=09 Type of Code 3 06: JIS (8-bit) (1) (2)YY=10 Flow Control by DCD Signal 3 0 : Ineffective 1 :Effective (1) (2)YY=11 RTS Signal Control 3 0 : Ineffective (RTS Signal ON) 1 :Effective NOTE:When connecting an external processor with RS-232C in- terface via MODEM, assign 0 (RTS Signal...
Page 45
NEAX2000 IVS2 OAI System ManualPage 38 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for MSF DATA ASSIGNMENT FOR MSF To start up MSF from Dterm by using an OAI function key: DESCRIPTION DATA Assign the OAI function key for starting up MSF to a D term. (1) (2)YY=00 My Line No. + + Key No. F1032-F1047: OAI Function Key No. 0-15 When pressing the OAI function key to start up MSF, assign the operation code to the OAI function key assigned by CM90. (1) (2)Y=0...
Page 46
CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for MSF NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 39 To start up MSF from PB Telephone/Dterm by using an access code: DESCRIPTION DATA Assign the Service Restriction Class for starting up MSF to the required stations. NOTE:After starting up the MSF from a PB telephone or Dterm, the PB re- ceiver is busy during MSF mode. Therefore, you must make sure that a call origination is not avail- able if all PB receivers are used. To...
Page 47
NEAX2000 IVS2 OAI System ManualPage 40 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for MSF DESCRIPTION DATA When sending a message through the Digital Announcement Trunk (PN-2DATA) to PB telephone/D term user by using TCF- D facility: When sending a tone to PB telephone/ D term user by using TCF-D facility: When not sending a message or tone: A CMD7 C B END
Page 48
CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for MSF NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 41 DESCRIPTION DATA Assign a Digital Announcement Trunk card number to the required LEN. NOTE 1:The Digital Announcement Trunk card number must be assigned to the first LEN (Level 0), the third LEN (Level 2), the fifth LEN (Level 4) and the seven LEN (Level 6) of each LT slot. NOTE 2:EB000 and EB001 are dedicated to built-in Digital Announcement Trunk of the MP card.(1)...
Page 49
NEAX2000 IVS2 OAI System ManualPage 42 ND-70922 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for MSF DESCRIPTION DATA Specify the tone sending timer in the OAI terminal mode, if required. (1) (2)Y=0 56 01-99: 0-396 sec. (4 sec. increments) If no data is set, the default setting is 20-24 sec.CM41 C END
Page 50
CHAPTER 3 SYSTEM DATA PROGRAMMING Data Assignment for TMF NEAX2000 IVS2 OAI System Manual ND-70922 (E), Issue 1.0 Page 43 DATA ASSIGNMENT FOR TMF DESCRIPTION DATA Assign the OAI function key for starting up TMF to a D term. (1) (2)YY=00 My Line No. + + Key No. F1032-F1047: OAI Function Key No. 0-15 When you start up the TMF by pressing the OAI function key, assign the operation code to the OAI function key assigned by CM90. (1) (2)Y=0 F1032-F1047: OAI Function Key No. 0-15 192-255:...