Page 41

 NEAX2000 IVS2 OAI System ManualPage 34  ND-70922 (E), Issue 1.0
CHAPTER 3  SYSTEM DATA PROGRAMMING
OAI Communication Data Assignment (TCP/IP)
OAI COMMUNICATION DATA ASSIGNMENT (TCP/IP)
NOTE 1:The IP Address must be assigned to the 1st data 00-03 as follows.
IP Address: AAA.BBB.CCC.DDD [AAA-DDD: 2nd Data (2)]
NOTE 2:When setting the 2nd Data as shown in Table 3-2 IP Address Assignment Patterns
(PN-CC01 Card) (See Page 35), note that the setting data is different from the data
actually assigned.
IP...

Page 42

CHAPTER 3  SYSTEM DATA PROGRAMMING
OAI Communication Data Assignment (TCP/IP)
NEAX2000 IVS2 OAI System Manual    
ND-70922 (E), Issue 1.0   Page 35
Table 3-2  IP Address Assignment Patterns (PN-CC01 Card)
PATTERNINPUT DATA (2ND DATA)
ASSIGNED DATA
AAA BBB CCC DDD
When no data 
or all 0 is input
No data No data No data No data4C.A4.XX.XX (HEX)
4C.A4: Fixed
XX.XX: According to the 
switch setting of 
SW1 (D15-D8) 
and SW2 (D7-D0)
(The IP Address is the 
same as lower 32 bits of 
MAC Address.)
0000
When the...

Page 43

 NEAX2000 IVS2 OAI System ManualPage 36  ND-70922 (E), Issue 1.0
CHAPTER 3  SYSTEM DATA PROGRAMMING
OAI Communication Data Assignment (RS-232C)
OAI COMMUNICATION DATA ASSIGNMENT (RS-232C)
DESCRIPTION DATA
Assign the attribute data for RS-232C port 
of the PN-AP01.
(1)
(2)YY=04 Data Transmission Speed of 
RS-232C port
3
0: 150 bps
1: 300 bps
2: 600 bps
3: 1200 bps
4: 2400 bps
5: 4800 bps
6: 9600 bps

(1)
(2)YY=05 Parity Check
3
1  : Ineffective

(1)
(2)YY=06 Synchronous/Asynchronous
3
7  :...

Page 44

CHAPTER 3  SYSTEM DATA PROGRAMMING
OAI Communication Data Assignment (RS-232C)
NEAX2000 IVS2 OAI System Manual    
ND-70922 (E), Issue 1.0   Page 37
DESCRIPTION DATA

(1)
(2)YY=08 Stop Bit
3
1  : 1-Stop Bit

(1)
(2)YY=09 Type of Code
3
06: JIS (8-bit)

(1)
(2)YY=10 Flow Control by DCD Signal
3
0  : Ineffective
1 :Effective

(1)
(2)YY=11 RTS Signal Control
3
0  : Ineffective (RTS Signal ON)
1 :Effective
NOTE:When connecting an external
processor with RS-232C in-
terface via MODEM, assign 0
(RTS Signal...

Page 45

 NEAX2000 IVS2 OAI System ManualPage 38  ND-70922 (E), Issue 1.0
CHAPTER 3  SYSTEM DATA PROGRAMMING
Data Assignment for MSF
DATA ASSIGNMENT FOR MSF
To start up MSF from Dterm by using an OAI function key:
DESCRIPTION DATA
Assign the OAI function key for starting up 
MSF to a D
term.
(1)
(2)YY=00
My Line No. +   + Key No.
F1032-F1047: OAI Function Key 
No. 0-15
When pressing the OAI function key to 
start up MSF, assign the operation code 
to the OAI function key assigned by 
CM90.
(1)
(2)Y=0...

Page 46

CHAPTER 3  SYSTEM DATA PROGRAMMING
Data Assignment for MSF
NEAX2000 IVS2 OAI System Manual    
ND-70922 (E), Issue 1.0   Page 39
To start up MSF from PB Telephone/Dterm by using an access code:
DESCRIPTION DATA
Assign the Service Restriction Class for 
starting up MSF to the required stations.
NOTE:After starting up the MSF from a 
PB telephone or Dterm, the PB re-
ceiver is busy during MSF mode. 
Therefore, you must make sure 
that a call origination is not avail-
able if all PB receivers are used. 
To...

Page 47

 NEAX2000 IVS2 OAI System ManualPage 40  ND-70922 (E), Issue 1.0
CHAPTER 3  SYSTEM DATA PROGRAMMING
Data Assignment for MSF
DESCRIPTION DATA
When sending a message through the 
Digital Announcement Trunk (PN-2DATA) 
to PB telephone/D
term user by using TCF-
D facility:
When sending a tone to PB telephone/
D
term user by using TCF-D facility:
When not sending a message or tone:
A
CMD7
C
B
END 

Page 48

CHAPTER 3  SYSTEM DATA PROGRAMMING
Data Assignment for MSF
NEAX2000 IVS2 OAI System Manual    
ND-70922 (E), Issue 1.0   Page 41
DESCRIPTION DATA
Assign a Digital Announcement Trunk 
card number to the required LEN.
NOTE 1:The Digital Announcement 
Trunk card number must be 
assigned to the first LEN (Level 
0), the third LEN (Level 2), the 
fifth LEN (Level 4) and the 
seven LEN (Level 6) of each LT 
slot.
NOTE 2:EB000 and EB001 are 
dedicated to built-in Digital 
Announcement Trunk of the MP 
card.(1)...

Page 49

 NEAX2000 IVS2 OAI System ManualPage 42  ND-70922 (E), Issue 1.0
CHAPTER 3  SYSTEM DATA PROGRAMMING
Data Assignment for MSF
DESCRIPTION DATA
Specify the tone sending timer in the OAI 
terminal mode, if required.
(1)
(2)Y=0
56
01-99: 0-396 sec. (4 sec. increments)
If no data is set, the default setting is 20-24 
sec.CM41
C
END 

Page 50

CHAPTER 3  SYSTEM DATA PROGRAMMING
Data Assignment for TMF
NEAX2000 IVS2 OAI System Manual    
ND-70922 (E), Issue 1.0   Page 43
DATA ASSIGNMENT FOR TMF
DESCRIPTION DATA
Assign the OAI function key for starting up 
TMF to a D
term.
(1)
(2)YY=00
My Line No. +   + Key No.
F1032-F1047: OAI Function Key 
No. 0-15
When you start up the TMF by pressing 
the OAI function key, assign the operation 
code to the OAI function key assigned by 
CM90.
(1)
(2)Y=0
F1032-F1047: OAI Function Key
No. 0-15
192-255:...
Start reading NEC Neax 2000 Ivs2 Oai System Manual

Related Manuals for NEC Neax 2000 Ivs2 Oai System Manual