NEC Neax 2000 Ivs Wcs System Manual
Here you can view all the pages of manual NEC Neax 2000 Ivs Wcs System Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 151
ND-46248 (E) CHAPTER 4 Pag e 12 9 Revision 2.0 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Specify the Application of answer signal from the distant office for outgoing connection to the trunk route. (1) (2)YY=04 Trunk Route No. (00-63) 1 : Battery Reversal 7 : Answer signal does not arrive from C.O. Line (Answer timing shall be set by CM41Y=0 Function No. 03) Specify the Application of release signal from the distant office for an outgoing connection of an incoming connection to the trunk route....
Page 152
CHAPTER 4 ND-46248 (E) Pag e 13 0 Revision 2.0 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Specify the Sender Prepause Timing to the trunk route. (1) (2)YY=21 Trunk Route No. (00-63) 00: 0 sec. 08: 6.0 sec. 01: 0.5 sec. 09: 7.0 sec. 02: 1.0 sec. 10: 8.0 sec. 03: 1.5 sec. 11: 9.0 sec. 04: 2.0 sec. 12: 10.0 sec. 05: 2.5 sec. 13: 11.0 sec. 06: 4.0 sec. 14: 12.0 sec. 07: 5.0 sec. 15 : 3.0 sec. Note:To reduce the connecting time, shorten the prepause timing (i.e., second data=03 (1.5 sec.)) Specify the DP...
Page 153
ND-46248 (E) CHAPTER 4 Pag e 13 1 Revision 2.0 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Assign the DTMF Signal Width to the trunk route. (1) (2)YY=26 Trunk Route No. (00-63) 0 : 64 ms. 1 : 128 ms. Note:To reduce the connecting time, it is recommended to shorten the DTMF inter-digital Pause timing (YY=24), i.e., second data=2 (80ms). YY=26, i.e., second data=0 (64ms) Assign the Trunk Release by detection of re- versal of tip and ring to the trunk route. (1) (2)YY=39 Trunk Route No. (00-63) 0 : Not to...
Page 154
CHAPTER 4 ND-46248 (E) Pag e 13 2 Revision 2.0 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Specify the CDT card Terminating Impedance. (1) (2)YY= 100 Trunk Route No. (00-63) 0 : 600 Ω/complex BNW for Integrated Type and Adjunct Type(2) 2 : 600 Ω/600 Ω for Adjunct Type(1) (LC-COT) Assign the trunk to be seized on each PS sta- tion basis. (1) (2)YY=16 X-XXXX: PS Station No. D000-D255: Trunk No. Automatic Pause Entry Table Designate digits requiring automatic pause. (1) (2)Y=0 Block Number (00-04)...
Page 155
ND-46248 (E) CHAPTER 4 Pag e 13 3 Revision 2.0 SYSTEM DATA PROGRAMMING 3.6 Service Feature Data Assignment 3.6.1 Announcement Service Refer to Appendix A for the operating procedure. To provide the Announcement Service: DESCRIPTION DATA Assign a Digital Announcement Trunk Circuit No. to the required LEN. Note:The Digital Announcement Trunk Circuit No. must be assigned to the first LEN (Level 0) and/or the third LEN (Level 2) of each LT slot.(1) (2)LEN (0000-0511) EB000-EB127: Digital Announcement Trunk...
Page 156
CHAPTER 4 ND-46248 (E) Pag e 13 4 Revision 2.0 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Specify the message reply timer for the An- nouncement Service when a PS is out of cell/PS power is off. Note:This data is effective only when CM08-086 is set to 0. (1) (2)Y=0 85 01-99: 4-396 sec. in 4 sec. increments If no data is set, the default setting is 8-12 sec- onds. Specify the duration of message for the An- nouncement Service when a PS does not an- swer. (1) (2)Y=0 75 01-99: 4-396 sec. in 4 sec....
Page 157
ND-46248 (E) CHAPTER 4 Pag e 13 5 Revision 2.0 SYSTEM DATA PROGRAMMING To record/replay/delete a message from a station: There are two methods to record/replay/delete a message from a PS or a station, as mentioned below. 1. To record/replay/delete a message from a station or a PS by dialling an access code assigned by CM20, do the following programming. This method is available for only the Integrated Type. DESCRIPTION DATA Assign the Class of Service for the Announcement Service to a certain...
Page 158
CHAPTER 4 ND-46248 (E) Page 136 Addendum-001 Revision 2.1 MARCH, 1999 SYSTEM DATA PROGRAMMING 2. To record/replay/delete a message from a PS by dialing “1”, “2”, “3”, do the following programming. This method is available for both the Integrated Type and the Adjunct Type. DESCRIPTION DATA Assign the Class of Service for the Announce- ment Service to a certain PS/station. Note:By this method, while a PS specified to “Allowed” to record/ replay/delete a message by CM15 YYY=110, the PS cannot originate a...
Page 159
ND-46248 (E) CHAPTER 4 Addendum-001 Page 137 MARCH, 1999 Revision 2.1 SYSTEM DATA PROGRAMMING 3.6.2 Call Forwarding-Not Available DESCRIPTION DATA Assign the destination VMS station for Call Forwarding-Not Available.• (1) (2)YY=20 00-63: Tenant No. of Virtual PS X-XXXX: VMS Station No. Assign the access code to set/cancel Call For- warding when the incoming call is not avail- able, and set the access code to replay the message. Provide the PSII station(s) with Message Waiting Service. Note:This...
Page 160
CHAPTER 4 ND-46248 (E) Pag e 13 8 Revision 2.0 SYSTEM DATA PROGRAMMING 3.6.3 Calling Name Display-PS Refer to the following manuals for the name display feature programming. Feature Programming Manual; Alphanumeric Display, Caller ID Class CCIS System Manual; Calling Name Display-CCIS PMS System Manual; Guest Name Display DESCRIPTION DATA Specify the terminal kind of the PS as “Dterm PS II”. (1) (2)YY=15 X-XXXX: PS Station No. (Assigned by CM1C) 00: D term PS II Specify the kind of the ZT as “D term...