Page 151

ND-46248 (E) CHAPTER 4
Pag e 12 9
Revision 2.0
SYSTEM DATA PROGRAMMING
DESCRIPTION DATA
Specify the Application of answer signal from 
the distant office for outgoing connection to 
the trunk route.
(1)
(2)YY=04
Trunk Route No. (00-63)
1 : Battery Reversal
7 : Answer signal does not arrive from 
C.O. Line (Answer timing shall be set by 
CM41Y=0 Function No. 03)
Specify the Application of release signal from 
the distant office for an outgoing connection 
of an incoming connection to the trunk route....

Page 152

CHAPTER 4 ND-46248 (E)
Pag e 13 0
Revision 2.0
SYSTEM DATA PROGRAMMING
DESCRIPTION DATA
Specify the Sender Prepause Timing to the 
trunk route.
(1)
(2)YY=21
Trunk Route No. (00-63)
00: 0 sec. 08: 6.0 sec.
01: 0.5 sec. 09: 7.0 sec.
02: 1.0 sec. 10: 8.0 sec.
03: 1.5 sec. 11: 9.0 sec.
04: 2.0 sec. 12: 10.0 sec.
05: 2.5 sec. 13: 11.0 sec.
06: 4.0 sec. 14: 12.0 sec.
07: 5.0 sec. 15 : 3.0 sec.
Note:To reduce the connecting time,
shorten the prepause timing
(i.e., second data=03 (1.5
sec.))
Specify the DP...

Page 153

ND-46248 (E) CHAPTER 4
Pag e 13 1
Revision 2.0
SYSTEM DATA PROGRAMMING
DESCRIPTION DATA
Assign the DTMF Signal Width to the trunk 
route.
(1)
(2)YY=26
Trunk Route No. (00-63)
0 : 64 ms.
1 : 128 ms.
Note:To reduce the connecting time,
it is recommended to shorten
the DTMF inter-digital Pause
timing (YY=24), i.e., second
data=2 (80ms). YY=26, i.e.,
second data=0 (64ms)
Assign the Trunk Release by detection of re-
versal of tip and ring to the trunk route.
(1)
(2)YY=39
Trunk Route No. (00-63)
0 : Not to...

Page 154

CHAPTER 4 ND-46248 (E)
Pag e 13 2
Revision 2.0
SYSTEM DATA PROGRAMMING
DESCRIPTION DATA
Specify the CDT card Terminating Impedance.
(1)
(2)YY= 100
Trunk Route No. (00-63)
0 : 600 
Ω/complex BNW for Integrated 
Type and Adjunct Type(2)
2 : 600 
Ω/600 
Ω for Adjunct Type(1) 
(LC-COT)
Assign the trunk to be seized on each PS sta-
tion basis.
(1)
(2)YY=16
X-XXXX: PS Station No.
D000-D255: Trunk No.
Automatic Pause Entry Table
Designate digits requiring automatic pause.
(1)
(2)Y=0
Block Number (00-04)...

Page 155

ND-46248 (E) CHAPTER 4
Pag e 13 3
Revision 2.0
SYSTEM DATA PROGRAMMING
3.6 Service Feature Data Assignment
3.6.1 Announcement Service
Refer to Appendix A for the operating procedure.
To provide the Announcement Service:
DESCRIPTION DATA
Assign a Digital Announcement Trunk Circuit 
No. to the required LEN.
Note:The Digital Announcement Trunk
Circuit No. must be assigned to
the first LEN (Level 0) and/or the
third LEN (Level 2) of each LT
slot.(1)
(2)LEN (0000-0511)
EB000-EB127: Digital Announcement 
Trunk...

Page 156

CHAPTER 4 ND-46248 (E)
Pag e 13 4
Revision 2.0
SYSTEM DATA PROGRAMMING
DESCRIPTION DATA
Specify the message reply timer for the An-
nouncement Service when a PS is out of cell/PS 
power is off.
Note:This data is effective only when
CM08-086 is set to 0.
(1)
(2)Y=0
85
01-99: 4-396 sec. in 4 sec. increments
If no data is set, the default setting is 8-12 sec-
onds.
Specify the duration of message for the An-
nouncement Service when a PS does not an-
swer.
(1)
(2)Y=0
75
01-99: 4-396 sec. in 4 sec....

Page 157

ND-46248 (E) CHAPTER 4
Pag e 13 5
Revision 2.0
SYSTEM DATA PROGRAMMING
To record/replay/delete a message from a station:
There are two methods to record/replay/delete a message from a PS or a station, as mentioned below.
1. To record/replay/delete a message from a station or a PS by dialling an access code assigned by CM20, do
the following programming.
This method is available for only the Integrated Type.
DESCRIPTION DATA
Assign the Class of Service for the 
Announcement Service to a certain...

Page 158

CHAPTER 4 ND-46248 (E)
Page 136 Addendum-001
Revision 2.1 MARCH, 1999
SYSTEM DATA PROGRAMMING
2. To record/replay/delete a message from a PS by dialing “1”, “2”, “3”, do the following programming.
This method is available for both the Integrated Type and the Adjunct Type.
DESCRIPTION DATA
Assign the Class of Service for the Announce-
ment Service to a certain PS/station.
Note:By this method, while a PS
specified to “Allowed” to record/
replay/delete a message by CM15
YYY=110, the PS cannot
originate a...

Page 159

ND-46248 (E) CHAPTER 4
Addendum-001 Page 137
MARCH, 1999 Revision 2.1
SYSTEM DATA PROGRAMMING
3.6.2 Call Forwarding-Not Available
DESCRIPTION DATA
Assign the destination VMS station for Call 
Forwarding-Not Available.•
(1)
(2)YY=20
00-63: Tenant No. of Virtual PS
X-XXXX: VMS Station No.
Assign the access code to set/cancel Call For-
warding when the incoming call is not avail-
able, and set the access code to replay the 
message.
Provide the PSII station(s) with Message 
Waiting Service.
Note:This...

Page 160

CHAPTER 4 ND-46248 (E)
Pag e 13 8
Revision 2.0
SYSTEM DATA PROGRAMMING
3.6.3 Calling Name Display-PS
Refer to the following manuals for the name display feature programming.
Feature Programming Manual; Alphanumeric Display, Caller ID Class
CCIS System Manual; Calling Name Display-CCIS
PMS System Manual; Guest Name Display
DESCRIPTION DATA
Specify the terminal kind of the PS as “Dterm 
PS II”.
(1)
(2)YY=15
X-XXXX: PS Station No. (Assigned by 
CM1C)
00: D
term PS II
Specify the kind of the ZT as “D
term...
Start reading NEC Neax 2000 Ivs Wcs System Manual