ND-46248 (E) CHAPTER 4 Addendum-001 Page 157 MARCH, 1999 Revision 2.1 SYSTEM DATA PROGRAMMING 3.7.4 Visitor PS Data Assignment DESCRIPTION DATA Execute System Data Memory All Clear of the DBM (AP00) card. The System Data Memory All Clear must be done at the initial setup. This data is valid when the DBM card is on- line.• (1) (2)YYY=999 1 (All Clear) CCC Execute Work Memory All Clear of the DBM card. The Work Memory All Clear must be done be- fore the system starts operating. All HLR, VLR data is cleared...
Page 182
CHAPTER 4 ND-46248 (E) Page 158 Addendum-001 Revision 2.1 MARCH, 1999 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Assign the Trunk Route to be used for request- ing the data of the Visitor PS against its Home PBX. This data is valid when the DBM card is on- line. (1) (2)YYY=100-107 (Route Selection Pattern No. 00-07) 1-4: First-Fourth Selected Route 00-63: Q931a D Channel Trunk Route No. NONE : No Data CCC: No Data Clear Assign the Default restriction class for Visitor PS. Note:This data must be...
Page 183
ND-46248 (E) CHAPTER 4 Pag e 15 9 Revision 2.0 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Specify the telephone set type of Virtual LC for the Visitor PS as 10 PPS. (1) (2)YY=00 X-XXXX: Virtual LC Station No. 1: 10 PPS Assign the Service Restriction Class of the Virtual LC for the Visitor PS. Assign the different class to the Virtual LC for Visitor PSs from the station and Home PS of the PBX. (1) (2)YY=02 X-XXXX: Virtual LC Station No. XXYY XX: Service Restriction Class A (00-15 ) YY: Service...
Page 184
CHAPTER 4 ND-46248 (E) Pag e 16 0 Revision 2.0 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Assign a Trunk Route to each trunk number used for Virtual COT for the Visitor PS. Make a separate route from other trunk routes. (1) (2)YY=00 Trunk No. (000-255) Trunk Route No. (00-63) Assign the terminating system to the Virtual COT as “Roaming Termination”. (1) (2)YY=02 (Day Mode) YY=03 (Night Mode) Trunk No. (000-255) 22: Roaming Termination Assign trunk route data to the Virtual COT route number for the...
Page 185
ND-46248 (E) CHAPTER 4 Addendum-001 Page 161 MARCH, 1999 Revision 2.1 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Specify the Route Selection Pattern Number as “Pattern Number 0”, for all classes of the Trunk Restriction Class (01-06) sent from the Home PBX. This data is valid when the DBM card is on- line. (1) (2)YYY=208 01-06: Trunk Restriction Class sent from the Home PBX 00: Route Selection Pattern 0 Specify the Virtual COT Trunk route to be used for originating/terminating calls from/to the...
Page 186
CHAPTER 4 ND-46248 (E) Pag e 16 2 Revision 2.0 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Provide the Visitor PS with the capability to enter an Account Code, if required. (1) (2)YY=30 00-15 (Service Restriction Class A assigned by CM12 YY=02) 0: Restricted 1 : Allowed Specify the maximum number of Account Code.(1) (2)10 (Max. Digits for Account Code) 01-16 : 01-16 digitsCM15 E CM42 END
Page 187
ND-46248 (E) CHAPTER 4 Pag e 16 3 Revision 2.0 SYSTEM DATA PROGRAMMING 3.8 Maintenance Data Assignment DESCRIPTION DATA Assign the registration of fault information into Memory and the control of the external alarm. (1) (2)Y=2 12: ZT fault occurred (Not recovered) 2B: ZT fault occurred 3B: ZT fault recovered 0: Registration of Fault Memory/No out- put of External alarm 1: Registration of Fault Memory /External alarm is MN alarm 2: Registration of Fault Memory /External alarm is MJ alarm NONE :...
Page 188
CHAPTER 4 ND-46248 (E) Pag e 16 4 Revision 2.0 SYSTEM DATA PROGRAMMING 3.9 Maintenance Administration Terminal (MAT) The figures below describe the installation for the WCS Maintenance Administration Terminal (MAT). For more information about system-required equipment, system description and MAT Operation, refer to your MAT Operation Guide. 3.9.1 Direct Connection Figure 4-1 Cable Connection (Direct) Table 4-1 MAT Cable (Direct) DESCRIPTION QUANTITY REMARKS MAT CA-Q 1/Sys RS-232C Cable, 13.1 ft. (4.0...
Page 189
ND-46248 (E) CHAPTER 4 Pag e 16 5 Revision 2.0 SYSTEM DATA PROGRAMMING 3.9.2 Remote Connection Remote connection is available via an internal modem in the MP or an external modem. Remote Connection via Internal Modem Figure 4-2 MAT Cable Connection (Remote Connection via Internal Modem) Note 1: The Installation Cable is connected to LTC0, LTC1, or LTC2 connector depending on the installed loc- tion of the COT card. Note 2:The MP to COT connection is made through internal switching of the Time...
Page 190
CHAPTER 4 ND-46248 (E) Pag e 16 6 Revision 2.0 SYSTEM DATA PROGRAMMING 4. DATA PROGRAMMING SHEETS This section provides the sheets of WCS data, on a command basis. Complete the blank with data assigned. The following symbol with the meaning indicated below is used within the data sheets. : System Initialization After data setting, system initialization is required by the SW1 switch on the MP card. INITIAL