Page 111

ND-46248 (E) CHAPTER 3Page 91
Revision 2.0
INSTALLATION
Figure 3-43    Battery Connection in BATTM for PW86 Card
STEP 2: Plug the battery cable connector into the BATT1 connector on the PW86 card in PIM0 or PIM4 as sh ow n in  Fi gure  3 -44 .
Figure 3-44    Connection to PW86 Card
TO PW86 CARD IN 
PIM0/PIM4
BATTERY CABLE
BATTM
Note:External batteries can be connected in the same manner as the batteries in the BATTM.
Blue Black Red
24 V DC
BATTERY CABLE
PW86 CARDBATT1 CONNECTOR
PIM0/PIM4 

Page 112

CHAPTER 3 ND-46248 (E) 
Pag e 92
Revision 2.0
INSTALLATION
STEP 3: When the system is a multiple-PIM configuration, connect the PW86 cards to each other using thePWR CA-A  as s h ow n in  Fig ure  3- 45 .
Figure 3-45    Connection of PWR CA-A for a Multiple PIM Configuration
BATT2 
BATT1
PW86
PIM3
BATT2 
BATT1
PW86
PIM2
BATT2 
BATT1
PW86
PIM1
BATT2 
BATT1
PW86PIM0
BATTERY CABLE
BATT2 
BATT1
PW86
PIM7
BATT2 
BATT1
PW86
PIM6
BATT2 
BATT1
PW86
PIM5
BATT2 
BATT1
PW86PIM4
BATTERY CABLE
Note:External batteries...

Page 113

ND-46248 (E) CHAPTER 3Page 93
Revision 2.0
INSTALLATION
2. For PW91 card (-48 V DC) 
STEP 1: Connect the battery cables to the batteries, and mount the battery units (4x12 VDC, 24AH per unit) in to t he Ba tt e ry  M odule  ( B ATTM)  as sh ow n  in  Figure  3 -46  and 3 -47 .
Figure 3-46    Battery Mounting into BATTM for PW91 Card
BATTERY CABLE
BATTM
BATTERY UNIT (2x12 V DC, 24AH)
BATTERY UNIT (2x12 V DC, 24AH)
FRONT
Recommended Batteries
GS Portalac PE12V 24ABI 
Yuasa NP24-12B
Specifications UL...

Page 114

CHAPTER 3 ND-46248 (E) 
Pag e 94
Revision 2.0
Figure 3-47    Battery Connection in BATTM for PW91 Card
STEP 2: Plug the battery cable connector into the BATT2 connector on the PW91 card in the PWRM assh ow n in  Fi gure  3 -48 .
Figure 3-48    Connection to PW91 Card
TO PW91 CARD IN PWRM
BATTERY CABLE
BATTM
Note:External batteries can be connected in the same manner as the batteries in the BATTM.
-48 V DC
Red
Blue
BATTERY CABLE
PW91 CARD
BATT2 CONNECTOR
PWRM 

Page 115

ND-46248 (E) CHAPTER 3Page 95
Revision 2.0
INSTALLATION
STEP 3: When the system is equipped with more than two PW91 cards, connect the PW91 cards to each other usin g t he P WR CA-A  as s how n in  Fig ure  3-49 .
Figure 3-49    Connection of PWR CA-A/BATTERY CABLE
PWRM
PW91
BATT2 
BATT1PW91
BATT2 
BATT1PW91
BATT2 
BATT1PW91
BATT2 
BATT1
TO BATTERYTO BATTERYPWR CA-APWR CA-A 

Page 116

CHAPTER 3 ND-46248 (E) 
Pag e 96
Revision 2.0
INSTALLATION
5. INSTALLATION FOR MULTI-SITE ROAMING
5.1 Installation Procedure for Multi-Site Roaming
Perform  th e  in sta lla ti on  pr oce dure  sh ow n in  Fi gure  3- 50 .
Figure 3-50    Installation Procedure for Multi-Site Roaming
END
START
MOUNTING DTI, DCH AND DBM CARD
SELECTION OF PLO IN MP CARD
CABLE CONNECTION VIA MDF SEE SECTION 5.2 
SEE SECTION 5.3 
SEE SECTION 5.5
MOUNTING PLO CARD
SEE SECTION 5.4 
Note
Note:PLO card (PN-CK00) is required when...

Page 117

ND-46248 (E) CHAPTER 3Page 97
Revision 2.0
INSTALLATION
5.2 Mounting DTI, DCH and DBM Card
STEP 1: On the DTI (PN-24DTA-A/30DTC/30DTC-A) card, DCH (PN-SC01) card and DBM (PN-AP00) car d, s et  the  sw itch es  as  sh ow n in  Fig ure s 3 -51  th rough  3- 53.
Figure 3-51    Switch Settings on DTI Card (1 of 2)
SEE  Note.
JPSJPR1
JPR0 MB
SW
CRC
PCM FRM
AIS [RMT] 
RMT [AIS] BLOFF
ON
8
 
7 
6 
5 
4 
3 
2 
1
JPS
JPR0
SENS RUN
SW MB
SET THE KNOB TO MATCH THE  
AP NO. (04-15) TO BE SET BY 
CM05.
: POSITION TO...

Page 118

CHAPTER 3 ND-46248 (E)
Pag e 98
Revision 2.0
INSTALLATION
Figure 3-51  Switch Settings on DTI Card (2 of 2)
LINE IMPEDANCE:
RIGHT :  75 OHMS (FOR COAXIAL CABLE)
LEFT :  120 OHMS (FOR TWISTED-PAIR CABLE)
JP
MB
UP
SENS
RUN
MB
SW
PCM
FRM
FMRM
RMT
MRMT
AIS
SW
ONOFF
SET THE KNOB TO MATCH THE 
AP NO. (04-15) TO BE SET BY 
CM05.SENS
: POSITION 
TO BE SET
8
7
6
5
1 2 3 4
SEE 
Note.
: POSITION TO BE SET
JPS
BALANCED TRANSMISSION
(FOR TWISTED-PAIR CABLE)
TA GROUNDING ON THE TRANSMIT 
LINE IS PROVIDED
(FOR COAXIAL...

Page 119

ND-46248 (E) CHAPTER 3
Page 99
Revision 2.0
INSTALLATION
Note:
When only one DTI is provided, the clock signals are supplied to the PLO through DTI 0. The DTI 0
card must be mounted in PIM 0 and the SW settings are:
.
When multiple number of DTIs are provided, the system can supply the clock signals from DTI 0 or DTI
1. The system is synchronized to the DTI 0 clock signals normally, and if the DTI 0 clock supply route
is failed, the DTI 1 takes over. Both DTI 0 and DTI 1 cards must be mounted in PIM 0....

Page 120

CHAPTER 3 ND-46248 (E)
Pag e 10 0
Revision 2.0
INSTALLATION
Figure 3-52    Switch Settings on DCH Card
MB
UP
SW0
ONOFF
SET THE KNOB TO MATCH 
THE AP NO. (04-15) TO BE SET 
BY CM05.SENS
: POSITION TO BE SET 4
: POSITION TO BE SET.
3
1
12345678 ON
SW1
SENS
RUN
MB
SW0
LC
LPB
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
ON
OFF: NORTHERN TELECOM INTERFACE
: AT&T INTERFACE
2 
Start reading NEC Neax 2000 Ivs Wcs System Manual