Page 81

ND-46248 (E) CHAPTER 3
Page 61
Revision 2.0
INSTALLATION
The figure in the SWITCH NAME column and the position in    in the SETTING POSITION column
indicate the standard setting of the switch. When the switch is not set as shown by the figure and   , the
setting of the switch varies with the system concerned.
Note 1:Set the groove on the switch knob to the intended switch position.
Note 2:When the power is on flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
Table 3-7...

Page 82

CHAPTER 3 ND-46248 (E)
Pag e 62
Revision 2.0
INSTALLATION
Table 3-8  Lamp Indications on CSH Card
LAMP NAME COLOR FUNCTION
RUN Green Flashes at 120 IPM while the card is operating normally.
DOPE7 Green Lights when No.7 circuit D channel link is connected.
DOPE6 Green Lights when No.6 circuit D channel link is connected.
DOPE5 Green Lights when No.5 circuit D channel link is connected.
DOPE4 Green Lights when No.4 circuit D channel link is connected.
DOPE3 Green Lights when No.3 circuit D channel link is...

Page 83

ND-46248 (E) CHAPTER 3Page 63
Revision 2.0
INSTALLATION
4.6.4 Switch Settings of CSI Card
On  the  CSI  ca rd, s et  th e  swi tc h es  as s hown  in  Figu re 3 -28  and  Tab le 3 -9 .
T able  3 -10  s hows  lamp  ind ic ations  on  the CSI  c ard .
Figure 3-28    Locations of Switches and Lamps on CSI Card
B03B02 
B01 
B00
OPE 
LB 
B13
B12 
B11 
B10 
DL1 
DL0 

Page 84

CHAPTER 3 ND-46248 (E)
Pag e 64
Revision 2.0
INSTALLATION
The figure in the SWITCH NAME column and the position in    in the SETTING POSITION column
indicate the standard setting of the switch. When the switch is not set as shown by the figure and   , the
setting of the switch varies with the system concerned.
Note:Set the groove on the switch knob to the intended switch position.
Table 3-9  Switch Settings on CSI Card
SWITCH NAMESWITCH
NUMBERSETTING
POSITIONFUNCTION CHECK
DL0 (Rotary SW)
Note
0 ~ FFor...

Page 85

ND-46248 (E) CHAPTER 3
Page 65
Revision 2.0
INSTALLATION
Table 3-10  Lamp Indications on CSI Card
LAMP NAME COLOR FUNCTION
OPE Green Lights when the corresponding circuit is in use.
LB Red Lights when a loop-back is in progress.
B13 Red Not used (Flash [60IPM])
B12 RedB channel status
ON  : B2 channel of the No. 1 circuit is in use.
OFF : B2 channel of the No. 1 circuit is in idle.
Flash (60 IPM)  : ZT is not connected to the No. 1 circuit.
ZT is in make-busy status.
B11 RedB channel status
ON  : B1...

Page 86

CHAPTER 3 ND-46248 (E)
Pag e 66
Revision 2.0
INSTALLATION
B03 Red Not used (Flash [60 IPM])
B02 RedB channel status
ON  : B2 channel of the No. 0 circuit is in use.
OFF  : B2 channel of the No. 0 circuit is in idle.
Flash (60 IPM)  : ZT is not connected to the No. 0 circuit.
ZT is in make-busy status.
B01 RedB channel status
ON  : B1 channel of the No. 0 circuit is in use.
OFF  : B1 channel of the No. 0 circuit is in idle.
Flash (60 IPM)  : ZT is not connected to the No. 0 circuit.
ZT is in make-busy...

Page 87

ND-46248 (E) CHAPTER 3
Page 67
Revision 2.0
INSTALLATION
4.7 Mounting FP Card
Mount one FP (PN-CP01) card in the FP slot of PIM0 in any configuration. When the system is equipped with
more than two PIMs – depending on the number of additional PIMs used – mount one FP card in the FP slot of
PIM0 and one FP card in the MP/FP slot of PIM2, PIM4 and PIM6.
Figure 3-29    MP/FP Card Mounting Slots
PIM3PIM7
PIM2PIM6F
PF
P
PIM1PIM5
PIM0PIM4F
PM
PF
P 

Page 88

CHAPTER 3 ND-46248 (E) 
Pag e 68
Revision 2.0
INSTALLATION4.8 Mounting CSI Card
Mount the CSI card in the LT slots of PIM0 through PIM7.
Figure 3-30    Mounting Location of CSI Card (1 of 3)
Note:  
The  m aximum  number  o f f o ur P IM s c an be p owe re d  b y P W 91. ( Fig u re 3 -15 ). If  a  CSI  ca rd  i s  r e m ount ed
in a PIM that is not powered by PW91, an external AC/DC adapter can be used to power the ZT. A max- 
imum of 16 cards can be used; however, this number cannot be exceeded.)...

Page 89

ND-46248 (E) CHAPTER 3
Page 69
Revision 2.0
INSTALLATION
Figure 3-30  Mounting Location of CSI Card (2 of 3)
Note:
When mounting 8 circuits LT card with cabling in the LT08 slot, the CSI card cannot be mounted in the
LT09 slot.
CSI 
CARD
BUILT-IN BATTERY
Mount the CSI card in the LT slots (LT00-LT09).
PIM
P
W
R
LT00LT01LT02LT03LT04LT05LT06/AP0LT07/AP1LT08/AP2LT09/AP3LT10/AP4
AP5MP
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
 Small Platform System 

Page 90

CHAPTER 3 ND-46248 (E)
Pag e 70
Revision 2.0
INSTALLATION
Figure 3-30  Mounting Location of CSI Card (3 of 3)
CSI 
CARD
BUILT-IN BATTERY
Mount the CSI card in the LT slots (LT01-LT08).
PIM
P
W
R
LT00LT01LT02LT03LT04/AP0LT05/AP1LT06/AP2LT07/AP3 LT08/AP4MP
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
 NEAX1000 IVS 
Start reading NEC Neax 2000 Ivs Wcs System Manual

Related Manuals for NEC Neax 2000 Ivs Wcs System Manual