NDA-24219 CHAPTER 3 Page 67 Revision 2.0 NAP-200-007 Sheet 18/55 Termination of Cables on MDF (b) Long Line (PN-AUCA) (see Figure 007-11) Figure 007-11 MDF Cross Connection for Single Line Telephone (Long Line) 29294 428 283 327 2726 26 2 1 LEN0000 LEN0001MDF 1 2 PIM0 P PN-AUCA LT01LTC0 J T1 R1 T0 R0 LEN0000 (No. 0) LEN0001 (No. 1) TO SINGLE LINE TELEPHONE (FOR LONG LINE) 1R026T0 2R127T1 328 429 (P) 26 T0 1 R0 27 T1 2 R1 28 3 29 4 LTC0 (J) Note 1:The PN-AUCA card can also be used as a DID Trunk card. Note 2:For the cross connection for the Power Failure Transfer (PFT), see item (12) in this NAP. TO SINGLE LINE TELEPHONE (FOR LONG LINE)
CHAPTER 3 NDA-24219 Page 68 Revision 2.0 NAP-200-007 Sheet 19/55 Termination of Cables on MDF (5) Multiline Terminal/DSS Console (a) Standard Line (PN-8DLC) (see Figure 007-12) Figure 007-12 MDF Cross Connection for Multiline Terminal/DSS Console (Standard Line) MODULAR TERMINAL TO MULTILINE TERMINAL / DSS CONSOLE 33T7338 R7832 T6327 R6727 T12726 T026 2 1 MDF R01 R12 LEN0000 (No. 0) PIM0 P PN-8DLC LT01LTC0 J LEN0001 (No. 1) LEN0006 (No. 6) LEN0007 (No. 7) • • •• • •• • •• • • 1R026T0 2R127T1 7R632T6 8R733T7 (P) 26 T0 1 R0 27 T1 2 R1 32 T6 7 R6 33 T7 8 R7LEN0000 LEN0001 LEN0006 LEN0007 LTC0 (J) • • •• • •• • •• • •• • •• • •• • •• • • • • • Note:The same connection is required when using PN-4DLCD.
NDA-24219 CHAPTER 3 Page 69 Revision 2.0 NAP-200-007 Sheet 20/55 Termination of Cables on MDF (b) Long Line (PN-2DLCB/N) (see Figure 007-13) Figure 007-13 MDF Cross Connection for Multiline Terminal/DSS Console (Long Line) 29294 428 283 327 2726 26 2 1 1R029T0 2R128T1 327 426 (P) 26 T0 1 R0 27 T1 2 R1 28 3 29 4LEN0000 LEN0001 LTC0 (J)MDF 1 2 MODULAR TERMINAL PIM0 P PN-2DLCB/N LT01LTC0 J T1 T0 R0 R1 LEN0000 (No. 0) LEN0001 (No. 1) TO MULTILINE TERMINAL / DSS CONSOLE
CHAPTER 3 NDA-24219 Page 70 Revision 2.0 NAP-200-007 Sheet 21/55 Termination of Cables on MDF (6) SN610- ATTCON (a) Installation of SN610 ATTCON STEP 1:Screw the handset support onto the bottom of the console as shown in Figure 007-14. Figure 007-14 Mounting Handset Support to SN610 ATTCON HANDSET SUPPORT SN610 ATTCON
NDA-24219 CHAPTER 3 Page 71 Revision 2.0 NAP-200-007 Sheet 22/55 Termination of Cables on MDF STEP 2: To provide the console with the headset in place of the handset, unplug the modular cord from the hand- set and then plug the modular cord to the jack set as shown in Figure 007-15. Figure 007-15 Jack Set Installation for SN610 ATTCON SN610 ATTCON MODULAR CORD JACK SET
CHAPTER 3 NDA-24219 Page 72 Revision 2.0 NAP-200-007 Sheet 23/55 Termination of Cables on MDF STEP 3: Set the switch located inside the console according to the type of headset/handset connected. Refer to Figure 007-16. Figure 007-16 SN610 ATTCON Switch Setting • Slide the directory out of the way. Then insert a flat screw driver’s blade into the notched opening and apply light upward pressure until the access panel is clear of the front lip. At the same time apply pressure (toward you) at the rear of the pedestal to move the access panel. ACCESS PANEL DIRECTORY
NDA-24219 CHAPTER 3 Page 73 Revision 2.0 NAP-200-007 Sheet 24/55 Termination of Cables on MDF Figure 007-16 SN610 ATTCON Switch Setting (Continued) D S C SWITCH • Set the switch according to the type of headset/handset connected. C: Carbon Type Handset/Headset S: SUPRA Headset D: D term Type Handset • Replace the directory and access panel.
CHAPTER 3 NDA-24219 NAP-200-007 Plug the line cor d into the mo dular jack l ocated at the bottom of t he c onsole as sh ow n in Figure 006-16 . LINE CORD P B X
NDA-24219 CHAPTER 3 Page 75 Revision 2.0 NAP-200-007 Sheet 26/55 Termination of Cables on MDF (b) MDF Cross Connection (see Figure 007-18) Figure 007-18 MDF Cross Connection for SN610 ATTCON 29294 428 283 327 2726 26 2 1 1 TA0 26 RA0 2 TB0 27 RB0 3 TA1 28 RA1 4 TB1 29 RB1 (P) 26 RA0 1 TA0 27 RB0 2 TB0 28 RA1 3 TA1 29 RB1 4 TB1LEN0000 LEN0001 LTC0 (J)MDF 1 2 MODULAR TERMINAL PIM0 P PN-2DLCC LT01LTC0 J RB1 TB1 RA1 TA1 RB0 RA0 TA0 TB0LEN0000 (No. 0) LEN0001 (No. 1) TO SN610 ATTCONRED GREEN YELLOW BLACK
CHAPTER 3 NDA-24219 Page 76 Revision 2.0 NAP-200-007 Sheet 27/55 Termination of Cables on MDF (7) Day/Night Mode Change by External Key (see Figure 007-19) Figure 007-19 MDF Cross Connection for Day/Night Mode Change by External Key 29K7294 K6428 K5283 K4327 K32726 K126 2 1 1 K026K1 2 K227K3 3 K428K5 4 K629K7 (P) 26K11K0 27K32K2 28K53K4 29K74K6LEN0000 LEN0002 LTC0 (J)MDF K01 K22LEN0000 PIM0 P PN-DK00 LT01LTC0 J LEN0002 K7 K6 K5 K4 K3 K1 K2 K0 TO KEYS