    							 NDA-24219 CHAPTER 3
    Page 97
    Revision 2.0
    NAP-200-007
    Sheet 48/55
    Termination of Cables on MDF
    Figure 007-36  MDF Cross Connection for PFT (PZ-8PFTA) (Continued)
    3 LTC0 CONNECTOR
    2 PFT1 CONNECTOR
    24 49 E
    25 50 –27V49 E 24
    50 –27V 25
    PFT1 (J)
    26 Sta. T0 1 Sta. R0
    27 4LC. T0 2 4LC. R0
    28 C.O. T0 3 C.O. R0
    29 4COT. T0 4 4COT. R0 1 Sta. R0 26 Sta. T0
    2 4LC. R0 27 4LC. T0
    3 C.O. R0 28 C.O. T0
    4 4COT. R0 29 4COT. T0 
    (P)
    TO STATION
    TO PN-4LC
    TO C.O. LINE
    TO PN-4COT
    PFT0 (J)
    (P)
    1 PFT0 CONNECTOR
    TO PZ-PW86/PZ-PW112
    26 T0 1 R0
    27 2
    28 3
    29 4
    LTC0 (J)
    LEN0000
    LEN0008
    1R026T0
    227
    328
    429
    (P)
    TO PZ-8PFTA
    TO PZ-8PFTA34 T0 9 R0
    35 10
    36 11
    37 129R034T0
    10 35
    11 36
    12 37 
    						
    							CHAPTER 3 NDA-24219  
    Page 98
    Revision 2.0
    NAP-200-007
    Sheet 49/55
    Termination of Cables on MDF
    (13) Alarm Display Panel
    Figure 007-37 shows the cross connection for an Alarm Display Panel.
    Figure 007-37  MDF Cross Connection for Alarm Display Panel
    REAR
    ALARM DISPLAY PANEL
    26 1
    50 MN 25 MJ
    LTC0 (J)
    126
    25 MJ 50 MN
    (P)
    PWRMJMIN
    FRONT25
    5025
    50MJ
    MN
    –27V
    GPN-CP03PIM0 MDF
    LTC0
    P J
    PZ-PW86/PZ-PW112 
    						
    							 NDA-24219 CHAPTER 3
    Page 99
    Revision 2.0
    NAP-200-007
    Sheet 50/55
    Termination of Cables on MDF
    (14) SN716 DESKCON
    (a) Installation of SN716 DESKCON (see Figure 007-38)
    STEP 1:Unpack and assemble SN716 DESKCON.
    Figure 007-38  Assembly of SN716 DESKCON
    (0*%9 75.6/ &DOO 3DFN 6&69& /1
    7,(%XV\ $71 1$16 5HFDOO
    
     
      
    
    3$* (
    5(&
    6WDUW
    0XWH1LJKW
    3RVLWLRQ %XV\
    9ROXPH
    (67
    $QVZHU
    
     (67 &DQFHO
    
    7D O N
    
    +ROG
     
    5HOHDVH
    65& 
    
    
    
    
    
    / 
    / 
    / 
    / 
    / 
    /  
    						
    							CHAPTER 3 NDA-24219  
    Page 100
    Revision 2.0
    NAP-200-007
    Sheet 51/55
    Termination of Cables on MDF
    STEP 2:
    Plug the line cord from the modular jack into the modular jack located on the bottom of the DESKCON,
    labeled “Line”. This interface is a 6 conductor (3 pair), modular jack. The inner 1 pair is for signal and
    the outer 2 pairs are for power supply (when connected via PN-PW00). See Figure 007-39.
    Figure 007-39  SN716 DESKCON Cable Connection
    BOTTOM VIEW OF DESKCON
    24 VDC
    H/S 0
    For Handset or Headset
    H/S 1
    For Handset or Headset Page Rec Line
    PN-4DLC
    PN-8DLC
    SN716 DESKCON
    MODULAR
    TERMINALMDFNEAX1000 IVS
    -24 AC Adapter
    DESKCON - AC ADAPTER POWER OPTION
    PN-4DLC
    PN-8DLC MODULAR
    TERMINALMDFNEAX1000 IVS1P
    DESKCON - PN-PW00 POWER OPTION
    PN-4DLC
    PN-8DLC2P
    3P3P
    3P1P1P
    SN716 DESKCON 
    						
    							 NDA-24219 CHAPTER 3
    Page 101
    Revision 2.0
    NAP-200-007
    Sheet 52/55
    Termination of Cables on MDF
    (b) MDF Cross Connection with AC Adapter Power Option (see Figure 007-40)
    Figure 007-40  MDF Cross Connection with AC Adapter Power Option
    26 Bx 1 Ax
    LTC0 (J)
    1Ax26Bx
    (P)
    LEN0000
    MDF
    LEN0000
    Ax
    Bx
    Ax
    Bx
    PN-8DLCPIM0
    1
    26
    1
    2
    3
    4
    5
    6
    MODULAR
    TERMINAL
    -24 AC Adapter
    to Commercial
    AC Outlet
    SN716 DESKCON 
    						
    							CHAPTER 3 NDA-24219  
    Page 102
    Revision 2.0
    NAP-200-007
    Sheet 53/55
    Termination of Cables on MDF
    (c) MDF Cross Connection via PN-PW00 Power Option (see Figure 007-41)
    Figure 007-41  MDF Cross Connection via PN-PW00 Power Option
    26 Bx 1 Ax
    LTC0 (J)
    1Ax26Bx
    (P)
    LEN0000
    1 Grd 26 -48V
    2 Grd 27 -48V
    (P)
    MDF
    LEN0000
    Ax
    Bx
    Ax
    Bx
    PN-8DLCPIM0
    1
    26
    1
    2
    3
    4
    5
    6
    MODULAR
    TERMINALPW00
    Grd
    -48V
    Grd
    -48V
    SN716 DESKCON 
    						
    							 NDA-24219 CHAPTER 3
    Pag e 1 03
    Revision 2.0
    NAP-200-007
    Sheet 54/55
    Termination of Cables on MDF
    (15) Single Line Device Interface - Recommended Method
    The NEAX1000 does not provide Ring Generator Voltage or Message Waiting light supply. An external
    Ring Generator may be installed, but there is no connector for interfacing a Message Waiting power supply.
    It is therefore recommended that single line devices be interfaced to the system via Analog Port Adapters
    with Ring, which are operating in Dual Port Mode. See Figure 007-42. When provided with optional 
    external Ring Generator, ensure that connection to output terminals of Ring Generator are in accordance
    with National Electrical Code. Ring Generator shall be a UL-listed type.
    Figure 007-42  Single Line Device Interface
    NoteLT
    08MP
    P
    W
    R
    8
    D
    L
    C
    Dterm
    APRSINGLE LINE DEVICE
    APR in Dual Port Mode
    for Single Line Interface
    Note:When upper 4LENs of 8DLC, mounted in LT08, is used for Dual Port Mode Extension Assignment,
    no system ports are lost. The lower 4 LENs of Virtual Slot LT09 are used for Station Assignment of
    Analog Port Adapter Station.
    0051
    0050
    0049
    0048VIRTUAL SLOT LT09LEN to be used for 
    station assignment 
    of station connected 
    to APR 
    						
    							CHAPTER 3 NDA-24219  
    Page 104
    Revision 2.0
    NAP-200-007
    Sheet 55/55
    Termination of Cables on MDF
    (16) Message Center Interface Connection for VM00 to AP00 (see Figure 007-43)
    Figure 007-43  Message Center Interface Connection for VM00 to AP00
    Note08 09
    P
    W
    R 8
    D
    L
    C
    Dterm
    APR
    APR in Dual Port Mode
    for Single Line Interface
    Note:For Dual Port Mode, assign upper 4 LENs of 8DLCJ in LT08 and lower 4 LENs in Virtual Slot for
    APR Extension.
    VIRTUAL SLOT
    J 07 06
    050403020100
    A
    P
    0
    0 8
    C
    O
    T
    M 8
    D
    L
    C
    J 8
    D
    L
    C
    J 8
    D
    L
    C
    JC
    P
    0
    3
    COM 2
    COM 1 PN-VM00
    AD-8
    Voice MailMP
    Note*
    *
    *
    *
    AP VM-0.7 CA-A
    LTC 1
    PIM ABA-UA
    25 T0 50 R0to Internal Modem of VM
    Connection to Internal
    Modem of AD-8 Voice Mail
    Maintenance Console
    25 PIN D-SUB
    CONNECTOR
    CUSTOMER
    PROVIDED
    CABLE
    RS RVS4S CA
    or MAT CA-P
    for Voice Mail 
    						
    							 NDA-24219 CHAPTER 3
    Page 105
    Revision 2.0
    NAP-200-008
    Sheet 1/10
    Switch Setting of Circuit Card
    1. CIRCUIT CARDS SWITCH SETTING
    Table 008-1 shows the control circuit cards and Table 008-2 shows the line/trunk circuit cards. This NAP provides
    information on each of these cards. As for the other circuit cards, refer to the Circuit Card Manual.
    Table 008-1  Control Circuit Cards
    NAME
    (FUNCTIONAL 
    NAME)EXISTENCE OF 
    LAMPS
    X: PROVIDED
    —: NOT PROVIDEDEXISTENCE OF 
    SWITCHES
    X: PROVIDED
    —: NOT PROVIDEDEXTRACTION/INSERTION 
    WITH POWER ON
    X: ALLOWED
    —: NOT ALLOWED
    PN-CP03 (MP) X X —
    PZ-PW86 (PWR) X X —
    PZ-PW112 (PWR) X X —
    Table 008-2  Line/Trunk Circuit Cards
    NAME
    (FUNCTIONAL 
    NAME)EXISTENCE OF 
    LAMPS
    X: PROVIDED
    —: NOT PROVIDEDEXISTENCE OF 
    SWITCHES
    X: PROVIDED
    —: NOT PROVIDEDEXTRACTION/INSERTION 
    WITH POWER ON
    X: ALLOWED
    —: NOT ALLOWED
    PN-8DLC (DLC) X — X
    PN-8COT (COT) X — X 
    						
    							CHAPTER 3 NDA-24219  
    Page 106
    Revision 2.0
    NAP-200-008
    Sheet 2/10
    Switch Setting of Circuit Card
    2. PN-CP03 (MP)
    (1) Locations of Lamps, Switches, and Connectors (see Figure 008-1)
    Figure 008-1  PN-CP03 (MP) Card
    (2) Lamp Indications (see Table 008-3)
    Table 008-3  PN-CP03 (MP) Card Lamp Indications
    LAMP NAME COLOR FUNCTION
    RUN Green Flashes at 120 IPM while the circuit card is operating normally.
    CLKIN Green Lights while receiving clock signals to the PLO oscillator.
    SW3
    RUN
    SW1
    SW2
    CLK
    JP0
    RS1
    JACK
    VR
    RS0
    JP1 
    						
    All NEC manuals Comments (0)