    							 NDA-24219 CHAPTER 3
    Page 47
    Revision 2.0
    NAP-200-005
    Sheet 4/4
    Connection of Battery
    (2) Plug the battery cable connector into the BATT1 connector on the PZ-PW86/PZ-PW112 as shown in Fig-
    ure 005-3.
    (3) Secure the batteries and battery cable using tie wraps.
    Figure 005-3  Internal Battery Connection
    PLUG IN TO BATT 1
    CONNECTOR ON PZ-PW86
    FRONT
    TIE WRAP
    BASEPIM 
    						
    							CHAPTER 3 NDA-24219  
    Page 48
    Revision 2.0
    NAP-200-006
    Sheet 1/2
    Cable Running to MDF
    1. MDF CABLE
    To facilitate the termination of the 25 pair cables (MDF cables) from the system to the MDF, the length of each cable
    to be used should be predetermined according to the distance between the MDF and the system. Each cable should
    be labeled at both ends using a cable number or cable designation as shown in Figure 006-1.
    Figure 006-1  MDF Cable FROM
    CABLE
    NUMBERTOCABLE
    DESTINATION
    MODULE CONNECTION
    PIM0LT C 0 1
    MDF0 LTC0
    LT C 1 2 0  LT C 1
    PIM1LT C 0 3
    MDF1 LTC0
    LT C 1 4 1  LT C 1
    TO PIMCHAMP CONNECTOR
    TWISTED 25 PAIR CABLES
    TO MDF 
    						
    							 NDA-24219 CHAPTER 3
    Pag e 49
    Revision 2.0
    NAP-200-006
    Sheet 2/2
    Cable Running to MDF
    2. CABLE RUNNING TO EXTERNAL MDF
    (1) Bring the MDF cable up to the Main Equipment through the cable hole(s) of the bottom cover.
    (2) Connect the champ connector of each MDF cable to an LTC connector located on a PIM using the screws
    provided, as shown in Figure 006-2.
    (3) Pare the sheath of each MDF cable and secure the shield to the bottom of the PIM using tie wraps, as shown
    in Figure 006-2.
    Figure 006-2  Cable Running to External MDF
    LTC CONNECTOR
    CHAMP CONNECTOR
    FRONT
    TO MDF PIMPBX
    PIM
    MDF
    CABLE
    TIE WRAP
    25-30 mm
    (1.0-1.2 inch)
    SHIELD 
    						
    							CHAPTER 3 NDA-24219  
    Page 50
    Revision 2.0
    NAP-200-007
    Sheet 1/55
    Termination of Cables on MDF
    1. CABLE CONNECTION TO MDF
    (1) Connect the cables to the MDF referring to Figure 007-1 and Table 007-1.
    Figure 007-1  Card Slots and LTC Connectors Location
    Table 007-1  LTC Connector Accommodation
    LTC CONNECTOR CARD SLOT NUMBER REMARKS
    LT C 0 LT 0 1  ~  LT 0 3
    LT C 1LT04/AP0 ~ LT08/AP4 When AD8 is mounted in LT00, pins 25 
    and 50, bring out leads for AD8 internal 
    modem connection.
    00
    LT01
    LT02
    LT03
    LT04
    LT
    /
    AP005
    LT
    /
    AP106
    LT
    /
    AP207
    LT
    /
    AP308
    LT
    /
    AP409
    MP
    /
    BUS
    P
    W
    R
    LT C 1
    LT C 0
    Vacant
    Space
    PIM 
    						
    							 NDA-24219 CHAPTER 3
    Page 51
    Revision 2.0
    NAP-200-007
    Sheet 2/55
    Termination of Cables on MDF
    (2)Figure 007-2 shows the relationship between each Line Equipment Number (LEN) and each Card Slot
    Number (LT Number).
    Figure 007-2  Location of Each LEN
    Note 1:Do not mount line/trunk circuit card with cabling in this slot; this slot has no connection to the MDF via the
    backplane (LTC cables).
    Note 2:When an 8-port line/trunk card, which requires cabling to MDF, is mounted in Slot 04, Slot 05 must be left
    vacant or mounted with circuit cards
    1 that do not interfere with the 8-port card mounted in LT04.
    Note 3:When an 8-port line/trunk card, which requires cabling to MDF is mounted in SLot 06, Slot 07 must be left
    vacant or mounted with circuit cards
    1 that do not interfere with the 8-port card mounted in LT06.
    Note 4:When using internal DTMF Receiver (4RST) on MP card, assign Card No. E200 to LEN No. 0124.
    Note 5:If single-line cards are mounted in LT or LT/AP slots, an external ring generator must be connected to
    PWR0B. The system power supply does not provide these voltages. It is recommended that the APR adapter
    be used in dual-port mode to provide for single-line devices.
    1 When an 8-port card is mounted in Slot 04/06, Slot 05/07 can only be mounted with the following cards:
    SPN-AP00 SPN-AP01 SPN-ME00 SPN-SC01
    SPN-SC02 SPN-4RSTB SPN-4RSTB-911 SPN-4RSTC
    SPN-CK00 SPN-CC00 PN-M03 SPN-SC03 (CSH)/(ICH)
     
    Note 1 Note 2 Note 3
    PIM 10127 0071 0079 0087 0095 0103 0111
    LEN
    (LINE EQUIPMENT NUMBER) 0126 0070 0078 0086 0094 0102 0110
    0125 0069 0077 0085 0093 0101 0109
    0124 0068 0076 0084 0092 0100 0108
    0123 0067 0075 0083 0091 0095 0099 0103 0107
    0122 0066 0074 0082 0090 0094 0098 0102 0106
    0121 0065 0073 0081 0089 0093 0097 0101 0105
    0120 0064 0072 0080 0088 0092 0096 0100 0104
    (LT00) (LT01) (LT02) (LT03) (LT04) (LT05) (LT06) (LT07) (LT08)
    CARD SLOT NUMBER
    PIM 00063 0007 0015 0023 0031 0039 0047
    LEN
    (LINE EQUIPMENT NUMBER) 0062 0006 0014 0022 0030 0038 0046
    0061 0005 0013 0021 0029 0037 0045
    0060 0004 0012 0020 0028 0036 0044
    0059 0003 0011 0019 0027 0031 0035 0039 0043
    0058 0002 0010 0018 0026 0030 0034 0038 0042
    0057 0001 0009 0017 0025 0029 0033 0037 0041
    0056 0000 0008 0016 0024 0028 0032 0036 0040
    (LT00) (LT01) (LT02) (LT03) (LT04) (LT05) (LT06) (LT07) (LT08) CARD SLOT NUMBER
    Note 1 Note 2 Note 3 
    						
    							CHAPTER 3 NDA-24219  
    Page 52
    Revision 2.0
    NAP-200-007
    Sheet 3/55
    Termination of Cables on MDF
    (3)Figure 007-3 shows the LTC connector pin arrangement.
    Figure 007-3  LTC Connector Pin Arrangement
    LTC0
    26 1 LEN0000
    LT01 27 2 0001
    28 3 0002
    29 4 0003
    30 5 0004
    31 6 0005
    32 7 0006
    33 8 0007
    34 9 0008
    LT02 35 10 0009
    36 11 0010
    37 12 0011
    38 13 0012
    39 14 0013
    40 15 0014
    41 16 0015
    42 17 0016
    LT03 43 18 0017
    44 19 0018
    45 20 0019
    46 21 0020
    47 22 0021
    48 23 0022
    49 24 LEN0023
    50 MN 25 MJLTC1
    26 1 LEN0024
    LT04/AP0/LT05/AP1 27 2 0025
    28 3 0026
    29 4 0027
    30 5 0028
    31 6 0029
    32 7 0030
    33 8 0031
    34 9 0032
    LT06/AP2/LT07/AP3 35 10 0033
    36 11 0034
    37 12 0035
    38 13 0036
    39 14 0037
    40 15 0038
    41 16 0039
    42 17 0040
    LT08 43 18 0041
    44 19 0042
    45 20 0043
    46 21 0044
    47 22 0045
    48 23 0046
    49 24 LEN0047
    50 * 25 *
    * When AD8 is mounted in LT00, pins 25 and 50 of LTC1 bring out the AD8 internal modem leads.•PIM0 
    						
    							 NDA-24219 CHAPTER 3
    Page 53
    Revision 2.0
    NAP-200-007
    Sheet 4/55
    Termination of Cables on MDF
    Figure 007-3  LTC Connector Pin Arrangement (Continued)
    LTC0
    26 1 LEN0064
    LT01 27 2 0065
    28 3 0066
    29 4 0067
    30 5 0068
    31 6 0069
    32 7 0070
    33 8 0071
    34 9 0072
    LT02 35 10 0073
    36 11 0074
    37 12 0075
    38 13 0076
    39 14 0077
    40 15 0078
    41 16 0079
    42 17 0080
    LT03 43 18 0081
    44 19 0082
    45 20 0083
    46 21 0084
    47 22 0085
    48 23 0086
    49 24 LEN0087
    50 25LTC1
    26 1 LEN0088
    LT04/AP0/LT05/AP1 27 2 0089
    28 3 0090
    29 4 0091
    30 5 0092
    31 6 0093
    32 7 0094
    33 8 0095
    34 9 0096
    LT06/AP2/LT07/AP3 35 10 0097
    36 11 0098
    37 12 0099
    38 13 0100
    39 14 0101
    40 15 0102
    41 16 0103
    42 17 0104
    LT08/AP4 43 18 0105
    44 19 0106
    45 20 0107
    46 21 0108
    47 22 0109
    48 23 0110
    49 24 LEN0111
    50 * 25 *
    * When AD8 is mounted in LT00, pins 25 and 50 of LTC1 bring out the AD8 internal modem leads.•PIM1 
    						
    							CHAPTER 3  NDA-24219    
    NAP-200-007
    Note 1
    Note 1 
    						
    							 NDA-24219 CHAPTER 3
    Page 55
    Revision 2.0
    NAP-200-007
    Sheet 6/55
    Termination of Cables on MDF
    * Major and minor alarm connections are used for external indications.
    Note 1:When an 8-port card is mounted in LT04 or LT06, LT05 or LT07 must be left vacant or mounted with circuit card,
    which do not interfere with the 8-port cards.
    Note 2:When NEAXmail AD8 is mounted in LT00, the pins on LTC1 are used for NEAXmail AD8 internal modem connection.Table 007-2  LTC0 and LTC1 MDF Cross Connection Information (Continued)
    PINRUNNING
    CABLESTATION
    CABLESLOTSTYPE OF INTERFACE
    CO
    (4COT)CO
    (8COT)2-WIRE 
    E&M TIE 
    LINE
    (2ODT)4-WIRE 
    E&M TIE 
    LINE
    (2ODT)DID
    (AUC)DID
    (4DIT)SLT
    (8LC)SLT
     (4LC)SLT
    (AUC)
    42 YL-OR GN
    3T0 T0 T0 TxT0 T0 T0 T0 T0 T0
    17OR-YL RD R0R0 R0 TxR0R0R0R0R0R0
    43 YL-GN BK T1 T1 RcvT0 T1 T1 T1 T1 T1
    18 GN-YL YL R1 R1 RcvR0 R1 R1 R1 R1 R1
    44YL-BR GN T2T2 T1 TxT1 T2T2T2
    19 BR-YL RD R2 R2 R1 TxR1 R2 R2 R2
    45 YL-SL BK T3 T3 RcvT1 T3 T3 T3
    20 SL-YL YL R3 R3 RcvR1 R3 R3 R3
    46 VI-BL GN T0 T4 T0 TxT0 T0 T0 T4 T0 T0
    21BL-VI RD R0R4 R0 TxR0R0R0R4R0R0
    47 VI-OR BK T1 T5 RcvT0 T1 T1 T5 T1 T1
    22 OR-VI YL R1 R5 RcvR0 R1 R1 R5 R1 R1
    48VI-GN GN T2T6 T1 TxT1 T2T6T2
    23 GN-VI RD R2 R6 R1 TxR1 R2 R6 R2
    49 VI-BR BK T3 T7 RcvT1 T3 T7 T3
    24 BR-VI YL R3 R7 RcvR1 R3 R7 R3
    50 VI-SL MN*
    Note 2
    25 SL-VI MJ* 
    						
    							CHAPTER 3 NDA-24219  
    Page 56
    Revision 2.0
    NAP-200-007
    Sheet 7/55
    Termination of Cables on MDF
    Note 1:When LT04 or LT06 is mounted with an 8-port card, LT05 and/or LT07 must be vacant or mounted with a noninter-
    facing card.
    Note 2:2 wire type for Multiline Terminal/DSS Console/DESKCON.
    Note 3:4 wire type for Multiline Terminal/SN610 ATTCON.Table 007-2  LTC0 and LTC1 MDF Cross Connection Information (Continued)
    PINRUNNING
    CABLESTATION
    CABLESLOTSTYPE OF INTERFACE
    Multiline 
    Terminal
    (8DLC)
    Note 2Multiline 
    Terminal
    (4DLC)
    Note 2Multiline 
    Te r m i n a l
    (2DLCB)
    Note 2SN610
    ATTCON
    (2DLCC)
    Note 3EXT. KEY
    (DK00)EXT. 
    RELAY
    (DK00)EXT.
    PA G E /
    MOH/
    BGM
    (4COT)
    26
    1WH-BL
    BL-WHGN
    RD
    1T0
    R0T0
    R0T0
    R0RA0
    TA 0K1
    K0K1
    K0T
    R
    27
    2WH-OR
    OR-WHBK
    YLT1
    R1T1
    R1T1
    R1RB0
    TB0K3
    K2K3
    K2T
    R
    28
    3WH-GN
    GN-WHGN
    RDT2
    R2T2
    R2RA1
    TA 1K5
    K4K5
    K4T
    R
    29
    4WH-BR
    BR-WHBK
    YLT3
    R3T3
    R3RB1
    TB1K7
    K6K7
    K6T
    R
    30
    5WH-SL
    SL-WHGN
    RDT4
    R4
    31
    6RD-BL
    BL-RDBK
    YLT5
    R5
    32
    7RD-OR
    OR-RDGN
    RDT6
    R6
    33
    8RD-GN
    GN-RDBK
    YLT7
    R7
    34
    9RD-BR
    BR-RDGN
    RD
    2T0
    R0T0 T0 RA0 K1 K1 T
    R0 R0 TA0 K0 K0 R
    35
    10RD-SL
    SL-RDBK
    YLT1
    R1T1 T1 RB0 K3 K3 T
    R1 R1 TB0 K2 K2 R
    36
    11BK-BL
    BL-BKGN
    RDT2
    R2T2 RA1 K5 K5 T
    R2 TA1 K4 K4 R
    37
    12BK-OR
    OR-BKBK
    YLT3
    R3T3 RB1 K7 K7 T
    R3 TB1 K6 K6 R
    38
    13BK-GN
    GN-BKGN
    RDT4
    R4
    39
    14BK-BR
    BR-BKBK
    YLT5
    R5
    40
    15BK-SL
    SL-BKGN
    RDT6
    R6
    41
    16YL-BL
    BL-YLBK
    YLT7
    R7
    Note 1
    Note 1 
    						