Home > NEC > Communications System > NEC Neax 1000 Ivs Very Small Platform System Manual

NEC Neax 1000 Ivs Very Small Platform System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 1000 Ivs Very Small Platform System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 NDA-24219 CHAPTER 3
    Page 57
    Revision 2.0
    NAP-200-007
    Sheet 8/55
    Termination of Cables on MDF
    * Major and minor alarm connections are used for external indications.
    Note 1:When LT04 or LT06 is mounted with an 8-port card, LT05 and/or LT07 must be vacant or mounted with a noninter-
    facing card.
    Note 2:2 wire type for Multiline Terminal/DSS Console/DESKCON.
    Note 3:4 wire type for Multiline Terminal/SN610 ATTCON.
    Note 4:When NEAXmail AD8 is mounted in LT00, the pins on LTC1 are used for NEAXmail AD8 internal modem connection.Table 007-2  LTC0 and LTC1 MDF Cross Connection Information (Continued)
    PINRUNNING
    CABLESTATION
    CABLESLOTSTYPE OF INTERFACE
    Multiline 
    Terminal
    (8DLC)
    Note 2Multiline 
    Terminal
    (4DLC)
    Note 2Multiline 
    Te r m i n a l
    (2DLCB)
    Note 2SN610
    ATTCON
    (2DLCC)
    Note 3EXT. KEY
    (DK00)EXT. 
    RELAY
    (DK00)EXT.
    PA G E /
    MOH/
    BGM
    (4COT)
    42 YL-OR GN
    3T0 T0 T0 RA0 K1 K1 T
    17 OR-YL RD R0 R0 R0 TA0 K0 K0 R
    43 YL-GN BK T1 T1 T1 RB0 K3 K3 T
    18 GN-YL YL R1 R1 R1 TB0 K2 K2 R
    44 YL-BR GN T2 T2 RA1 K5 K5 T
    19 BR-YL RD R2 R2 TA1 K4 K4 R
    45 YL-SL BK T3 T3 RB1 K7 K7 T
    20 SL-YL YL R3 R3 TB1 K6 K6 R
    46 VI-BL GN T4 T0 T0 RA0 K1 K1 T
    21 BL-VI RD R4 R0 R0 TA0 K0 K0 R
    47 VI-OR BK T5 T1 T1 RB0 K3 K3 T
    22 OR-VI YL R5 R1 R1 TB0 K2 K2 R
    48 VI-GN GN T6 T2 RA1 K5 K5 T
    23 GN-VI RD R6 R2 TA1 K4 K4 R
    49 VI-BR BK T7 T3 RB1 K7 K7 T
    24 BR-VI YL R7 R3 TB1 K6 K6 R
    50 VI-SL MN*
    Note 425 SL-VI MJ* 
    						
    							CHAPTER 3 NDA-24219  
    Page 58
    Revision 2.0
    NAP-200-007
    Sheet 9/55
    Termination of Cables on MDF
    (1) C.O. Trunk
    (a) 4 Line C.O. Trunk (PN-4COT) (see Figure 007-4)
    Figure 007-4  MDF Cross Connection for 4 Line C.O. Trunk Card (PN-4COT)
    29T3294
    R3428
    T2283
    R2327
    T12726
    T026
    2
    1
    1R0 26T0
    2R1 27T1
    3R2 28T2
    4R3 29T3
    (P)
    26 T0 1 R0
    27 T1 2 R1
    28 T2 3 R2
    29 T3 4 R3LEN0000
    LEN0001
    LEN0002
    LEN0003
    LTC0 (J)MDF
    R01
    R12
    LEN0000      (No. 0)
    LEN0001      (No. 1)
    LEN0002      (No. 2)
    LEN0003      (No. 3)
    TO C.O. LINE
    TO C.O. LINE
    TO C.O. LINE
    TO C.O. LINE
    PIM0
    P PN-4COT
    LT01LTC0
    J 
    						
    							 NDA-24219 CHAPTER 3
    Page 59
    Revision 2.0
    NAP-200-007
    Sheet 10/55
    Termination of Cables on MDF
    (b) 8 Line C.O. Trunk (PN-8COT) (see Figure 007-5)
    Figure 007-5  MDF Cross Connection for 8 Line C.O. Trunk Card (PN-8COT)
    33T7338
    R7832
    T6327
    R6727
    T12726
    T026
    2
    1
    1R026T0
    2R127T1
    7R632T6
    8R733T7
    (P)
    26 T0 1 R0
    27 T1 2 R1
    32 T6 7 R6
    33 T7 8 R7LEN0000
    LEN0001
    LEN0006
    LEN0007
    LTC0 (J)MDF
    R01
    R12
    LEN0000       (No. 0)
    PIM0
    P PN-8COT
    LT01LTC0
    J
    LEN0001       (No. 1)
    LEN0006  (No. 6)
    LEN0007 (No. 7)
    TO C.O. LINE
    •
    •
    ••
    •
    ••
    •
    ••
    •
    •
    •
    •
    ••
    •
    ••
    •
    ••
    •
    ••
    •
    ••
    •
    ••
    •
    ••
    •
    • •
    •
    • 
    						
    							CHAPTER 3 NDA-24219  
    Page 60
    Revision 2.0
    NAP-200-007
    Sheet 11/55
    Termination of Cables on MDF
    (2) Tie Line Trunk
    (a) 4W E&M Trunk (PN-2ODT) (see Figure 007-6)
    Figure 007-6  MDF Cross Connection for 4W E&M Trunk Card (PN-2ODT)
    1
    26
    2
    27
    3
    28
    4
    29TxR0
    TxT0
    RcvR0
    RcvT0
    TxR1
    TxT1
    RcvR1
    RcvT1MDF
    LEN0001      (No. 1)
    LEN0000      (No. 0)PIM0
    PN-2ODT
    LT01
    LEN0001      (No. 1)
    1
    26
    2
    27
    3
    28
    4
    29
    (Rcv Tip)
    (Rcv Ring)
    (M)
    TO TIE LINE
    JPLTC0
    LEN0000      (No. 0)
    08
    07
    06
    05
    04 M1
    03 E1
    02 M0
    01 E0(E)
    (Tx Tip)
    (Tx Ring)
    JCN1
    INSTALLATION CABLE
    Note 1:Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in one PN-2ODT card.
    Note 2:When connecting the E and M, make the installation cable by using the connector attached with the PN-2ODT
    card. 
    						
    							 NDA-24219 CHAPTER 3
    Page 61
    Revision 2.0
    NAP-200-007
    Sheet 12/55
    Termination of Cables on MDF
    Figure 007-6  MDF Cross Connection for 4W E&M Trunk Card (PN-2ODT) (Continued)
    M1
    E1
    M0
    E0LEN0001
    LEN0000
    CN1
    1 LTC CONNECTOR2 CN1 CONNECTOR
    (FRONT CONNECTOR)
    LEN0000
    LEN00011 TxR0 26 TxT0
    2 RcvR0 27 RcvT0
    3 TxR1 28 TxT1
    4 RcvR1 29 RcvT1
    (P)
    26 TxT0 1 TxR0
    27 RcvT0 2 RcvR0
    28 TxT1 3 TxR1
    29 RcvT1 4 RcvR1
    LTC0 (J) 
    						
    							CHAPTER 3 NDA-24219  
    Page 62
    Revision 2.0
    NAP-200-007
    Sheet 13/55
    Termination of Cables on MDF
    (b) 2W E&M (PN-2ODT) (see Figure 007-7)
    Figure 007-7  MDF Cross Connection for 2W E&M Trunk Card (PN-2ODT)
    1
    26
    2
    27
    3
    28
    4
    29
    TO-10
    TO-9
    R0
    T0
    R1
    T1
    R2
    T2
    R3
    T3MDF
    LEN0001      (No. 1)
    LEN0000      (No. 0)PIM0
    PN-2ODT
    LT01
    LEN0001      (No. 1)
    1
    26
    2
    27
    3
    28
    4
    29
    (M)
    TO TIE LINE
    JPLTC0
    LEN0000      (No. 0)
    CN1
    08
    07
    06
    05
    04 M1
    03 E1
    02 M0
    01 E0(E)
    (Ring)
    (Tip)
    J
    INSTALLATION CABLE
    Note 1:Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in one PN-2ODT card.
    Note 2:When connecting the E and M, make the installation cable by using the connector attached with the PN-2ODT
    card. 
    						
    							 NDA-24219 CHAPTER 3
    Page 63
    Revision 2.0
    NAP-200-007
    Sheet 14/55
    Termination of Cables on MDF
    Figure 007-7  MDF Cross Connection for 2W E&M Trunk Card (PN-2ODT) (Continued)
    M1
    E1
    M0
    E0LEN0001
    LEN0000
    CN1
    1 LTC CONNECTOR2 CN1 CONNECTOR
    (FRONT CONNECTOR)
    LEN0000
    LEN00011R026T0
    227
    3R228T2
    429
    (P)
    26 T0 1 R0
    27 2
    28 T2 3 R2
    29 4
    LTC0 (J) 
    						
    							CHAPTER 3 NDA-24219  
    Page 64
    Revision 2.0
    NAP-200-007
    Sheet 15/55
    Termination of Cables on MDF
    (3) DID Trunk
    (a) 2 Line DID Trunk (PN-AUCA) (see Figure 007-8)
    Figure 007-8  MDF Cross Connection for 2 Line DID Trunk Card (PN-AUCA)
    29294
    428
    283
    327
    2726
    26
    2
    1
    LEN0000
    LEN0001MDF
    1
    2
    PIM0
    P PN-AUCA
    LT01LTC0
    J
    T1
    R1
    T0
    R0
    LEN0000   (No. 0)
    LEN0001   (No. 1)
    TO DID LINE
    1R026T0
    2R127T1
    328
    429
    (P)
    26 T0 1 R0
    27 T1 2 R1
    28 3
    29 4
    LTC0 (J)
    TO DID LINE
    Note:The PN-AUCA card can also be used as a long line circuit with the Power Failure Transfer (PFT) function. 
    						
    							 NDA-24219 CHAPTER 3
    Page 65
    Revision 2.0
    NAP-200-007
    Sheet 16/55
    Termination of Cables on MDF
    (b) 4 Line DID Trunk (PN-4DITB) (see Figure 007-9)
    Figure 007-9  MDF Cross Connection for 4 Line DID Trunk Card (PN-4DITB)
    29T3294
    R3428
    T2283
    R2327
    T12726
    T026
    2
    1
    1R026T0
    2R127T1
    3R228T2
    4R329T3
    (P)
    26 T0 1 R0
    27 T1 2 R1
    28 T2 3 R2
    29 T3 4 R3LEN0000
    LEN0001
    LEN0002
    LEN0003
    LTC0 (J)MDF
    R01
    R12
    LEN0000      (No. 0)
    LEN0001      (No. 1)
    LEN0002      (No. 2)
    LEN0003      (No. 3)
    TO DID LINE
    TO DID LINE
    TO DID LINE
    TO DID LINE
    PIM0
    P PN-4DITB
    LT01LTC0
    J 
    						
    							CHAPTER 3 NDA-24219  
    Page 66
    Revision 2.0
    NAP-200-007
    Sheet 17/55
    Termination of Cables on MDF
    (4) Single Line Telephone
    (a) Standard Line (PN-8LC) (see Figure 007-10)
    Figure 007-10  MDF Cross Connection for Single Line Telephone (Standard Line)
    33T7338
    R7832
    T6327
    R6727
    T12726
    T026
    2
    1
    1R026T0
    2R127T1
    7R632T6
    8R733T7
    (P)
    26 T0 1 R0
    27 T1 2 R1
    32 T6 7 R6
    33 T7 8 R7LEN0000
    LEN0001
    LEN0006
    LEN0007
    LTC0 (J)MDF
    R01
    R12
    LEN0000       (No. 0)
    PIM0
    P PN-8LC
    LT01LTC0
    J
    LEN0001       (No. 1)
    LEN0006  (No. 6)
    LEN0007 (No. 7)
    TO SINGLE
    LINE TELEPHONE
    Note:The same connection is required when using PN-4LC.
    •
    •
    ••
    •
    ••
    •
    ••
    •
    •
    •
    •
    ••
    •
    ••
    •
    ••
    •
    ••
    •
    ••
    •
    ••
    •
    ••
    •
    • •
    •
    • 
    						