    							 NDA-24219 CHAPTER 3
    Page 107
    Revision 2.0
    NAP-200-008
    Sheet 3/10
    Switch Setting of Circuit Card
    (3) Switch Setting (see Table 008-4)
    Table 008-4  PN-CP03 (MP) Card Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SW3 (Rotary SW)
    0 - FOn Line (Call processing is in progress)
    2Off Line (Call processing is stopped)
    • I/O port: Depending on CM40 YY=08
    3Off Line (Call processing is stopped)
    • I/O port: 1200bps (Fixed)
    B For clearing office data
    C For setting resident system program
    1, 4 - 9
    A, D - FNot used
    SW1 (Push SW) For initializing CPU
    SW2 (Piano Key SW)
    1
    ONKF Mode
    MF/PF Mode
    2, 3Selection of PLO (Phase Locked Oscillator)
    • When using internal PLO of MP card:
    0
    ON
    OFF
    4
    3
    2
    1
    OFF
    SWITCH 
    OFFON1.5MHz clock 
    [For PN-24DTA/PN-24DTA-A]
    192kHz clock 
    [For PN-BRTA]
    2MHz clock 
    [For PN-30DTC]
    Not used  OFF OFF
    ON OFF
    ON ON
    FUNCTION
    23NUMBER 
    						
    							CHAPTER 3 NDA-24219  
    Page 108
    Revision 2.0
    NAP-200-008
    Sheet 4/10
    Switch Setting of Circuit Card
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION col-
    umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
    , the setting of the switch varies with the system concerned.
    Note:Set the groove on the switch knob to the desired switch position.Table 008-4 PN-CP03 (MP) Card Switch Settings (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SW2 (Piano Key SW)
    2, 3• When using the PLO card (PN-CK00):
    SW2-2
    SW2-3OFF ON
    • When not using the internal PLO and the PLO card:
    SW2-2
    SW2-3OFF OFF
    4ONWhen using RS1 port for built-in 
    MODEM.
    OFFWhen using RS1 port for RS-232C.
    VR (Rotary SW) Variable Resistor for External Hold Tone 
    Source
    (0 - 20 K
    W: Clockwise)
    JP0 (Jumper pin) For normal operation
    Note:Do not remove this jumper. The
    power to RAM will be removed
    causing loss of Office Data Pro-
    gramming.
    DOWNNot used
    JP1 (Jumper pin) For normal operation
    Note:Do not relocate this jumper when
    power is turned on.
    DOWN
    For using External Tone Source
    ON
    OFF
    4
    3
    2
    1
    20
    0
    Front
    UP
    Front
    UP 
    						
    							 NDA-24219 CHAPTER 3
    Page 109
    Revision 2.0
    NAP-200-008
    Sheet 5/10
    Switch Setting of Circuit Card
    CAUTION:
    When the operating power is being supplied to this circuit card, do not plug/unplug this circuit
    card into/from its mounting slot.
    3. PZ-PW86 (PWR)
    (1) Locations of Lamps, Switches, and Connectors (see Figure 008-2)
    Figure 008-2  PZ-PW86 (PWR) Card
    FRONT VIEW BATT2 MN MJ
    ONBATTERY
    SIDE VIEW GND
    –27V FG
    OFFON
    240VAC 100/120VAC 2ON
    2
    1 ON
    SW301 START
    SIG
    1
    SW1
    BATT1
    AC INPUTMODE
    SW102
    • PZ-PW86(C)
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 3 NDA-24219  
    Page 110
    Revision 2.0
    NAP-200-008
    Sheet 6/10
    Switch Setting of Circuit Card
    Figure 008-2  PZ-PW86 (PWR) Card (Continued)
    (2) Lamp Indications (see Table 008-5)
    Table 008-5  PZ-PW86 (PWR) Card Lamp Indications
    LAMP NAME COLOR FUNCTION
    MJ Red Lights upon occurrence of a major fault.
    MN Yellow Lights upon occurrence of a minor fault.
    ON Green Remains lit while the power is on.
    FRONT VIEWBATT2 MN MJ
    ON
    BATTERY
    SIDE VIEW GND
    –27V FG
    OFFON 240VAC 100/120VAC2ON
    2
    1 ON SW102
    START
    SIG
    1
    SW1 BATT1 MODE
    SW301
    (CN103) SIG
    (CN103)
    • PZ-PW86(D)
    AC INPUT
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							 NDA-24219 CHAPTER 3
    Page 111
    Revision 2.0
    NAP-200-008
    Sheet 7/10
    Switch Setting of Circuit Card
    (3) Switch Settings (see Table 008-6)
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION col-
    umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
    , the setting of the switch varies with the system concerned.
    Table 008-6  PZ-PW86 (PWR) Card Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    Mode (Piano Key SW)
    1Always set to OFF
    2Standard setting for equalize charging (set to 
    equalize for Gel cell or no battery).
    OFF
    Float charging, for vented batteries only.
    SW1For turning AC power and the battery on
    OFFFor turning AC power and the battery off
    SW102 BATTERY START
    PRESS MO-
    MENTARILYTo start each PIM on battery power, when AC 
    power is not provided
    (switch “SW” must be ON)
    AC INPUT: 180 V - 264 V
    DOWNAC INPUT: 180 V - 264 V
    SW301
    1ONCR Voltage: 75 Vrms
    OFFCR Voltage: 90 Vrms
    2ONFrequency: 20 Hz
    OFFFrequency: 25 Hz
    1
    2
    ON
    OFF
    ON
    ON (–)
    OFF (O)
    ON
    240 VAC 100/120 VAC
    UP
    2
    1ONOFF 20Hz 25Hz
    75V 90V 
    						
    							CHAPTER 3  NDA-24219    
    NAP-200-008
    FRONT V IEW
    ST ART
    SW1
    SW102
    BATT0
    CN103 
    						
    							 NDA-24219   CHAPTER 3
    NAP-2 00-008
    ON (–) 
    						
    							CHAPTER 3  NDA-24219    
    NAP-200-008
    BL7BL6 
    						
    							 NDA-24219 CHAPTER 3
    Page 115
    Revision 2.0
    NAP-200-009
    Sheet 1/3
    Mounting Circuit Cards
    1. MOUNTING PROCEDURE
    (1) For testing, turn on “SW1” switch on the PZ-PW86/PZ-PW112 card. Make sure that “ON” lamp (green) is
    lit. See Figure 009-1.
    (2) Turn off “SW1” switch.
    Figure 009-1  PZ-PW86/PZ/PW112 Card Lamp Indication
    PZ-PW86/PW112
    ON
    OFFSW SWITCH
    ON LAMP (GREEN)MN
    MJ
    ON 
    						
    							CHAPTER 3 NDA-24219  
    Page 116
    Revision 2.0
    NAP-200-009
    Sheet 2/3
    Mounting Circuit Cards
    (3) Before mounting the circuit cards, confirm the following items.
    • Wrist Strap is connected Frame Ground.
    • Switch setting of circuit cards is already completed (Refer to the Circuit Card Manual).
    • “SW1” switch of PZ-PW86PZ/PW112 Card is turned off.
    (4) Mount circuit cards into their mounting positions according to the “Bay Face Layout” and “Port Assign-
    ment Table” given in the System Data Sheet.
    Figure 009-2 shows the mounting method of circuit cards.
    Figure 009-2  Mounting Circuit Cards
    CARD FRONT SIDE
    WRIST STRAP
    TO FRAME GROUND CONNECTION
    (SEE FIGURE 3-1)
    CARD CONTACT SIDE 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 1000 Ivs Very Small Platform System Manual