    							 NDA-24219   CHAPTER 3
    NAP-2 00-003
    PZ-PW86 (C)
    PW R CNT C A-A/
    FRAME G ROUND TERMINAL  ON THE CHASSIS
    C A UTION :Set the app ropri ate  voltage be fo re
    Note 1 :Follow the Labe l on the f ront plate of the PZ-PW86.
    B ATTE RY CONNEC TO R  (B ATT1)
    1Note 1
    1 :NO CONNECTI ON 
    						
    							CHAPTER 3 NDA-24219  
    Page 38
    Revision 2.0
    NAP-200-003
    Sheet 9/12
    Installation of Main Equipment
    Figure 003-7 Cable Connection on PZ-PW86/PW112 (Continued)
    PZ-PW86(D)
    MJ
    MN
    ON
    BATTERY MODE SWITCH
    GND  
    Note 2
    FG
    –27V
    PWR CNT CA-A/ TO PWR1
    AC CORD-A
    TO AC MAINS INPUT TO TO PWR0A CONNECTOR POWER OUTPUT
    CONNECTOR TO AUXILIARY 
    BATTERY CONNECTOR (BATT2)
    ON
    OFF 100/120V
    240V EQUIPMENT
    GREEN WHITE
    BLACK
    FRAME GROUND
    Note 1: Follow the Label on Front Plate of
    PZ-PW86(D).
    Note 2: If GND (Signal GND) has to be
    separated from FG (Frame GND),
    remove the link between GND and
    FG terminal
    1: NO CONNECTION
    2: ON-SEAL/FLOAT 2
    –
    O1
    2ON
    TERMINAL ON THE 
    Note 1
    TO OTHER PZ-PW86
    PWR CA-A
    TO BATTERY OR
    OTHER PZ-PW86
    BATTERY CONNECTOR (BATT1)
    BATTERY CABLE/PWR CA-A
    CHASSIS
    • PZ-PW86(D)
    CAUTION:Set the appropriate volt-
    age before turning on the
    SW switch.
    CABLE (+5V, –27V,E)
    PWR CNT CA-C OFF-OPEN/FLOAT 1 
    						
    							 NDA-24219 CHAPTER 3
    Page 39
    Revision 2.0
    NAP-200-003
    Sheet 10/12
    Installation of Main Equipment
    Figure 003-7 Cable Connection on PZ-PW86/PW112 (Continued)
    PZ-PW112
    MJ
    MN
    ON
    GND  
    Note
    FG
    –27V
    PWR CNT CA-A/ TO PWR1
    AC CORD-A
    TO AC MAINS INPUT TO  CONNECTOR TO AUXILIARY 
    BATTERY CONNECTOR (BATT2)
    ON
    OFF EQUIPMENT
    GREEN WHITE
    BLACK
    FRAME GROUND
    Note: If GND (Signal GND) has to be
    separated from FG (Frame GND),
    remove the link between GND and
    FG terminal
    –
    O
    TERMINAL ON THE  TO OTHER PZ-PW112
    PWR CA-A
    TO BATTERY OR
    OTHER PZ-PW112
    BATTERY CONNECTOR (BATT1)
    BATTERY CABLE/PWR CA-A
    CHASSIS
    • PZ-PW112
    TO PWR0A CONNECTOR POWER OUTPUT
    CABLE (+5V, –27V,E)
    PWR CNT CA-C 
    						
    							CHAPTER 3  NDA-24219    
    NAP-200-003
    LTC CONNECTOR AREA
    PI M1
    PWR0C
    PWR C NT CA -C
    LTC CON NECTOR AREA
    PIM0
    PWR0C
    P WR  CNT CA-C 
    						
    							 NDA-24219 CHAPTER 3
    Page 41
    Revision 2.0
    NAP-200-003
    Sheet 12/12
    Installation of Main Equipment
    (3) Bring the AC CORD-A-U out of the PIM through the cable hole on the bottom of the lower PIM, and plug
    it into a commercial AC outlet.
    Figure 003-9  AC Power Cable Wiring
    AC CORD-A-U
    TO FGTERMINAL 
    						
    							CHAPTER 3  NDA-24219    
    NAP-200-004
    PIM1
    Note :
    For details of battery connectio n, see NAP- 200-00 4.
    P WR C A-A
    PIM1
    P WR C A-A
    TO B ATT ER Y
    TO B ATT ER Y 
    						
    							 NDA-24219 CHAPTER 3
    Page 43
    Revision 2.0
    NAP-200-004
    Sheet 2/2
    PWR CA-A and BUS Cable Connection
    (2) Mount the BS00 Card in the BUS slot of PIM0. Also, mount the BS01 Card in the BUS slot of PIM1.
    When the system is a single PIM configuration, neither PN-BS00 nor PN-BS01 is needed.
    (3) Connect the BUS cards using BUS cable (48-TW-0.7 CONN CA).
    Figure 004-2  Mounting BUS Cards
    PIM1
    PIM0BS01
    CN2
    CN1
    BS00
    CN2
    CN1
    48-TW-0.7
    CONN CA 
    						
    							CHAPTER 3 NDA-24219  
    Page 44
    Revision 2.0
    NAP-200-005
    Sheet 1/4
    Connection of Battery
    1. BATTERY CONNECTION
    CAUTION 1:24V batteries must be used in this system.
    CAUTION 2:If battery terminals (+, –) contact with the module under connecting the battery cable to the PZ-
    PW86/PW112 card, the PZ-PW86/PW112 card or the BWB may be broken. Therefore, the in-
    staller must perform work in accordance with the following steps when mounting or removing
    the batteries.
    • When mounting batteries:
    (1) Connect the battery cable to the batteries.
    (2) Mount the batteries into the appointed position of the PIM.
    (3) Connect the battery cable to the PZ-PW86/PW112 card.
    • When removing batteries:
    (1) Disconnect the battery cable from the PZ-PW86/PW112 card.
    (2) Remove the batteries from the PIM.
    Standard Battery
    Internal Battery : GS type PX 12026
    Optional Battery
    External Battery : YUASA
    MATUSHITAtype
    typeNPH-3.2-12
    LCR-12V-3.4NE
    These batteries will provide 30 minutes of battery backup. They will 
    not fit within the NEAX1000 PIM. 
    						
    							 NDA-24219 CHAPTER 3
    Page 45
    Revision 2.0
    NAP-200-005
    Sheet 2/4
    Connection of Battery
    CAUTION 3:
    Battery Replacement Table and Battery Warnings
    The label, which shows battery replacement table and battery warnings, is attached to the re-
    verse side of Front Cover for PIM. During the battery installation process, always observe the
    warning statements. When replacing batteries, adhere to the battery replacement table to in-
    crease battery life and to insure safe operation. See Figure 005-1.
    Figure 005-1  Battery Replacement Information
    LABEL PIM
    FRONT COVER
    • ELECTROLYTE LEAKAGE OR OTHER HAZARDS MAY 
    RESULT IF THE BATTERY IS NOT REPLACED IN 
    ACCORDANCE WITH THE SPECIFIED INTERVALS.
    AMBIENT
    TEMPERATURE25
    °C
    (77
    ° F)25
    °C~30
    °C
    (77
    ° ~86
    ° F)30
    °C~40
    °C
    (86
    ° ~104
    ° F)
    REPLACEMENT 
    INTERVAL2.5~3.0
    YEARS2.0~2.5
    YEARS1.5~2.0
    YEARS
    TO PREVENT INJURY AND SKIN BURN, PAY 
    ATTENTION TO THE FOLLOWING.
    • DO NOT STRIKE A MATCH OR CAUSE A SPARK IN 
    VICINITY OF BATTERY.
    • PLACE THE EQUIPMENT IN A WELL VENTILATED 
    AREA.
    • DO NOT SHORT.
    • REPLACE BATTERY ONLY AFTER BATTERY GASES 
    HAVE BEEN DISPERSED.CAUTION BATTERY REPLACEMENT TABLEINSTALLATION DATE:,. 
    						
    							CHAPTER 3 NDA-24219  
    Page 46
    Revision 2.0
    NAP-200-005
    Sheet 3/4
    Connection of Battery
    1.1 Internal Battery Connection
    (1) Mount the battery unit (24V DC, 2.6 AH) into the PIM (standard with system) as shown in Figure 005-2.
    Figure 005-2  Internal Battery Mounting
    FRONT 34mmDIMENSION OF BATTERY BATTERY UNIT
    (2´
    12V DC, 2.6 AH)
    (STANDARD)
    (1.3 inches)
    178mm
    (7 inches) 60mm
    (2.4 inches)
    PIM
    Red
    Blue Black
    +–+
    – 
    						