NDA-24219 CHAPTER 3 NAP-2 00-003 PZ-PW86 (C) PW R CNT C A-A/ FRAME G ROUND TERMINAL ON THE CHASSIS C A UTION :Set the app ropri ate voltage be fo re Note 1 :Follow the Labe l on the f ront plate of the PZ-PW86. B ATTE RY CONNEC TO R (B ATT1) 1Note 1 1 :NO CONNECTI ON
CHAPTER 3 NDA-24219 Page 38 Revision 2.0 NAP-200-003 Sheet 9/12 Installation of Main Equipment Figure 003-7 Cable Connection on PZ-PW86/PW112 (Continued) PZ-PW86(D) MJ MN ON BATTERY MODE SWITCH GND Note 2 FG –27V PWR CNT CA-A/ TO PWR1 AC CORD-A TO AC MAINS INPUT TO TO PWR0A CONNECTOR POWER OUTPUT CONNECTOR TO AUXILIARY BATTERY CONNECTOR (BATT2) ON OFF 100/120V 240V EQUIPMENT GREEN WHITE BLACK FRAME GROUND Note 1: Follow the Label on Front Plate of PZ-PW86(D). Note 2: If GND (Signal GND) has to be separated from FG (Frame GND), remove the link between GND and FG terminal 1: NO CONNECTION 2: ON-SEAL/FLOAT 2 – O1 2ON TERMINAL ON THE Note 1 TO OTHER PZ-PW86 PWR CA-A TO BATTERY OR OTHER PZ-PW86 BATTERY CONNECTOR (BATT1) BATTERY CABLE/PWR CA-A CHASSIS • PZ-PW86(D) CAUTION:Set the appropriate volt- age before turning on the SW switch. CABLE (+5V, –27V,E) PWR CNT CA-C OFF-OPEN/FLOAT 1
NDA-24219 CHAPTER 3 Page 39 Revision 2.0 NAP-200-003 Sheet 10/12 Installation of Main Equipment Figure 003-7 Cable Connection on PZ-PW86/PW112 (Continued) PZ-PW112 MJ MN ON GND Note FG –27V PWR CNT CA-A/ TO PWR1 AC CORD-A TO AC MAINS INPUT TO CONNECTOR TO AUXILIARY BATTERY CONNECTOR (BATT2) ON OFF EQUIPMENT GREEN WHITE BLACK FRAME GROUND Note: If GND (Signal GND) has to be separated from FG (Frame GND), remove the link between GND and FG terminal – O TERMINAL ON THE TO OTHER PZ-PW112 PWR CA-A TO BATTERY OR OTHER PZ-PW112 BATTERY CONNECTOR (BATT1) BATTERY CABLE/PWR CA-A CHASSIS • PZ-PW112 TO PWR0A CONNECTOR POWER OUTPUT CABLE (+5V, –27V,E) PWR CNT CA-C
CHAPTER 3 NDA-24219 NAP-200-003 LTC CONNECTOR AREA PI M1 PWR0C PWR C NT CA -C LTC CON NECTOR AREA PIM0 PWR0C P WR CNT CA-C
NDA-24219 CHAPTER 3 Page 41 Revision 2.0 NAP-200-003 Sheet 12/12 Installation of Main Equipment (3) Bring the AC CORD-A-U out of the PIM through the cable hole on the bottom of the lower PIM, and plug it into a commercial AC outlet. Figure 003-9 AC Power Cable Wiring AC CORD-A-U TO FGTERMINAL
CHAPTER 3 NDA-24219 NAP-200-004 PIM1 Note : For details of battery connectio n, see NAP- 200-00 4. P WR C A-A PIM1 P WR C A-A TO B ATT ER Y TO B ATT ER Y
NDA-24219 CHAPTER 3 Page 43 Revision 2.0 NAP-200-004 Sheet 2/2 PWR CA-A and BUS Cable Connection (2) Mount the BS00 Card in the BUS slot of PIM0. Also, mount the BS01 Card in the BUS slot of PIM1. When the system is a single PIM configuration, neither PN-BS00 nor PN-BS01 is needed. (3) Connect the BUS cards using BUS cable (48-TW-0.7 CONN CA). Figure 004-2 Mounting BUS Cards PIM1 PIM0BS01 CN2 CN1 BS00 CN2 CN1 48-TW-0.7 CONN CA
CHAPTER 3 NDA-24219 Page 44 Revision 2.0 NAP-200-005 Sheet 1/4 Connection of Battery 1. BATTERY CONNECTION CAUTION 1:24V batteries must be used in this system. CAUTION 2:If battery terminals (+, –) contact with the module under connecting the battery cable to the PZ- PW86/PW112 card, the PZ-PW86/PW112 card or the BWB may be broken. Therefore, the in- staller must perform work in accordance with the following steps when mounting or removing the batteries. • When mounting batteries: (1) Connect the battery cable to the batteries. (2) Mount the batteries into the appointed position of the PIM. (3) Connect the battery cable to the PZ-PW86/PW112 card. • When removing batteries: (1) Disconnect the battery cable from the PZ-PW86/PW112 card. (2) Remove the batteries from the PIM. Standard Battery Internal Battery : GS type PX 12026 Optional Battery External Battery : YUASA MATUSHITAtype typeNPH-3.2-12 LCR-12V-3.4NE These batteries will provide 30 minutes of battery backup. They will not fit within the NEAX1000 PIM.
NDA-24219 CHAPTER 3 Page 45 Revision 2.0 NAP-200-005 Sheet 2/4 Connection of Battery CAUTION 3: Battery Replacement Table and Battery Warnings The label, which shows battery replacement table and battery warnings, is attached to the re- verse side of Front Cover for PIM. During the battery installation process, always observe the warning statements. When replacing batteries, adhere to the battery replacement table to in- crease battery life and to insure safe operation. See Figure 005-1. Figure 005-1 Battery Replacement Information LABEL PIM FRONT COVER • ELECTROLYTE LEAKAGE OR OTHER HAZARDS MAY RESULT IF THE BATTERY IS NOT REPLACED IN ACCORDANCE WITH THE SPECIFIED INTERVALS. AMBIENT TEMPERATURE25 °C (77 ° F)25 °C~30 °C (77 ° ~86 ° F)30 °C~40 °C (86 ° ~104 ° F) REPLACEMENT INTERVAL2.5~3.0 YEARS2.0~2.5 YEARS1.5~2.0 YEARS TO PREVENT INJURY AND SKIN BURN, PAY ATTENTION TO THE FOLLOWING. • DO NOT STRIKE A MATCH OR CAUSE A SPARK IN VICINITY OF BATTERY. • PLACE THE EQUIPMENT IN A WELL VENTILATED AREA. • DO NOT SHORT. • REPLACE BATTERY ONLY AFTER BATTERY GASES HAVE BEEN DISPERSED.CAUTION BATTERY REPLACEMENT TABLEINSTALLATION DATE:,.
CHAPTER 3 NDA-24219 Page 46 Revision 2.0 NAP-200-005 Sheet 3/4 Connection of Battery 1.1 Internal Battery Connection (1) Mount the battery unit (24V DC, 2.6 AH) into the PIM (standard with system) as shown in Figure 005-2. Figure 005-2 Internal Battery Mounting FRONT 34mmDIMENSION OF BATTERY BATTERY UNIT (2´ 12V DC, 2.6 AH) (STANDARD) (1.3 inches) 178mm (7 inches) 60mm (2.4 inches) PIM Red Blue Black +–+ –