NDA-24219 CHAPTER 2 Page 7 Revision 2.0 Figure 2-4 19-Inch Rack-Mounting Installation PIM 19”BRACKET (H)
CHAPTER 2 NDA-24219 Page 8 Revision 2.0 Figure 2-5 Desktop Installation PIM
NDA-24219 CHAPTER 2 Page 9 Revision 2.0 3. FUNCTIONAL OUTLINE OF EQUIPMENT This section explains the functional outline of the equipment (modules, installation hardware, circuit cards) used in the PBX. 3.1 Functional Outline of Modules Table 2-2 shows the functional outline of the modules. 3.2 Functional Outline of Installation Hardware Table 2-3 shows the functional outline of installation hardware. Table 2-2 Functional Outline of Modules MODULESFUNCTIONAL NAMEFUNCTIONAL OUTLINE SN1420 PIMAB-A PIM Port Interface Module (PIM) A PIM provides 10 card slots for common control, Line/Trunk, and Application Processor (AP) cards. It also houses a AC/DC Power Supply and batteries for protection from short-term power interruption (standard). Two champ connectors for line/trunk (LTC0 to 1) and a connector for Power (PWR) are located at the lower front side of the PIM. A PIM provides a maximum of 9 card slots for line/trunk (LT) cards. At maximum configuration, the system is comprised of 2 PIMs and it provides 88 physical ports (48 ports x 2) to MDF (PIM0 Slot LT8/AP4 used for PN- BS00). Table 2-3 Functional Outline of Installation Hardware INSTALLATION HARDWAREFUNCTIONAL NAMEFUNCTIONAL OUTLINE COVER PARTS TOP BOTTOM COVERBottom Cover (includes Top Cover) This hardware (bottom cover and top cover) is used for all NEAX1000 installations. A 4-rubber foot is required for desktop installation with PIM. 19” BRACKET 19” BRACKET19-inch Bracket The 19-inch bracket is sets of hardware to mount the PIM in IEC standard 19- inch rack. One set of 19-inch bracket is required for PIM.
CHAPTER 2 NDA-24219 Page 10 Revision 2.0 3.3 Functional Outline of Circuit Cards 3.3.1 Control Circuit Card Table 2-4 shows the functional outline of each control circuit cards. Table 2-4 Functional Outline of Control Circuit Cards CARD NAMEFUNCTIONAL NAMEFUNCTIONAL OUTLINE PN-CP03 MP Main Processor Card This card is equipped with Memory, TDSW (1024CH ´ 1024CH), 16-Line CFT, DTMF Sender, Clock, PLO (receiver mode 2 ports), RS-232C Ports (2 ports) for MAT/Built-in SMDR, modem for remote maintenance, and Music-On-Hold tone source (Melody IC/TNT), 4-circuit PBR (for PB calling or DID). This card is used on the basis of one per system. PZ-PW86 PWR Main Power Supply Card Input: AC 120 V (50 Hz/60 Hz) Output: –27 V (4.5 A), +5 V (7.5 A) One card is mounted in PIM. Note:This card does not provide ring generator or message wait volt- age. PZ-PW112 PWR Main Power Supply Card Input: AC 120 V (50 Hz/60 Hz) Output: –27 V (3.5 A), +5 V (4.0 A) One card is mounted in PIM. Note:This card does not provide ring generator or message wait volt- age. PN-BS00-B BS00 Bus Interface Card for PIM0 This card is equipped with functions of driver/receiver of various signals, functions of adjusting gate delay timing and cable delay timing, functions of monitoring I/O Bus and PCM Bus, and functions of controlling power supply. When the system consists of two PIMs, this card is mounted one in PIM0 PN-BS01-B BS01 Bus Interface Card for PIM1 This card is equipped with functions of driver/receiver of various signals, functions of adjusting gate delay timing and cable delay timing, functions of monitoring I/O Bus and PCM Bus, and functions of controlling power supply. When the system consists of two PIMs, this card is mounted one in PIM1. SPN-DAIB DAIB Firmware Processor-Bus Card—With T1 Used when installing PIM as a Remote PIM SPN-DAIC DAIC Firmware Processor-Bus Card—With T1 Used when installing PIM as a remote PIM expanded to 43 ports.
NDA-24219 CHAPTER 2 Page 11 Revision 2.0 3.3.2 Application Circuit Cards Table 2-5 shows the functional outline of each application circuit card. Table 2-5 Functional Outline of Application Circuit Cards CARD NAMEFUNCTIONAL NAMEFUNCTIONAL OUTLINE SPN-AP00-A AP00 Application Processor Card This card is equipped with four RS-232C ports, and is used for SMDR, H/M Printer, PMS functions and MCI. This card is used on the basis of one per system. SPN-AP01 AP01 Application Processor Card This card is equipped with one RS-232C port and one Ethernet interface port, and is used for OAI function. Also, this card is used to expand authorization code and ACD. This card is used on the basis of one per system. SPN-BRTA BRI Basic Rate (2B+D) Interface Trunk Card (S/T Interface) This card has one circuit of Basic Rate interface and provides one 2-channel PCM digital line. SPN-ME00 EXTMEM Memory Expansion Card This card is used with PN-AP00-A card for providing expansion memory. This card can be equipped with an expansions SRAM card (1MB) as SMDR data memory. SPN-CC00 ETHER Ethernet Control Card This card is used with the PN-AP01 card to accommodate the Ethernet, transmitting/ receiving a signal of TCP/IP protocol. SPN-CK00 PLO Phase Locked Oscillator Card This card is a phase locked oscillator for providing a synchronized clock signal with the network. This card is used when the PBX is a master office or when the PBX requires two clock supply routes and those frequencies differ. SPN-24DTA/ SPN-24DTA-ADTI Digital Trunk Interface (23B+D, 1.5 Mbps) Card This card accommodates 24-channel, PCM digital lines. SPN-4RSTB MFR 4-line MF Receiver Trunk card This card is used for MF Signaling on Digital DID trunks. A maximum of four cards can be provided per one system, including the PN-4RSTC card. SPN-4RSTC CIR 4-line CALLER ID Receiver Trunk Card This card is used for CALLER ID (CLASS SM) on analog trunks. A maximum of four cards can be provided per one system, including the PN-4RSTB card. SPN-SC00 CCH Common Channel Handler Card This card transmits/receives signals on the common signaling channel of No. 7 CCIS. SPN-SC01 DCH D-channel Handler Card This card transmits/receives signals on the D channel of ISDN Primary Rate (23B+D). SPN-SC02 ICH ISDN-channel Handler Card This card provides the D channel signaling interface and controls an ILC (Layer 2 and 3). Provides signaling interface for two ILCA cards.
CHAPTER 2 NDA-24219 Page 12 Revision 2.0 3.3.3 Line/Trunk Circuit Cards Table 2-6 shows the functional outline of each line/trunk circuit card. SPN-DAIA DAIA Firmware Processor Bus Card—With T1 Used in main system when connecting to Remote PIM SPN-DAIB. SPN-4RSTB- 911MF-911 Provides MF signaling for Enhanced 911. SPN-SC03 CSH Channel Handler for Zone Transceivers SPN-SC03 ICH ISDN-BRI Channel Handler Provides D-channel signaling interface for four ILCA cards. Table 2-6 Functional Outline of Line/Trunk Circuit Cards CARD NAMEFUNCTIONAL NAMEFUNCTIONAL OUTLINE PN-2AMPA AMP 2-line Amplifier Trunk Card This card equipped with the functions of Echo Canceller (EC), Automatic Gain Controller (AGC) and Tone Disabler (TD). PN-AUCA AUC 2-line Long-Line Circuit Card provided with the Power Failure Transfer (PFT) function line resistance in the case of a long-line circuit: Max. 2500 ohms (inclusive of the internal resistance of the distant office equipment) This card is internally equipped with a –48 V DC On-Board Power Supply. This card can also be used as a 2-line Direct Inward Dialing trunk card. PN-CFTA CFT Conference Trunk Card Use of one card:Can control a conference of up to six participants. Use of two cards:Can control a conference of up to ten participants. PN-4COTB COT 4-line Central Office Trunk Card (ground-start/loop-start trunk) equipped with the functions for loop detection, sending/detecting ground on Ring/Tip wire PN-4COTG COT 4-line Central Office Trunk Card (loop-start trunk) equipped with the functions for loop detection, receiving/sending the Caller ID (CLASS SM) signal PN-8COTM COT 8-line Central Office Trunk Card (loop-start trunk only) No loop disconnect detection is provided. PN-8COTP COT 8-line Central Office Trunk Card (loop-start trunk only) loop disconnect detection is provided. PN-2CSIA CSIA 2-Line Zone Transceiver Card PN-2DATA DAT 2-line Digital Announcement Trunk Card Duration: Max. 60 seconds. Table 2-5 Functional Outline of Application Circuit Cards (Continued) CARD NAMEFUNCTIONAL NAMEFUNCTIONAL OUTLINE
NDA-24219 CHAPTER 2 Page 13 Revision 2.0 PN-4DITB DIT 4-line Direct In-Dialing Trunk Card This card is equipped with the function for loop detection, sending reverse signal and PB to DP signal conversion. This card is internally equipped with –48 V DC On-Board Power supply. PN-DK00 DK Circuit card for External Relay Control/External Key Scan This card is provided with eight circuits, and can provide the above-mentioned control functions on a per circuit basis. PN-4DLCA/ PN-4DLCMDLC 4-line Digital Line Circuit card for Multiline Terminal Series E/Elite/Series III/ ElectraPro/DSS Console (–27 V Version, 2-wire type) Note This card is equipped with quick diagnostics to detect short line conditions and the normality (Synchronous/Asynchronous) of the terminal. PN-2DLCB/ PN-2DLCNDLC 2-line Digital Line Circuit Card for Multiline Terminal Series E/Series III/DSS Console/ DESKCON (–48V Version, 2-wire type) Note This card is equipped with quick diagnostics to detect short line conditions and normality (Synchronous/Asynchronous) of terminal. This card is internally equipped with a –48 V DC On-Board Power Supply. PN-2DLCC DLC 2-line Digital Line Circuit Card for Multiline Terminal Series II/SN610 Attendant Console (–48 V Version, 4-wire type) Note This card is equipped with quick diagnostics to detect short line conditions and the normality (Synchronous/Asynchronous) of the terminal. This card is internally equipped with –48 V On-Board Power Supply. PN-4DLCD/ PN-4DLCQDLC 4-line Digital Line Circuit Card exclusively used for Multiline Terminal Series E/Series III/DSS Console/DESKCON (–27 V Version, 2-wire type) Note This card is equipped with quick diagnostics to detect short line conditions and the normality (Synchronous/Asynchronous) of the terminal. PN-4DLCF DLC 4-line Digital Line Circuit Card for Multiline Terminal Series II/SN610 Attendant Console (–27 V Version, 4-wire type) Note This card is equipped with quick diagnostics to detect short line conditions. PN-8DLCJ/ PN-8DLCPDLC 8-line Digital Line Circuit Card for Multiline Terminal Series E/Series III/DSS Console/ DESKCON (–27 V Version, 2-wire type) Note PN-2DPCB DPC 2-line Data Port Controller Card This card is used for the intra-office or inter-office digital data transmission on fixed path connection. This card can accommodate a maximum of two DTE with V.11 (X.21) interface or V.24/V.28 (RS-232C) interface. PN-2ILCA ILC 2-line ISDN Line Circuit Card This card provides a physical interface to ISDN Terminals. PN-4LCD-A LC 4-line Analog Line Circuit Card for single line telephones Loop resistance: Max. 600 ohms This card is equipped with the function for controlling Message Waiting Lamp. Each 4 circuits are equipped with momentary open function. This card is equipped with quick diagnostics to detect short and open line conditions. This card is internally equipped with a +80 V DC-DC Power Supply circuit. Table 2-6 Functional Outline of Line/Trunk Circuit Cards (Continued) CARD NAMEFUNCTIONAL NAMEFUNCTIONAL OUTLINE
CHAPTER 2 NDA-24219 Page 14 Revision 2.0 PN-8LCS LC 8-line Analog Line Circuit Card for single-line telephones Loop resistance: Max. 600 W This card is equipped with a controller for momentary open function. PN-M03 M03 V.35 DTE Interface Card This card is used together with the PN-2DPCB card to provide the V.35 interface. PN-2ODTA ODT 2-line OD Trunk Card This card can be used as either a 2-wire E&M trunk or a 4-wire E&M trunk, and is internally equipped with a –48 V DC On-Board Power Supply. Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in one card. PN-PW00 PWR Provides -48V power for one DeskCon or two zone transceivers; maximum is 3 per system; uses two card slots PN-8RSTA PBR 8-line DTMF Receiver Card This card can be used for a DTMF station line, DID or tie line. PN-TNTA TNT 2-line Tone/Music Source interface Card This card is used for BGM or Music on Hold, and is equipped with two interface for an external tone/music source. PZ-VM00 4VM 4-Port Voice Mail Card (NEAX Mail AD-8) PZ-VM01 4VMEXT 4-Port Expansion Card for AD-8 (VM00) Note:The cable length between the DLC and terminal varies depending on the type of terminal. For the line conditions each terminal, refer to Table 2-7. Table 2-7 Line Condition of Each Terminals TERMINAL TYPE CARD TYPECABLE LENGTH (Cable 24AWG)REMARKS DTP-8-1 PN-8DLCJ / 8DLCP (STANDARD)984ft. (300m)Note 1 PN-4DLCD / 4DLCQ (STANDARD)984ft. (300m) [3937ft. (1200m)] PN-2DLCB / 2DLCN (LONG)2788ft. (850m) [3937ft. (1200m)] DTP-8D-1 PN-8DLCJ / 8DLCP (STANDARD)984ft. (300m)Note 1 PN-4DLCD / 4DLCQ (STANDARD)984ft. (300m) [3937ft. (1200m)] PN-2DLCB / 2DLCN (LONG)2788ft. (850m) [3937ft. (1200m)] Table 2-6 Functional Outline of Line/Trunk Circuit Cards (Continued) CARD NAMEFUNCTIONAL NAMEFUNCTIONAL OUTLINE
NDA-24219 CHAPTER 2 Page 15 Revision 2.0 DTP-16-1 PN-8DLCJ / 8DLCP (STANDARD)656ft. (200m)Note 1 PN-4DLCD / 4DLCQ (STANDARD)656ft. (200m) [3937ft. (1200m)] PN-2DLCB / 2DLCN (LONG)2788ft. (850m) [3937ft. (1200m)] DTP-16D-1 PN-8DLCJ / 8DLCP (STANDARD)656ft. (200m)Note 1 PN-4DLCD / 4DLCQ (STANDARD)656ft. (200m) [3937ft. (1200m)] PN-2DLCB / 2DLCN (LONG)2788ft. (850m) [3937ft. (1200m)] DTP-32-1 PN-8DLCJ / 8DLCP (STANDARD)656ft. (200m)Note 1 PN-4DLCD / 4DLCQ (STANDARD)656ft. (200m) [3937ft. (1200m)] PN-2DLCB / 2DLCN (LONG)2788ft. (850m) [3937ft. (1200m)] DTP-32D-1 PN-8DLCJ / 8DLCP (STANDARD)656ft. (200m)Note 1 PN-4DLCD / 4DLCQ (STANDARD)656ft. (200m) [3937ft. (1200m)] PN-2DLCB / 2DLCN (LONG)2788ft. (850m) [3937ft. (1200m)] DSS/BLF Console Note 2PN-8DLCJ / 8DLCP (STANDARD)984ft. (300m)Note 1 PN-4DLCD / 4DLCQ (STANDARD)984ft. (300m) PN-2DLCB / 2DLCN (LONG)2788ft. (850m) ETJ-8-1 PN-8DLCJ / 8DLCP (STANDARD)984ft. (300m)Note 1 PN-4DLCD / 4DLCQ (STANDARD)984ft. (300m) [3937ft. (1200m)] PN-2DLCB / 2DLCN (LONG)2788ft. (850m) [3937ft. (1200m)] ETJ-16DC-1 PN-8DLCJ / 8DLCP (STANDARD)656ft. (200m)Note 1 PN-4DLCD / 4DLCQ (STANDARD)656ft. (200m) [3937ft. (1200m)] PN-2DLCB / 2DLCN (LONG)2788ft. (850m) [3937ft. (1200m)] Table 2-7 Line Condition of Each Terminals (Continued) TERMINAL TYPE CARD TYPECABLE LENGTH (Cable 24AWG)REMARKS
CHAPTER 2 NDA-24219 Page 16 Revision 2.0 * The value in the [ ] shows the cable length when using the long line function. Note 1:When using PN-8DLCJ or PN-8DLCP card, it is not available long line function. Note 2:The DSS/BLF Console requires local AC/DC power supply. Note 3:With AC/DC power at DESKCON 3000’ with 4DLCD ETJ-16DD-1 PN-8DLCJ / 8DLCP (STANDARD)656ft. (200m) Note 1 PN-4DLCD / 4DLCQ (STANDARD)656ft. (200m) [3937ft. (1200m)] PN-2DLCB (LONG)2788ft. (850m) [3937ft. (1200m)] ETJ-24DS-1 PN-8DLCJ / 8DLCP (STANDARD)492ft. (150m) Note 1 PN-4DLCD / 4DLCQ (STANDARD)492ft. (150m) [3937ft. (1200m)] PN-2DLCB (LONG)2788ft. (850m) [3937ft. (1200m)] SN610 ATTCON PN-2DLCC (LONG)3937ft. (1200m) PN-4DLCF (STANDARD)984ft. (300m) DESKCON PN-4DLCD / 4DLCQ and PW00 or AC Adapter1500ft. (457m) Note 3 PN-8DLCJ / 8DLCP and PW00 or AC Adapter1000ft. (304m) Table 2-7 Line Condition of Each Terminals (Continued) TERMINAL TYPE CARD TYPECABLE LENGTH (Cable 24AWG)REMARKS