Page 61

Cl? 6270
Page 2 of 2VoiceMemo Release 6.OA and later
step
@XD Connect Modem
2.Connect the 9-pin cable connector to Serial port 2 (designated “S2” in the
VoiceMemo software).
3.Connect the 25pin cable connector to the modem. Configure the modem software
in the Console/Serial Port Setup option in the System Maintenance 
- Additional
Options Menu.
4.Test modem as recommended by the manufacturer’s documentation.
Reference
Dot. Fkv. A 

Page 62

Install Redundant Hard Diskcp 6284Page 1 of 3
VoiceMemo Release 6.OA and later
This procedure describes how to install a redundant hard disk in the Centigram Series 6
Model 70.
ADANGER!Disconnect the system from its power source before connecting
cables, components, or both.
CAUTION!Protect your system from ESD damage during handling of all
components.
z
Note:You can find TRs referenced in this procedure in the Centigram Series 6
StepTechnical Reference 
Manual.
Reference
@9 Observe Precautions
1.Put on...

Page 63

Cl? 6284
Page 2 of 3VoiceMemo Release 6.OA and later
Step
@3 Remove the Disk Carrier
WARNING!When the disk carrier is removed from the system, the power
switch terminals are accessible. These terminals can have
hazardous voltages present even when the power switch is turned
off. Unplug the system before performing the procedure. Failure
to do so can result in personal injury and/or equipment damage.
6. ‘Remove cabinet cover.
7.Disconnect the data and power cables from both the hard disk and the floppy...

Page 64

Cl? 6284
Page 3 of 3VoiceMemo Release 6.OA and later
Step
G9 Install the Redundant Hard Disk10. Remove the plastic faceplate cover from the top slot in the front of the empty hard
disk cage located next to the floppy disk drive.
11. Remove the aluminum faceplate cover from the top slot of the empty hard disk cage
12. Jumper the redundant hard disk as a slave (redundant) drive. If there are two hard
disks in one server, one must be configured as master and the other must be
configured as slave.Hard disks...

Page 65

--.
cp 6590Model 
70 InstallationPage 1 of 2VoiceMemo Release 6.OA and later
The Model 70 is 
preconfigured from the factory and ready to use. This procedure
provides guidelines on how to install the server. When using Centigram Procedures
(0s) referenced in this or any other procedures, disregard all instructions that apply to
other Series 6 server models.
WARNING!Observe all equipment safety and ESD precautions detailed in this
manual.
DANGER!To prevent injury either to yourself or others, follow QSHA...

Page 66

CT6590Page 2 of 2
Release 6.OA and later
steb10. Turn on the system and wait for initialization.
11. Run the Online System Verify of all records, and all speech and prompts.
12. Restart the server and wait for initialization.
13. Test basic telephony functions.14. If needed, connect an external modem to Serial port 2.(This connection requires a
null modem cable.)
15. Run a System Information Report and send it to the printer, if installed.
16. Examine the System Information Report and confirm that all...

Page 67

CP 7001Run Verify With System OnlinePage 1 of 4
VoiceMemo Release 6.OA and later
This procedure describes how to run an online system verify. An offline verify combines
verification of both account records and speech; in the online verify, it is possible to test
each category separately. To do a complete verify, all speech and all records must be
tested.
It is optional to log the results of the verify for use at a later time.
Since the server
responds differently based on whether the results are logged,...

Page 68

CIJ 7001
Page 2 of 4
VoiceMemo Release 6.OA and later
SteD
Select:(A) Verify All Records
(B) Verify Sibling Lists
(C) Verify Copy Lists
(D) Verify Distribution Lists
(M) Verify Mailboxes
(N) Verify 
AMIS Lists
(I’) Verify Phoneline Exceptions
or
(S) Verify Statistics Data
Response: The server displays dots while performing the verify, then returns to the
Record Verification Menu when done.
GDVerify Records Without logging Results
2.Access the Record Verification Menu and specify no logging of results....

Page 69

CP 7001
Page 3 of 4
VoiceMemo Release 6.OA and later
Step
3.Select the type(s) of records to verify. For standard maintenance of the server use
“Verify All Records.”If there is a specific problem with the server, select the
appropriate record type to be verified.
Select:(A) Verify Ail Records
(B) Verify Sibling Lists
(C) Verify Copy Lists
(D) Verify Distribution Lists
(M) Verify Mailboxes
(N) Verify 
AMIS Lists
(I?) Verify Phoneline Exceptions
or
(S) Verify Statistics Data
Response: The server displays...

Page 70

CP 7001
Page 4 of 4
VoiceMemo Release 6.OA and later
SteD
3.Select the type(s) of speech to verify. For standard maintenance of the server, use
“Verify All Speech and Prompts.”If there is a specific problem with the server,
select either speech or prompts to be verified.
Select:(A)Verify All Speech and Prompts
(P) Verify Prompts
or(S) Verify Speech
Response: The server displays dots while performing the verify, then returns to 
theSpeech Verification Menu when done.
CDVerify Speech Without logging...