Mitel Voice Processing Solutions Installation And Service Manual

Here you can view all the pages of manual Mitel Voice Processing Solutions Installation And Service Manual. The Mitel manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 51

Cl? 6215Page 2 of 2
VoiceMemo Release 6.OA and later
Step
Table 2 Printer Pin AssignmentsModel 70
Printer
(9-pi4(25pin)Signal Name
Pin 1Pin 4, Pin 5Carrier Detect
Pin 2Pin 20
Data Set Ready
Pin 3Pin 2Receive Data
Pin 4
Pin 8Request to Send. .
Pin 5’Pin 3Transmit Data
Pin 6Pin 8Clear to Send
Pin 7Pin 6Data Terminal Ready
Pin 8No connectionRing Indicate
Pin 9Pin 7Signal Ground
ED Connect Printer
3.Connect the 9-pin cable connector to Serial port 2 (designated “S2” in Model 70
software).4.Connect the...

Page 52

m6216Install ConsolePage 1 of 5
VoiceMemo Release 6.OA and later
This procedure tells you how to connect the console to the Model 70. It also provides
switch settings for the most popular terminals that are compatible with the Model 70.
For detailed console specifications, refer to the Centigram Series 6 Technical Reference
Manual.
The Model 70 can support a console equipped with a keyboard and a CRT or printer
display. You need a terminal to perform administrative and service operations.
SteD
Note:You...

Page 53

Cl? 6216
Page 2 of 5
VoiceMemo Release 6.OA and later
Step
@ED Verify Cabling Specifications2.Obtain the correct RS-232 cable for your terminal. Table 2 lists all signals present
at the serial port connectors.
Note:The Model 70 is shipped with a 9-pin D-type
female console cable which connects to the serial
port. The other end of this console cable is a 
25pinD-type female connector. To connect to a terminal,
personal computer, modem, or printer, you need an
RS-232 cable with a 
25pin D-type male...

Page 54

CP 6216
Page 3 of 5VoiceMemo Release 6.OA and later
GElB Verify Terminal Compatibility
3.Make sure that the customer’s terminal is one of the VT1 00-compatible terminals
listed in Tables 3 through 7, and set switches appropriately.
If the terminal is not listed in one of the following tables and it is VT1 
OO-compatible, consult the terminal’s documentation or TR 1928 in the Centigram
Series G Technical Reference Manual to determine switch settings.
Table 3 Zenith Z-19Note: Switches are located inside...

Page 55

Cl? 6216
Page 4 of 5
VoiceMemo Release 6.OA and latei
Table 5 TI Silent 703Note: Switches are located inside the cover latch.
1, 3,4Left (Open)
Note: Switches are located on the upper right corner.
Upper CaseOFF
Local copyOFF
Table 6 
DECwriter IV
SwitchSetting
VTNote. Swxches are located inside the top cover.
3,4,5,6UPNote: Set front panel switch to 300 baud.
Reference 

Page 56

Cl? 6216
Page 5 of 5VoiceMemo Release 6.OA and later
Table 7 
LSI ADM-3A
ParameterParameterBit 8 = 0Keyboard = Lower
Parity = Off
Linewrap = On
Stop Bits = 1Interface = RS-232C
Data Bits = 8Echo = FDX
Parity = Odd or EvenSpeed = 300 baud
Note: Switches are located inside the unit.
SPIADV = ADVPower = 60 Hz
Case = Upper or Lower
Lines/Screen = 24Keyboard Lock = DisableCursor Control = Enable
Clear Screen 
=EnableLocal = On
Protocols 103, 202 = OffCode = Off
Ext = OffEOT = Off
stepReference
@ Connect the...

Page 57

cp 6258Check Installation Quality
Page 1 of 1
VoiceMemo Release 6.OA and later
By following the steps below, you will be able to catch and correct all mistakes made
during the installation of the hardware.Most checks are visual and require only a few
minutes to complete.
SteD
CD Inspect Installation Quality
1.Check all internal cables and connectors to make sure that they are tight.
2.Check all peripheral cable connections to make sure they are properly labeled and
easily identifiable.
*.3. Check...

Page 58

cp 6261Connect the Telephone LinesPage 1 of 2
VoiceMemo Release 6.OA and later
This procedure provides guidelines on how to connect Model 120 or Model 70 ports to
the buildings main distribution frame (MDF).Consult Appendix A of your 
Systeem
Implementation Guide before using this procedure.
WARNING!Work closely with your project manager to prevent accidental
interruption to your telephone services.
StepReference
@D Use Correct Jackss,
1.The ports on the Model 120 or Model 70 line cards have RJ-45...

Page 59

Cl.? 6261Page 2 of 2
VoiceMemo Release 6.OA and later
SteD
@D Connect Telephone Lines
5.Ask you project manager where the MDF is situated. The MDF is usually situated
in a closet or storage room of the building.
6.Have the worksheets available that show the Model 120 or Model 70 line groups
you plan to configure. Make a list of the telephone numbers and their
corresponding Model 120 or Model 70 ports.
7.Mount the necessary number of RJ-45 modular connector blocks near the Model
120 or Model 70.z...

Page 60

cr 6270
Install ModemPage 1 of 2
VoiceMemo Release 6.OA and later
This procedure explains how to connect a modem to the Model 120 or Model 70.
StepRefireme
@D Verify Cabling Specifications
1.Obtain the correct RS-232 cable for your modem. Table 2 lists all signals present at
the serial port connectors.
Note:The Model 120 is shipped with a 9-pin D-type female console cable
which connects to serial port 2. The other end of this console cable is
a 
25pin D-type female connector.To connect to a terminal,...