    Have a look at the manual Mitel Sx-2000 Integrated Communications System Control Sheet Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 526
    							Important Safety Instructions 
    Table 1-7 SX-2000 SG System Sub-assemblies 
    (continued) 
    Page 2 of 3 
    9125-060-203-NA Issue 1 
    Revision 0 203 l-27  
    						
    							Safety instructions 
    Table 1-7 SX-2000 SG System Sub-assemblies 
    (continued) 
    Marketing Number 
    Description / Common Name Engineering Minimum 
    Number Revision 
    MM080BA 
    FILTER HOUSING 1070806BA A 
    MM082AA CABLE TROUGH KIT 1 1070826AA A 
    MM089AB FILLER CARD 132887501 B 
    MM136AA CABLE DUCT 1071366AA A 
    MP91 OFA CONTROL CONVERTER II 1079106FA A 
    MPSllCA PERIPHERAL CONVERTER 1079116CA A 
    MP912BA DC CONVERTER 1255493BA A 
    MK149AA ROOF SCREEN ASSEMBLY 134336601 A 
    Page 3 of 3 
    Note: DSUs listed in Table l-11 and PlCs listed in Table l-l 2 are also suitable for use in the SX-ZOOOSG system. 
    203 l-28 Revision 0 912!j-O60-203-NA Issue 1  
    						
    							Important Safety Instructions 
    Table l-8 SX-2000 S System Sub-assemblies 
    I I I 
    MA308AA 1 CEPT INTERFACE ASSEMBLY 
    1 1210563AA A 
    I 
    MA309AA 
    DS-1 INTERFACE ASSEMBLY 1202623AA A 
    MA31 OAA SYSTEM ID MODULE 121060601 B 
    MA320AA CONTROL CABINET 133182601 A 
    I 
    I I 
    MA321AA 1 PERIPHERAL CABINET 1 133186601 A 
    I 
    2nd CABINET CONTROL COMMUNICATION KIT 
    I I 
    MP914AA 1 AC CONVERTER 1258033AA 1 3 
    I 
    Note: DSUs listed in Table l-l 1 and PlCs listed in Table l-l 2 are also suitable for use in the SX-2000 S system. 
    9125-06&203-NA Issue 1 
    Revision 0 203 l-29  
    						
    							Safety Instructions 
    Table l-9 SX-2000VS System Sub-assemblies 
    MP912BA DC CONVERTER 1255493BA A 
    MP914AA AC CONVERTER 1258033AA 3 
    Note: DSUs listed in Table l-11 and PlCs listed in Table l-l 2 are also suitable for use in the SX-ZOffOVS system. 
    203 l-30 
    Revision 0 9125-060-203-NA Issue 1  
    						
    							Important Safety Instructions 
    Table I-10 SX-2UUO FD System Sub-assemblies 
    Note: DSUs listed in Table 1-11 and PlCs listed in Table 1-12 are also suitable for use in the SX-2000 FD system. 
    912546&203-NA Issue 1 Revision 0 203 l-31  
    						
    							Safety Instructions 
    I Table I-11 Digital Service Unit (DSU) Cards 
    Marketing 
    Description / Common Name Engineering Minimum 
    Number Number Revision 
    MC260AA CONFERENCE 
    1072603AA A 
    1 MC262AA ( ADVANCE TONE DETECTOR 
    1 1072623AA 1 B 1 
    MC263AA 1 DS-1 FORMATTER 
    I I 
    1 1072633AA 1 B 
    1 
    MC264AA CEPT FORMATTER 1072643AA B 
    MC265AA DATA TRANSCEIVER (SEE NOTE) 1072653AA A 
    MC266AA 1 COMMUNICATION PROCESSOR 
    ‘Note: Not used in the SX-2000 FD system. 
    1072663AA 4 
    I 
    Table 1-12 Peripheral Interface Circuit (PIC) Cards 
    < MC341CA DID/LOOP TIE TRUNK 1073413CA C 
    MC342BB E&M TRUNK 107342388 D 
    MC380AA DTMF RECEIVER 1073803AA B 
    Note: Only used in the SX-2000 SG system. 
    203 l-32 
    Revision 0 912!!+060-203-NA Issue 1  
    						
    							Important Safety Instructions 
    Installation of Telecommunications Wiring 
    1.7 Telecommunications wiring to this product shall conform to all applicable safety and 
    electrical wiring regulations. Installation of telecommunications wiring shall be 
    performed following precautions in accordance with standard industry practice. The 
    precautions to be followed include: 
    1. Never install telephone wiring during a lightning storm. 
    2. Never install telephone jacks in wet locations unless the jack is specifically de- 
    signed for wet locations. 
    3. Never touch uninsulated telephone wires or terminals unless the telephone line has 
    been disconnected at the network interface. 
    4. Use caution when installing or modifying telephone lines. 
    5. To ensure isolation between cabinets, metal sheathing should not be used on fiber 
    cables connecting the SX-2000 FD Control, Peripheral, and DSU cabinets. Con- 
    duit may be used to encase fiber cabling, provided the conduit does not contact the 
    cabinets. 
    6. The SFT (System Fail Transfer) output connector on an SX-2000 FD system Pe- 
    ripheral Node (see Figure 1-14) shall not be connected to an off-premise 
    application. 
    I Any connection of the assemblies listed below to an outside plant lead, an off- 
    - premise application or any other exposed plant application may result in a fire 
    or shock hazard, and/or defective operation and/or equipment damage. 
    Table 1-13 Restricted Peripheral Interface Circuit Cards 
    Marketing Number Description / Common Name 
    MC320BE ONS LINE CARD 
    I I MC330AA 1 DNI LINE CARD 
    I 
    I MC324AA 1 DATASET LINE CARD 
    I 
    MC323BA COV LINE CARD 
    MC263AA DS-1 FORMAlTER CARD 
    MC264AA CEPT FORMAlTER CARD 
    I MC322BB 1 HIGH SPEED DIGITAL LINE CARD 
    I 
    9125-06&203-NA Issue 1 
    Revision 0 203 l-33  
    						
    							Safety Instructions 
    Examples of installations which shall not be permitted for connection to these interfaces 
    are those which: 
    (a) Require protectors in accordance with the National Electrical Code for the United 
    States, NEC, NFPA / ANSI 70, Article 800-30, or, 
    (b) Are “Exposed Plant” as defined in the Canadian Electrical Code -CSA C22.1, para- 
    graph 60-I 00 which states; “Exposed plant means where any portion of the circuit 
    is subject to accidental contact with electric lighting or power conductors operating 
    at a voltage exceeding 300V between conductors or is subject to lightning strikes.” 
    Note: The 
    DS-1 Formatter and the CEPT Formatter cards may be connected to an outside plant 
    lead, an off-premise application or any other exposed plant lead only through a device 
    that has been suitably investigated and approved for those network conditions. 
    203 l-34 Revision 0 
    9125-060-203-NA Issue 1  
    						
    							SX-2000s INTEGRATED 
    COMMUNICATIONS SYSTEM 
    Commissioning 
    la 
    AtoZ KELLATRONICS, INC 
    I 
    TM, @-Trademark ol MM Corpomtlon. 
    0 CopyrIght WBZ, MM CorponUon. 
    All rights resewed. 
    PrInted In Canada 
    a MITE2  
    						
    							ii NOTICE 
    The information contained in this document is believed to be accurate in all re- 
    spects but is not warranted by Mite1 Corporation (MITELB). The information is 
    subject to change without notice and should not be construed in any way as a 
    commitment by Mite1 or any of its affiliates or subsidiaries. Mite1 and its affiliates 
    and subsidiaries assume no responsibility for any errors or omissions in this doc- 
    ument. Revisions of this document or new editions of it may be issued to incor- 
    porate such changes. 
    VTIOO” is a trademark of Digital Equipment Corp.  Commissioning 
    Revision 0 912!3-060-204-NA Issue 1  
    						