SX-2000@ INTEGRATED COMMUNICATIONS SYSTEM Safety Instructions I”, @ -1rademarlc ol MM Corpomtlon. 0 copyrlgm 1992. Mltel colporauon. All rights reserved. Printed In Canada 0 MlTEL@

Safety Instructions NOTICE The information contained in this document is believed to be accurate in all re- spects but is not warranted by Mite1 Corporation (MITEL@). The information is subject to change without notice and should not be construed in any way as a commitment by MITEL or any of its affiliates or subsidiaries. MITEL and its affili- ates and subsidiaries assume no responsibility for any errors or omissions in this document. Revisions of this document or new editions of it may be issued to in- corporate such changes. ii Revision 0 912!5-060-203-NA Issue 1

Table of Contents 1. IMPORTANT SAFETY INSTRUCTIONS General ................................................................... 203 l-l Useof Notices ............................................................. 203 l-2 UseofSymbols ............................................................ 203 l-2 General Installation Summary ................................................. 203 l-3 Fuse and Component Replacement ............................................. 203 l-3 Identification and Location of Circuit Cards for Installation ............................ 203 l-4 EquipmentGrounding ........................................................ 203 l-9 General Description ...................................................... 203 l-9 SX-20008 SG Grounding ................................................. 203 l-10 SX-2OOOSGrounding.. .................................................. 203 1-16 SX-ZOOOVSGrounding ................................................... 203 l-23 SX-ZOOOFDGrounding ................................................... 203 l-26 Approved Configurations of Product (United States of America) ....................... 203 l-26 Installation of Telecommunications Wiring ........................................ 203 l-33 Figure l-l SX-2000 VS System Circuit Card Locations ........................... 203 l-4 Figure l-2 SX-2000 S System Circuit Card Locations ............................ 203 l-5 Figure l-3 SX-2000 SG System Circuit Card Locations ........................... 203 l-6 Figure l-4 SX-2000 FD System Circuit Card Locations in the Control Node ........... 203 l-7 Figure l-5 SX-2000 FD System Circuit Card Locations in the Peripheral and DSU Nodes 203 l-6 Figure l-6 SX-2000 SG System Ground Connections ............................ 203 l-13 Figure l-7 SX-2000 SG Control Backplane .................................... 203 l-l 4 Figure l-6 SX-2000 SG Peripheral Backplane .................................. 203 l-15 Figure 1 Figure 1 - Figure 1 Figure 1 Figure 1 Figure 1 List of Figures -9 SX-2000 S System Ground Connections ............................. 203 l-19 -10 SX-2000 S System AC and DC Power Distribution Units (Rear Panel) ...... 203 l-20 -11 SX-2000 S System AC Power Distribution Unit Terminal Blocks ........... 203 l-21 -12 SX-2000 S System DC Power Distribution Unit Terminal Blocks ........... 203 l-22 -13 SX-2000 VS System Grounds ...................................... 203 l-24 -14 SX-2000 FD System Grounds ...................................... 203 l-25 List of Tables Table l-l Control Cabinet Grounding Cables (SX-2000 SG System) ............... ,203 l-l 0 Table l-2 Peripheral Cabinet Grounding Cables (SX-2000 SG System) ............ .203 l-l 2 Table l-3 AC Systems Grounding Cables (External) ........................... .203 l-l 7 9125-060-203-NA Issue 1 Revision 0 . . . III

Safety Instructions Table l-4 DC System Grounding Cables (External) ............................. 203 l-l 8 Table l-5 SX-2000 VS System Cabinet Grounding Cables (External) .............. ,203 l-23 Table l-6 SX-2000 FD System Peripheral Cabinet Grounding Cables (External) ....... 203 l-26 Table l-7 SX-2000 SG System Sub-assemblies .............................. ,203 l-26 Table l-8 SX-2000 S System Sub-assemblies ................................. 203 l-29 Table l-9 SX-2OOOVS System Sub-assemblies ............................... ,203 I-30 Table l-l 0 SX-2000 FD System Sub-assemblies ............................... 203 l-31 Table l-11 Digital Service Unit (DSU) Cards ................................... ,203 l-32 Table l-12 Peripheral Interface Circuit (PIC) Cards ............................... 203 l-32 Table l-13 Restricted Peripheral Interface Circuit Cards ........................... 203 l-33 iv Revision 0 9126-060-203-NA Issue 1

IMPORTANT SAFETY INSTRUCTIONS These instructions are intended as a general guide to provide basic installation information which is necessary for the proper and safe functioning of this equipment. 1 WARNING ) Failure to follow all instructions may result in improper equipment operation and/or risk of electrical shock. General l Read and understand all instructions, Keep these instructions with the equipment. l Do not attempt to install or service this equipment unless you are skilled in the instal- lation and maintenance of electronic telecommunications equipment and have successfully completed specific training for this equipment. l This product must be installed and serviced in accordance with this document and the information contained in this set of Technical Practices. Practice 9125-060-01 I-NA, Control Sheet, is the Practice Index document. l Follow all procedures outlined in the practices in the sequence that is given. l Install all assemblies using the procedures described in Practice 912X-060-200--NA, Installation. Note: Practice numbers vary according to the particular product variant, i.e., 9120-06&200-NA - Installation practice number for the SX-20008 SG system 9121-060-20&NA - Installation practice number for the SX-2000 S system 9123-060-20&NA - Installation practice number for the SX-2000 VS system 9124-06&20&NA - Installation practice number for the SX-2000 FD system l Configure this product with only the assemblies specified and in the locations stated in this set of Technical Practices. l Replace all guards or barriers. Close and lock doors at the completion of installation or before returning the equipment to service. l Grounding circuit continuity is vital for safe operation of telecommunications equip- ment. Never operate telecommunications equipment with the grounding conductor disconnected. e Ensure grounding conductor is installed before connecting telecommunications cabling to any system. 9 12!5-060-203-NA Issue 1 Revision 0 203 l-l

Safety Instructions Use of Notices 1.1 The following information provides an explanation of the notices which appear on the product and in the practices for this product: DANGER WARNING CAUTION Danger indicates an imminently hazardous situation which, if not avoided will result in death or serious injury. Warning indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Caution indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury and/or damage to the equipment or property. Use of Symbols 1.2 The following information provides an explanation of the symbols which appear on the product: The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure DANGEROUS VOLTAGE that may be of sufficient magnitude to constitute a significant risk of electric shock to persons. A A The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and l maintenance (servicing) instructions in the literature INSTRUCTIONS accompanying the product. Q I PROTECTIVE GROUNDING TERMINAL The ground symbol within a circle identifies the terminal which is intended for connection to an external protective conductor. This connector must be connected to earth ground prior to making any other connections to the equipment. 203 l-2 Revision 0 9125-060-203-NA Issue 1

Important Safety Instructions General Installation Summary Power Source This product is intended to operate from an electrical source rated as indicated below. Each cabinet shall be powered from a separate branch circuit wired in accordance with the National Electrical Code or the Canadian Electrical Code, as applicable. SX-2000 SG -48 Vdc 6OA sx-2000 s -48 Vdc 25A 120 Vat 15A 60 Hz SX-2000 VS -48 Vdc 15A 120 Vat 15A 60 Hz SX-2000 FD 120 Vat 15A 60 Hz Equipment Location This product shall only be situated in a clean and dry environment in accordance with the environmental and other installation requirements specified in Practice 912X-O6&2004A, Installation. Cabinet Installation The SX-2000 VS cabinet is equipped with castors and leveling feet. Once the cabinet has been positioned, lock the front castors and lower leveling feet as required to stabilize cabinet. 4C Power Cord Use only the 3 -wire ac power cord supplied with this product. >ower Distribution Cables Refer to 912X-060-20&NA, Installation, for details on installation of power distribution cables. Fuse and Component Replacement Unauthorized repair of this product may result in a fire or shock hazard, and/or defective operation and/or equipment damage. Do not repair or replace compo- nents on circuit card assemblies or other parts of this equipment unless there is a specific description of the procedure provided in this set of technical prac- tices. Return all inoperative assemblies to an authorized mite1 agent for repair. 1.3 Fuses identified with an electrical rating (voltage, current, type) shall be replaced with only the same type and rating. Never replace fuses with devices having different electrical ratings. Only those fuses installed in fuse-clips or fuse-holders shall be replaced in the field as directed by instructions in this set of Technical Practices. Do not replace or attempt to bypass soldered-in fuses on circuit card assemblies. Refer to the appropriate documents in this document set for information on the proper method of troubleshooting and servicing of this product. Practice 9126-060-011 -NA, Control Sheet, is the Practice Index document. 9125-06&203-NA Issue 1 Revision 0 203 l-3

Safety Instructions Identification and location of Circuit Cards for Installation 1.4 The mechanical design consists of a metal enclosure, a card cage, and an interconnecting backplane which define the arrangement and position ofcircuit card assemblies. Installation of a circuit card assembly is performed by sliding it along the card cage guides in the appropriate slot until the card is firmly seated into the mating connector on the backplane. Refer to Figure 1-I through Figure 1-5 for the specific locations of circuit cards. * NOTES: 1) If 15 PlCs 818 used, lhm anly DSU 1 may be i&&d. 2) H DSU 1 and DSU 2 81e required, then PIG 15 must not be itilled. 3) If DSU 1, DSUPand DSU 3arerequbed,tkn PIC 13, PIG 14and PIC 15mustnatbeimteled. 4) RefertoTablel-11, DSUsendTable l-12, PlCsfor fistsofepproved cads. 203 l-4 Revision 0 912!5-060-203-NA Issue 1 Figure l-l SX-2000VS System Circuit Card Locations

Important Safety Instructions (A)UPPERSHELF-SHELF2 1 2 3 4 5 6 7 6 9 10 11 12 13 14 15 16 17 16 19 20 (B)LOMRSHELF-SHELF1 1 2 3 4 5 6 7 6 9 10 11 12 13 14 15 16 17 16 19 20 * * * * * * NOES: 1. The minbnum system musthavethe cardsindicated by* installed In slots as shown. 2. 3. RefertoTsble l-11, DSUs andTable 1-12, Pit&for lists of approved cards. Ocmtd Fl4M II cad not required with Main Cotifflec II card. Figure l-2 SX-2000 S System Circuit Card Locations 9125-060-203-NA Issue 1 Revision 0 203 15

Safety Instructions (A) PERIPHERALSHELF 123456 7 6 9 10 11 12 13 14 15 16 17 16 19 20 21 22 23 24 25 26 27 26 29 30 31 32 33 *** * I PERIPHERALINTERFACE CARDS I I I I PERIPHEIWL SWKCH (B) COFrmOLSHELF 1 2 3 4 5 6 7 6 9 10 11 12 13 14 15 16 17 16 19 20 21 22 23 24 25 26 27 26 29 30 31 32 33 I MAIN CONTROLCOMPLE% I I I MESSAGE SWilCH CIRCUIT SWITCH DIGITALSERWCE UNrCS NOTE: RefettoTablel-11, DSUsandTable l-12, PlCqfaklsof approved cards 203 l-6 Figure l-3 SX-2000 SG System Circuit Card Locations Revision 0 9125-060-203-NA Issue 1